Implantable ocular microapparatus to ameliorate glaucoma or an ocular overpressure causing disease FA Guarnieri US Patent 8,206,440, 2012 | 90 | 2012 |
Comparison of Placido-based, rasterstereography, and slit-scan corneal topography systems FA Guarnieri, JC Guarnieri Journal of refractive surgery 18 (2), 169-176, 2002 | 34 | 2002 |
Modeling and high performance simulation of electrophoretic techniques in microfluidic chips PA Kler, CLA Berli, FA Guarnieri Microfluidics and Nanofluidics 10 (1), 187-198, 2011 | 31 | 2011 |
High performance simulations of electrokinetic flow and transport in microfluidic chips PA Kler, EJ López, LD Dalcín, FA Guarnieri, MA Storti Computer Methods in Applied Mechanics and Engineering 198 (30-32), 2360-2367, 2009 | 30 | 2009 |
Corneal biomechanics and refractive surgery FA Guarnieri Springer New York, 2015 | 26 | 2015 |
Stress in human pelvis throughout the gait cycle: development, evaluation and sensitivity studies of a finite element model EP Ravera, MJ Crespo, FA Guarnieri, AA Braidot VI Latin American Congress on Biomedical Engineering CLAIB 2014, Paraná …, 2015 | 16 | 2015 |
Corneal biomechanics FA Guarnieri Corneal Biomechanics and Refractive Surgery, 7-31, 2014 | 14 | 2014 |
Assessment of thermal effects in a model of the human head implanted with a wireless active microvalve for the treatment of glaucoma creating a filtering bleb F Schaumburg, FA Guarnieri Physics in Medicine & Biology 62 (9), N191, 2017 | 13 | 2017 |
Design, construction and testing of a monolithic pH-sensitive hydrogel-valve for biochemical and medical application VC Ayala, M Michalzik, S Harling, H Menzel, FA Guarnieri, S Büttgenbach Journal of Physics: Conference Series 90 (1), 012025, 2007 | 13 | 2007 |
Intraocular pressure: Goldmann tonometry, computational model, and calibration equation AF Guzmán, AA Castilla, FA Guarnieri, FR Rodríguez Journal of glaucoma 22 (1), 10-14, 2013 | 11 | 2013 |
Modelo biomecánico del ojo para diseño asistido por computadora de la cirugía refractiva FA Guarnieri PhD Thesis, Universidad Nacional del Litoral, Santa Fe, Argentina, 1999 | 11 | 1999 |
Characterisation and simulation of an active microvalve for glaucoma F Sassetti, FA Guarnieri, L Garelli, MA Storti Computer methods in biomechanics and biomedical engineering 15 (12), 1273-1280, 2012 | 9 | 2012 |
Combined finite element and musculoskeletal models for analysis of pelvis throughout the gait cycle E Ravera, M Crespo, F Guarnieri, A Braidot PANACM, 2015 | 8 | 2015 |
Diamond-based thin film bulk acoustic wave resonator for biomedical applications M Zalazar, F Guarnieri Journal of Physics: Conference Series 477 (1), 012009, 2013 | 8 | 2013 |
Análisis y evaluación del comportamiento de sensores piezoeléctricos MA Zalazar, FA Guarnieri Mecánica Computacional 29 (67), 6665-6684, 2010 | 7 | 2010 |
Microbalanza de cristal de cuarzo: diseño y simulación MA Zalazar, FA Guarnieri Mecánica Computacional 28 (25), 2123-2136, 2009 | 7 | 2009 |
Computational investigation of the biomechanical response of the cornea to lamellar procedures. FA Guarnieri, PM Pinsky, J Shimmick INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE 42 (4), S603-S603, 2001 | 6 | 2001 |
Introduction: Corneal Biomechanics and Refractive Surgery FA Guarnieri Corneal Biomechanics and Refractive Surgery, 1-6, 2014 | 5 | 2014 |
Numerical simulation of electrokinetic flow in microfluidic chips FA Guarnieri, PA Kler, CLA Berli Asociación Argentina de Mecánica Computacional, 2006 | 5 | 2006 |
3d viscoelastic nonlinear incompressible finite element in large strain of the cornea. application in refractive surgery FA Guarnieri, A Cardona Articles in CD-ROM Fourth World Congress of Computational Mechanics 2, 1998 | 5 | 1998 |