Følg
Rajesh Ghosh
Rajesh Ghosh
Associate Professor, School of Mechanical and Materials Engineering, IIT Mandi
Verificeret mail på iitmandi.ac.in - Startside
Titel
Citeret af
Citeret af
År
Finite element analysis of a hemi-pelvis: the effect of inclusion of cartilage layer on acetabular stresses and strain
R Ghosh, B Pal, D Ghosh, S Gupta
Computer methods in biomechanics and biomedical engineering 18 (7), 697-710, 2015
852015
Experimental validation of finite element models of intact and implanted composite hemipelvises using digital image correlation
R Ghosh, S Gupta, A Dickinson, M Browne
Journal of Biomechanical Engineering 134 (8), 081003, 2012
832012
Bone remodelling around cementless composite acetabular components: the effects of implant geometry and implant–bone interfacial conditions
R Ghosh, S Gupta
Journal of the Mechanical Behavior of Biomedical materials 32, 257-269, 2014
662014
Bone remodelling around uncemented metallic and ceramic acetabular components
R Ghosh, K Mukherjee, S Gupta
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2013
502013
A numerical study on stress distribution across the ankle joint: Effects of material distribution of bone, muscle force and ligaments
S Mondal, R Ghosh
Journal of orthopaedics 14 (3), 329-335, 2017
432017
Effects of implant orientation and implant material on tibia bone strain, implant–bone micromotion, contact pressure, and wear depth due to total ankle replacement
S Mondal, R Ghosh
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2019
402019
Experimental validation of numerically predicted strain and micromotion in intact and implanted composite hemi-pelvises
R Ghosh, S Gupta, A Dickinson, M Browne
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2013
352013
The effects of implant orientations and implant–bone interfacial conditions on potential causes of failure of tibial component due to total ankle replacement
S Mondal, R Ghosh
Journal of Medical and Biological Engineering 39, 541-551, 2019
262019
Bone remodelling around the tibia due to total ankle replacement: effects of implant material and implant–bone interfacial conditions
S Mondal, R Ghosh
Computer Methods in Biomechanics and Biomedical Engineering 22 (16), 1247-1257, 2019
252019
Biomechanical analysis of three popular tibial designs for TAR with different implant-bone interfacial conditions and bone qualities: A finite element study
Jyoti, S Mondal, R Ghosh
Medical Engineering & Physics 104, 103812, 2022
232022
A review on experimental and numerical investigations of cortical bone fracture
A Kumar, R Ghosh
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2022
232022
Experimental and numerical comparisons between finite element method, element-free Galerkin method, and extended finite element method predicted stress intensity factor and …
A Kumar, P Shitole, R Ghosh, R Kumar, A Gupta
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2019
222019
Experimental and finite element investigation of total ankle replacement: A review of literature and recommendations
S Mondal, R Ghosh
Journal of Orthopaedics 18, 41-49, 2020
192020
Fracture toughness of acrylic PMMA bone cement: a mini-review
A Kumar, R Ghosh
Indian Journal of Orthopaedics 55 (5), 1208-1214, 2021
172021
Assessment of failure of cemented polyethylene acetabular component due to bone remodeling: A finite element study
R Ghosh
Journal of Orthopaedics 13 (3), 140-147, 2016
172016
Effects of interfacial crack and implant material on mixed‐mode stress intensity factor and prediction of interface failure of cemented acetabular cup
A Kumar, R Ghosh, R Kumar
Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2019
152019
Towards the optimal design of an uncemented acetabular component using genetic algorithms
R Ghosh, DK Pratihar, S Gupta
Engineering Optimization 47 (12), 1587 - 1601, 2015
142015
Stability analysis of a flexible spinning and precessing rotor with non-symmetric shaft
R Ghosh, A Saha, A Nandi, S Neogy
Journal of Vibration and Control 16 (1), 107-125, 2010
122010
Influence of cancellous bone material and dead zone on stress-strain, bone stimulus and bone remodelling around the tibia for total ankle replacement
S Mondal, R Ghosh
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2021
112021
Low viscosity versus high viscosity PMMA bone cement for total joint arthroplasty: Influence of glass transition temperature, residual monomer content, transmittance of …
SP Chaurasiya, R Ghosh
Forces in Mechanics 10, 100176, 2023
102023
Systemet kan ikke foretage handlingen nu. Prøv igen senere.
Artikler 1–20