T2prep three‐dimensional spiral imaging with efficient whole brain coverage for myelin water quantification at 1.5 tesla TD Nguyen, C Wisnieff, MA Cooper, D Kumar, A Raj, P Spincemaille, ... Magnetic resonance in medicine 67 (3), 614-621, 2012 | 91 | 2012 |
Heterogeneity of multiple sclerosis lesions in multislice myelin water imaging TD Faizy, C Thaler, D Kumar, J Sedlacik, G Broocks, M Grosser, ... PloS one 11 (3), e0151496, 2016 | 79 | 2016 |
A Bayesian Algorithm Using Spatial Priors for Multi-Exponential T2 Relaxometry from Multi-Echo Spin Echo MRI D Kumar, TD Nguyen, SA Gauthier, Raj, A. In: Proceeding of International Society of Magnetic Resonance in Medicine …, 2012 | 75 | 2012 |
The myelin water fraction serves as a marker for age-related myelin alterations in the cerebral white matter–a multiparametric MRI aging study TD Faizy, C Thaler, G Broocks, F Flottmann, H Leischner, H Kniep, ... Frontiers in neuroscience 14, 136, 2020 | 62 | 2020 |
Age-related measurements of the myelin water fraction derived from 3D multi-echo GRASE reflect myelin content of the cerebral white matter TD Faizy, D Kumar, G Broocks, C Thaler, F Flottmann, H Leischner, ... Scientific reports 8 (1), 14991, 2018 | 56 | 2018 |
The correlation of hippocampal T2-mapping with neuropsychology test in patients with Alzheimer’s disease Z Luo, X Zhuang, D Kumar, X Wu, C Yue, C Han, J Lv PloS one 8 (9), e76203, 2013 | 53 | 2013 |
Reproducibility of 2D GluCEST in healthy human volunteers at 7 T RPR Nanga, C DeBrosse, D Kumar, D Roalf, B McGeehan, K D'Aquilla, ... Magnetic resonance in medicine, 2018 | 42 | 2018 |
Using 3D spatial correlations to improve the noise robustness of multi component analysis of 3D multi echo quantitative T2 relaxometry data D Kumar, H Hariharan, TD Faizy, P Borchert, S Siemonsen, J Fiehler, ... NeuroImage, 583-601, 2018 | 38 | 2018 |
Noise robust spatially regularized myelin water fraction mapping with the intrinsic B1‐error correction based on the linearized version of the extended phase graph … D Kumar, S Siemonsen, C Heesen, J Fiehler, J Sedlacik Journal of Magnetic Resonance Imaging 43 (4), 800-817, 2016 | 38 | 2016 |
Accelerating GluCEST imaging using deep learning for B0 correction Y Li, D Xie, A Cember, RPR Nanga, H Yang, D Kumar, H Hariharan, L Bai, ... Magnetic resonance in medicine 84 (4), 1724-1733, 2020 | 37 | 2020 |
Recovery kinetics of creatine in mild plantar flexion exercise using 3D creatine CEST imaging at 7 Tesla D Kumar, RPR Nanga, D Thakuri, N Wilson, A Cember, ML Martin, D Zhu, ... Magnetic Resonance in Medicine, 2020 | 23 | 2020 |
Multimodality assessment of heart failure with preserved ejection fraction skeletal muscle reveals differences in the machinery of energy fuel metabolism P Zamani, EA Proto, N Wilson, H Fazelinia, H Ding, LA Spruce, ... ESC Heart Failure 8 (4), 2698-2712, 2021 | 22 | 2021 |
Fast automatic segmentation of thalamic nuclei from MP2RAGE acquisition at 7 Tesla R Datta, MK Bacchus, D Kumar, MA Elliott, A Rao, S Dolui, R Reddy, ... Magnetic Resonance in Medicine 85 (5), 2781-2790, 2021 | 20 | 2021 |
Improved method for post‐processing correction of B1 inhomogeneity in glutamate‐weighted CEST images of the human brain ATJ Cember, H Hariharan, D Kumar, RPR Nanga, R Reddy NMR in Biomedicine 34 (6), e4503, 2021 | 14 | 2021 |
Probing medium-range structural correlations by fluctuation microscopy MMJ Treacy, D Kumar, A Rougée, G Zhao, PR Buseck, I McNulty, L Fan, ... Journal of Physics: Condensed Matter 19 (45), 455201, 2007 | 12 | 2007 |
Quantitative imaging of the spine in adolescent idiopathic scoliosis: shifting the paradigm from diagnostic to comprehensive prognostic evaluation S Pasha, CR Rajapaske, R Reddy, B Diebo, P Knott, BC Jones, D Kumar, ... European Journal of Orthopaedic Surgery & Traumatology 31, 1273-1285, 2021 | 9 | 2021 |
Whole brain 3D spiral imaging for multi-component T2 relaxometry of multiple sclerosis in 10 minutes: a feasibility study at 3 Tesla TD Nguyen, C Wisnieff, MA Cooper, J Comunale, D Kumar, A Raj, ... Proceedings of ISMRM, Montreal, Canada 4078, 2011 | 6 | 2011 |
The CALIPR framework for highly accelerated myelin water imaging with improved precision and sensitivity AV Dvorak, D Kumar, J Zhang, G Gilbert, S Balaji, N Wiley, C Laule, ... Science Advances 9 (44), eadh9853, 2023 | 5 | 2023 |
Feasibility of transient nuclear Overhauser effect imaging in brain at 7 T D Kumar, B Benyard, ND Soni, A Swain, N Wilson, R Reddy Magnetic Resonance in Medicine 89 (4), 1357-1367, 2023 | 4 | 2023 |
Early-stage mapping of macromolecular content in APPNL-F mouse model of Alzheimer’s disease using nuclear Overhauser effect MRI A Swain, ND Soni, N Wilson, H Juul, B Benyard, M Haris, D Kumar, ... Frontiers in Aging Neuroscience 15, 1266859, 2023 | 3 | 2023 |