Dehumidification of moist air with simultaneous removal of selected indoor pollutants by triethylene glycol solutions in a packed-bed absorber TW Chung, TK Ghosh, AL Hines, D Novosel Separation Science and Technology 30 (7-9), 1807-1832, 1995 | 74 | 1995 |
Performance optimization of rotary dehumidifiers W Zheng, WM Worek, D Novosel | 69 | 1995 |
The seasonal performance of a liquid-desiccant air conditioner A Lowenstein, D Novosel American Society of Heating, Refrigerating and Air-Conditioning Engineers …, 1995 | 37 | 1995 |
Control and optimization of rotational speeds for rotary dehumidifiers W Zheng, WM Worek, D Novosel TRANSACTIONS-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR CONDITIONING …, 1993 | 27 | 1993 |
Removal of selected pollutants from air during dehumidification by lithium chloride and triethylene glycol solutions. TW Chung, TK Ghosh, AL Hines, D Novosel ASHRAE, ATLANTA, GA(USA)., 1993 | 24 | 1993 |
Simulation of advanced gas-fired desiccant systems WM Worek, W Zheng, WA Belding, D Novosel, WD Holeman Ashrae Trans 97 (2), 609-14, 1991 | 23 | 1991 |
Effect of operating conditions on optimal performance of rotary dehumidifiers W Zheng, WM Worek, D Novosel | 19 | 1995 |
Performance analysis of open-cycle desiccant cooling systems RK Collier Jr, D Novosel, WM Worek ASHRAE transactions 96 (Pt 1), 1990 | 18 | 1990 |
Ventilation rates and health: report of an interdisciplinary review of the scientific literature J Sundell, H Levin, D Novosel National Center for Energy Management and Building Technologies, 2006 | 16 | 2006 |
Advances in desiccant technologies D Novosel Energy engineering 93 (1), 6, 1996 | 14 | 1996 |
Simulation of open-cycle desiccant cooling system performance RK Collier Jr, D Novosol, WM Worek ASHRAE Transactions 96 (1), 1262-1268, 1990 | 14 | 1990 |
Reduced energy use through reduced indoor contamination in residential buildings D Kosar, D Novosel | 12 | 2006 |
Development of an operation and maintenance rating system for commercial buildings R Prill, R Kunkle, D Novosel Washington State University Extension Energy Program, 2009 | 10 | 2009 |
Airborne microorganisms: their occurrence and removal KA Robertson, TK Ghosh, AL Hines, SK Loyalka, D Novosel, ... Indoor Air 90, 1990 | 8 | 1990 |
Comparative analysis of conventional and underfloor air distribution system performance using the air diffusion performance index method JE Woods, D Novosel Extended abstract of technical report, the National Center for Energy …, 2008 | 7 | 2008 |
Impact of environmental tobacco smoke on the water adsorption capacity of desiccant materials SY Lee, TK Ghosh, AL Hines, D Novosel Gas separation & purification 9 (4), 285-291, 1995 | 6 | 1995 |
Evaluation of a Liquid Desiccant-Enhanced Heat Pipe Air Preconditioner AA Pesaran, YO Parent, M Meckler, D Novosel TRANSACTIONS-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR CONDITIONING …, 1995 | 6 | 1995 |
Reduced energy use through reduced indoor contamination in residential settings W Chen, Z Gao, J Zhang, D Kosar, C Walker, D Novosel Alexandria, VA: National Center for Energy Management and Building Technologies, 2006 | 5 | 2006 |
Scientific Outreach Program Pilot JE Woods, R Sweetser, D Novosel Alexandria, VA: National Center for Energy Management and Building Technologies, 2009 | 4 | 2009 |
Development of Assessment Protocols for Security Measures-A Scoping Study W Bahnfleth, J Freihaut, J Bem, TA Reddy, S Snyder, D Novosel Subtask, 2008 | 4 | 2008 |