High-stability transfer of an optical frequency over long fiber-optic links PA Williams, WC Swann, NR Newbury
Journal of the Optical Society of America B 25 (8), 1284-1293, 2008
419 2008 Coherent transfer of an optical carrier over NR Newbury, PA Williams, WC Swann
Optics letters 32 (21), 3056-3058, 2007
282 2007 Rotating-wave-plate Stokes polarimeter for differential group delay measurements of polarization-mode dispersion PA Williams
Applied optics 38 (31), 6508-6515, 1999
248 1999 Temperature dependence of the Verdet constant in several diamagnetic glasses PA Williams, AH Rose, GW Day, TE Milner, MN Deeter
Applied Optics 30 (10), 1176-1178, 1991
198 1991 Rotating-polarizer polarimeter for accurate retardance measurement PA Williams, AH Rose, CM Wang
Applied optics 36 (25), 6466-6472, 1997
138 1997 Optical, thermo-optic, electro-optic, and photoelastic properties of bismuth germanate (Bi4 Ge3 O12 ) PA Williams, AH Rose, KS Lee, DC Conrad, GW Day, PD Hale
Applied Optics 35 (19), 3562-3569, 1996
135 1996 The causal relationship between melt pool geometry and energy absorption measured in real time during laser-based manufacturing BJ Simonds, J Tanner, A Artusio-Glimpse, PA Williams, N Parab, C Zhao, ...
Applied Materials Today 23, 101049, 2021
88 2021 Time-resolved absorptance and melt pool dynamics during intense laser irradiation of a metal BJ Simonds, J Sowards, J Hadler, E Pfeif, B Wilthan, J Tanner, C Harris, ...
Physical review applied 10 (4), 044061, 2018
83 2018 Fundamental limits in fiber Bragg grating peak wavelength measurements SD Dyer, PA Williams, RJ Espejo, JD Kofler, SM Etzel
17th International Conference on Optical Fibre Sensors 5855, 88-93, 2005
81 2005 Portable, high-accuracy, non-absorbing laser power measurement at kilowatt levels by means of radiation pressure P Williams, J Hadler, F Maring, R Lee, K Rogers, B Simonds, M Spidell, ...
Optics Express 25 (4), 4382-4392, 2017
67 2017 Use of radiation pressure for measurement of high-power laser emission PA Williams, JA Hadler, R Lee, FC Maring, JH Lehman
Optics Letters 38 (20), 4248-4251, 2013
54 2013 Large electroclinic effect in new liquid crystal materiala PA Williams, NA Clark, MB Ros, DM Walba, MD Wand
Ferroelectrics 121 (1), 143-146, 1991
51 1991 PMD measurement techniques and how to avoid the pitfalls P Williams
Journal of Optical and Fiber Communications Reports 1 (1), 84-105, 2004
44 2004 Modulation phase-shift measurement of PMD using only four launched polarisation states: a new algorithm PA Williams
Electronics letters 35 (18), 1578-1579, 1999
43 1999 Frequency characterization of a swept-and fixed-wavelength external-cavity quantum cascade laser by use of a frequency comb K Knabe, PA Williams, FR Giorgetta, CM Armacost, S Crivello, ...
Optics express 20 (11), 12432-12442, 2012
39 2012 Comparison of electrostatic and photon pressure force references at the nanonewton level GA Shaw, J Stirling, J Kramar, P Williams, M Spidell, R Mirin
Metrologia 56 (2), 025002, 2019
37 2019 Corrections to fixed analyzer measurements of polarization mode dispersion PA Williams, CM Wang
Journal of lightwave technology 16 (4), 534, 1998
36 1998 Design and performance of a stable linear retarder KB Rochford, AH Rose, PA Williams, CM Wang, IG Clarke, PD Hale, ...
Applied optics 36 (25), 6458-6465, 1997
36 1997 X-ray observation of electroclinic layer constriction and rearrangement in a chiral smectic-A liquid crystal AG Rappaport, PA Williams, BN Thomas, NA Clark, MB Ros, DM Walba
Applied physics letters 67 (3), 362-364, 1995
34 1995 Absolute spectroscopy of N2 O near 4.5 μm with a comb-calibrated, frequency-swept quantum cascade laser spectrometer K Knabe, PA Williams, FR Giorgetta, MB Radunsky, CM Armacost, ...
Optics express 21 (1), 1020-1029, 2013
31 2013