Estimating the impact of indoor relative humidity on SARS-CoV-2 airborne transmission risk using a new modification of the Wells-Riley model A Aganovic, Y Bi, G Cao, F Drangsholt, J Kurnitski, P Wargocki Building and environment 205, 108278, 2021 | 88 | 2021 |
A systematic review of operating room ventilation S Sadrizadeh, A Aganovic, A Bogdan, C Wang, A Afshari, A Hartmann, ... Journal of Building Engineering 40, 102693, 2021 | 80 | 2021 |
Do surgeons and surgical facilities disturb the clean air distribution close to a surgical patient in an orthopedic operating room with laminar airflow? G Cao, MCA Storås, A Aganovic, LI Stenstad, JG Skogås American Journal of Infection Control 46 (10), 1115-1122, 2018 | 67 | 2018 |
Impact of surgical lights on the velocity distribution and airborne contamination level in an operating room with laminar airflow system A Aganovic, G Cao, LI Stenstad, JG Skogås Building and Environment 126, 42-53, 2017 | 62 | 2017 |
CFD study of the air distribution and occupant draught sensation in a patient ward equipped with protected zone ventilation A Aganovic, M Steffensen, G Cao Building and Environment 162, 106279, 2019 | 52 | 2019 |
New dose-response model and SARS-CoV-2 quanta emission rates for calculating the long-range airborne infection risk A Aganovic, G Cao, J Kurnitski, P Wargocki Building and Environment 228, 109924, 2023 | 32 | 2023 |
Evaluation of airborne contaminant exposure in a single-bed isolation ward equipped with a protected occupied zone ventilation system A Aganovic, G Cao Indoor and built environment 28 (8), 1092-1103, 2019 | 31 | 2019 |
Cost-related analysis of implementing energy-efficient retrofit measures in the residential building sector of a middle-income country–A case study of Bosnia and Herzegovina D Kadrić, A Aganovic, S Martinović, N Delalić, B Delalić-Gurda Energy and Buildings 257, 111765, 2022 | 30 | 2022 |
Experimental study of the interaction between thermal plumes and human breathing in an undisturbed indoor environment Z Cheng, C Guangyu, A Aganovic, L Baizhan Energy and Buildings 207, 109587, 2020 | 30 | 2020 |
Modeling the impact of indoor relative humidity on the infection risk of five respiratory airborne viruses A Aganovic, Y Bi, G Cao, J Kurnitski, P Wargocki Scientific Reports 12 (1), 11481, 2022 | 27 | 2022 |
Ventilation design conditions associated with airborne bacteria levels within the wound area during surgical procedures: a systematic review A Aganovic, G Cao, T Fecer, B Ljungqvist, B Lytsy, A Radtke, ... Journal of Hospital Infection 113, 85-95, 2021 | 27 | 2021 |
Post-COVID ventilation design: infection risk-based target ventilation rates and point source ventilation effectiveness J Kurnitski, M Kiil, A Mikola, KV Vosa, A Aganovic, P Schild, O Seppänen Energy and Buildings 296, 113386, 2023 | 24 | 2023 |
Multi-objective optimization of energy-efficient retrofitting strategies for single-family residential homes: Minimizing energy consumption, CO2 emissions and retrofit costs D Kadrić, A Aganović, E Kadrić Energy Reports 10, 1968-1981, 2023 | 20 | 2023 |
Experimental and simulated evaluations of airborne contaminant exposure in a room with a modified localized laminar airflow system Z Cheng, A Aganovic, G Cao, Z Bu Environmental Science and Pollution Research 28, 30642-30663, 2021 | 19 | 2021 |
Experimental study on the exposure level of surgical staff to SARS-CoV-2 in operating rooms with mixing ventilation under negative pressure Y Bi, A Aganovic, HM Mathisen, G Cao Building and Environment 217, 109091, 2022 | 16 | 2022 |
Zonal modeling of air distribution impact on the long-range airborne transmission risk of SARS-CoV-2 A Aganovic, G Cao, J Kurnitski, A Melikov, P Wargocki Applied Mathematical Modelling 112, 800-821, 2022 | 15 | 2022 |
Analysis of parameters influencing pathogen concentration in a room with displacement ventilation using computational fluid dynamics and Taguchi methods BE Yuce, A Aganovic, PV Nielsen, P Wargocki Journal of Building Engineering 80, 108002, 2023 | 13 | 2023 |
An experimental study on the effects of positioning medical equipment on contaminant exposure of a patient in an operating room with unidirectional downflow A Aganovic, G Cao, LI Stenstad, JG Skogås Building and Environment 165, 106096, 2019 | 13 | 2019 |
Applying the response surface methodology to predict the energy retrofit performance of the TABULA residential building stock D Kadrić, A Aganovic, E Kadrić, B Delalić-Gurda, S Jackson Journal of Building Engineering 61, 105307, 2022 | 10 | 2022 |
Airflow distribution for minimizing human exposure to airborne contaminants in healthcare facilities A Aganovic NTNU: Trondheim, Norway, 2019 | 10 | 2019 |