Ion-selective electrodes using carbon nanotubes as ion-to-electron transducers GA Crespo, S Macho, FX Rius Analytical chemistry 80 (4), 1316-1322, 2008 | 481 | 2008 |
Wearable potentiometric ion sensors M Parrilla, M Cuartero, GA Crespo TrAC Trends in Analytical Chemistry 110, 303-320, 2019 | 317 | 2019 |
Transduction mechanism of carbon nanotubes in solid-contact ion-selective electrodes GA Crespo, S Macho, J Bobacka, FX Rius Analytical chemistry 81 (2), 676-681, 2009 | 263 | 2009 |
Potentiometric sensors using cotton yarns, carbon nanotubes and polymeric membranes T Guinovart, M Parrilla, GA Crespo, FX Rius, FJ Andrade Analyst 138 (18), 5208-5215, 2013 | 235 | 2013 |
Paper based ion-selective potentiometric sensors M Novell, M Parrilla, GA Crespo, FX Rius, FJ Andrade Analytical chemistry 84 (11), 4695-4702, 2012 | 235 | 2012 |
Photocurrent generation based on a light-driven proton pump in an artificial liquid membrane X Xie, GA Crespo, G Mistlberger, E Bakker Nature chemistry 6 (3), 202-207, 2014 | 184 | 2014 |
Wearable all-solid-state potentiometric microneedle patch for intradermal potassium detection M Parrilla, M Cuartero, S Padrell Sánchez, M Rajabi, N Roxhed, F Niklaus, ... Analytical chemistry 91 (2), 1578-1586, 2018 | 181 | 2018 |
A reference electrode based on polyvinyl butyral (PVB) polymer for decentralized chemical measurements T Guinovart, GA Crespo, FX Rius, FJ Andrade Analytica chimica acta 821, 72-80, 2014 | 174 | 2014 |
Recent advances in ion-selective membrane electrodes for in situ environmental water analysis GA Crespo Electrochimica Acta 245, 1023-1034, 2017 | 167 | 2017 |
Epidermal patch with glucose biosensor: pH and temperature correction toward more accurate sweat analysis during sport practice A Wiorek, M Parrilla, M Cuartero, GA Crespo Analytical chemistry 92 (14), 10153-10161, 2020 | 163 | 2020 |
Efficient BiVO4 Photoanodes by Postsynthetic Treatment: Remarkable Improvements in Photoelectrochemical Performance from Facile Borate Modification Q Meng, B Zhang, L Fan, H Liu, M Valvo, K Edström, M Cuartero, ... Angewandte Chemie 131 (52), 19203-19209, 2019 | 163 | 2019 |
Lactate biosensing for reliable on-body sweat analysis X Xuan, C Perez-Rafols, C Chen, M Cuartero, GA Crespo ACS sensors 6 (7), 2763-2771, 2021 | 160 | 2021 |
All-solid-state potentiometric sensors with a multiwalled carbon nanotube inner transducing layer for anion detection in environmental samples D Yuan, AHC Anthis, M Ghahraman Afshar, N Pankratova, M Cuartero, ... Analytical chemistry 87 (17), 8640-8645, 2015 | 149 | 2015 |
Wearable potentiometric sensors for medical applications M Cuartero, M Parrilla, GA Crespo Sensors 19 (2), 363, 2019 | 142 | 2019 |
Wearable potentiometric ion patch for on-body electrolyte monitoring in sweat: toward a validation strategy to ensure physiological relevance M Parrilla, I Ortiz-Gómez, R Cánovas, A Salinas-Castillo, M Cuartero, ... Analytical chemistry 91 (13), 8644-8651, 2019 | 139 | 2019 |
All-solid-state potentiometric sensors: A new wave for in situ aquatic research M Cuartero, GA Crespo Current Opinion in Electrochemistry 10, 98-106, 2018 | 138 | 2018 |
Ionophore-based optical sensors G Mistlberger, GA Crespo, E Bakker Annual review of analytical chemistry 7 (1), 483-512, 2014 | 124 | 2014 |
Nanostructured materials in potentiometry A Düzgün, GA Zelada-Guillén, GA Crespo, S Macho, J Riu, FX Rius Analytical and bioanalytical chemistry 399, 171-181, 2011 | 118 | 2011 |
Modern creatinine (Bio) sensing: Challenges of point-of-care platforms R Cánovas, M Cuartero, GA Crespo Biosensors and Bioelectronics 130, 110-124, 2019 | 116 | 2019 |
Potentiometric strip cell based on carbon nanotubes as transducer layer: Toward low-cost decentralized measurements FX Rius-Ruiz, GA Crespo, D Bejarano-Nosas, P Blondeau, J Riu, FX Rius Analytical chemistry 83 (22), 8810-8815, 2011 | 116 | 2011 |