Følg
Murat GÜNAYDIN
Titel
Citeret af
Citeret af
År
Construction stage analysis of humber suspension bridge
S Adanur, M Günaydin, AC Altunişik, B Sevim
Applied Mathematical Modelling 36 (11), 5492-5505, 2012
622012
Seismic damage assessment of masonry buildings in Elazığ and Malatya following the 2020 Elazığ-Sivrice earthquake, Turkey
M Günaydin, B Atmaca, S Demir, AC Altunişik, M Hüsem, S Adanur, ...
Bulletin of Earthquake Engineering 19, 2421-2456, 2021
512021
Dynamic analyses of experimentally-updated FE model of historical masonry clock towers using site-specific seismic characteristics and scaling parameters according to the 2018 …
AF Genc, M Ergün, M Günaydin, AC Altunişik, Ş Ateş, FY Okur, ...
Engineering Failure Analysis 105, 402-426, 2019
472019
Automated model updating of historical masonry structures based on ambient vibration measurements
AC Altunişik, FY Okur, AF Genç, M Günaydin, S Adanur
Journal of Performance of Constructed Facilities 32 (1), 04017126, 2018
392018
Modal parameter identification of RC frame under undamaged, damaged, repaired and strengthened conditions
AC Altunişik, OŞ Karahasan, AF Genç, FY Okur, M Günaydin, E Kalkan, ...
Measurement 124, 260-276, 2018
372018
Non-destructive testing of an ancient masonry bastion
AC Altunişik, S Adanur, AF Genç, M Günaydin, FY Okur
Journal of Cultural Heritage 22, 1049-1054, 2016
362016
Lessons learned from the past earthquakes on building performance in Turkey
B Atmaca, S Demir, M Günaydın, AC Altunışık, M Hüsem, Ş Ateş, ...
J. Struct. Eng. Appl. Mech 3 (2), 61-84, 2020
332020
CFRP composite retrofitting effect on the dynamic characteristics of arch dams
AC Altunişik, M Günaydin, B Sevim, A Bayraktar, S Adanur
Soil dynamics and earthquake engineering 74, 1-9, 2015
292015
Performance Evaluation of Reinforced Concrete Buildings During the Sivrice-Elazığ Earthquake (, January 24, 2020) in Accordance with Turkish …
S Demir, M Günaydin, B Atmaca, AC Altunişik, M Hüsem, S Adanur, ...
Journal of Earthquake and Tsunami 15 (04), 2150018, 2021
282021
Field investigation on the performance of mosques and minarets during the Elazig-Sivrice Earthquake
B Atmaca, S Demir, M Günaydin, AC Altunişik, M Hüsem, Ş Ateş, ...
Journal of performance of constructed facilities 34 (6), 04020120, 2020
272020
An investigation of the seismic behaviour of an ancient masonry bastion using non-destructive and numerical methods
AC Altunisik, S Adanur, AF Genc, M Gunaydin, FY Okur
Experimental Mechanics 57, 245-259, 2017
272017
Dynamic response of a historical armory building using the finite element model validated by the ambient vibration test
AC Altunişik, AF Genç, M Günaydin, FY Okur, OŞ Karahasan
Journal of Vibration and Control 24 (22), 5472-5484, 2018
252018
Determination of structural behavior of Bosporus suspension bridge considering construction stages and different soil conditions
M Gunaydin, S Adanur, AC Altunisik, B Sevim, E Turker
Steel and Composite Structures 17 (4), 405-429, 2014
242014
Assessment of structural damage following the October 30, 2020 Aegean Sea Earthquake and Tsunami
AC Altunişik, B Atmaca, ME Kartal, M Günaydin, S Demir, A Uluşan
Journal of Earthquake and Tsunami 15 (06), 2150029, 2021
212021
Evaluation of earthquake-related damages on masonry structures due to the 6 February 2023 Kahramanmaraş-Türkiye earthquakes: A case study for Hatay Governorship Building
V Kahya, AF Genç, F Sunca, B Roudane, AC Altunişik, S Yilmaz, ...
Engineering Failure Analysis 156, 107855, 2024
202024
Diagnosis and monitoring of historical timber velipaşa han building prior to restoration
M Günaydin, C Demirkir, AC Altunişik, ED Gezer, AF Genc, FY Okur
International Journal of Architectural Heritage 17 (2), 285-309, 2023
202023
Post-earthquake damage assessments of unreinforced masonry (URM) buildings by shake table test and numerical visualization
A Kaya, S Adanur, RA Bello, AF Genç, FY Okur, F Sunca, M Günaydin, ...
Engineering Failure Analysis 143, 106858, 2023
202023
Retrofitting effect on the dynamic properties of model-arch dam with and without reservoir water using ambient-vibration test methods
AC Altunişik, M Günaydin, B Sevim, A Bayraktar, S Adanur
Journal of Structural Engineering 142 (10), 04016069, 2016
202016
Static and dynamic responses of Halgavor Footbridge using steel and FRP materials
M Gunaydin, S Adanur, AC Altunisik, B Sevim
Steel Compos. Struct 18 (1), 51-69, 2015
202015
Dynamic responses of industrial reinforced concrete chimneys strengthened with fiber‐reinforced polymers
Z Karaca, E Türkeli, M Günaydın, S Adanur
The Structural Design of Tall and Special Buildings 24 (3), 228-241, 2015
182015