Segueix
Davor Novosel
Davor Novosel
National Energy Management Institute Committee
Correu electrònic verificat a nemiconline.org - Pàgina d'inici
Títol
Citada per
Citada per
Any
Dehumidification of moist air with simultaneous removal of selected indoor pollutants by triethylene glycol solutions in a packed-bed absorber
TW Chung, TK Ghosh, AL Hines, D Novosel
Separation Science and Technology 30 (7-9), 1807-1832, 1995
741995
Performance optimization of rotary dehumidifiers
W Zheng, WM Worek, D Novosel
691995
The seasonal performance of a liquid-desiccant air conditioner
A Lowenstein, D Novosel
American Society of Heating, Refrigerating and Air-Conditioning Engineers …, 1995
371995
Control and optimization of rotational speeds for rotary dehumidifiers
W Zheng, WM Worek, D Novosel
TRANSACTIONS-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR CONDITIONING …, 1993
271993
Removal of selected pollutants from air during dehumidification by lithium chloride and triethylene glycol solutions.
TW Chung, TK Ghosh, AL Hines, D Novosel
ASHRAE, ATLANTA, GA(USA)., 1993
241993
Simulation of advanced gas-fired desiccant systems
WM Worek, W Zheng, WA Belding, D Novosel, WD Holeman
Ashrae Trans 97 (2), 609-14, 1991
231991
Effect of operating conditions on optimal performance of rotary dehumidifiers
W Zheng, WM Worek, D Novosel
191995
Performance analysis of open-cycle desiccant cooling systems
RK Collier Jr, D Novosel, WM Worek
ASHRAE transactions 96 (Pt 1), 1990
181990
Ventilation rates and health: report of an interdisciplinary review of the scientific literature
J Sundell, H Levin, D Novosel
National Center for Energy Management and Building Technologies, 2006
162006
Advances in desiccant technologies
D Novosel
Energy engineering 93 (1), 6, 1996
141996
Simulation of open-cycle desiccant cooling system performance
RK Collier Jr, D Novosol, WM Worek
ASHRAE Transactions 96 (1), 1262-1268, 1990
141990
Reduced energy use through reduced indoor contamination in residential buildings
D Kosar, D Novosel
122006
Development of an operation and maintenance rating system for commercial buildings
R Prill, R Kunkle, D Novosel
Washington State University Extension Energy Program, 2009
102009
Airborne microorganisms: their occurrence and removal
KA Robertson, TK Ghosh, AL Hines, SK Loyalka, D Novosel, ...
Indoor Air 90, 1990
81990
Comparative analysis of conventional and underfloor air distribution system performance using the air diffusion performance index method
JE Woods, D Novosel
Extended abstract of technical report, the National Center for Energy …, 2008
72008
Impact of environmental tobacco smoke on the water adsorption capacity of desiccant materials
SY Lee, TK Ghosh, AL Hines, D Novosel
Gas separation & purification 9 (4), 285-291, 1995
61995
Evaluation of a Liquid Desiccant-Enhanced Heat Pipe Air Preconditioner
AA Pesaran, YO Parent, M Meckler, D Novosel
TRANSACTIONS-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR CONDITIONING …, 1995
61995
Reduced energy use through reduced indoor contamination in residential settings
W Chen, Z Gao, J Zhang, D Kosar, C Walker, D Novosel
Alexandria, VA: National Center for Energy Management and Building Technologies, 2006
52006
Scientific Outreach Program Pilot
JE Woods, R Sweetser, D Novosel
Alexandria, VA: National Center for Energy Management and Building Technologies, 2009
42009
Development of Assessment Protocols for Security Measures-A Scoping Study
W Bahnfleth, J Freihaut, J Bem, TA Reddy, S Snyder, D Novosel
Subtask, 2008
42008
En aquests moments el sistema no pot dur a terme l'operació. Torneu-ho a provar més tard.
Articles 1–20