Bicycle helmets are highly effective at preventing head injury during head impact: Head-form accelerations and injury criteria for helmeted and unhelmeted impacts PA Cripton, DM Dressler, CA Stuart, CR Dennison, D Richards Accident Analysis & Prevention 70, 1-7, 2014 | 205 | 2014 |
A qualitative review of sports concussion education: prime time for evidence-based knowledge translation M Mrazik, CR Dennison, BL Brooks, KO Yeates, S Babul, D Naidu British journal of sports medicine 49 (24), 1548-1553, 2015 | 131 | 2015 |
Ex vivo measurement of lumbar intervertebral disc pressure using fibre-Bragg gratings CR Dennison, PM Wild, PWG Byrnes, A Saari, E Itshayek, DC Wilson, ... Journal of biomechanics 41 (1), 221-225, 2008 | 68 | 2008 |
A minimally invasive in-fiber Bragg grating sensor for intervertebral disc pressure measurements CR Dennison, PM Wild, DR Wilson, PA Cripton Measurement Science and Technology 19 (8), 085201, 2008 | 62 | 2008 |
Predicting Cumulative and Maximum Brain Strain Measures From HybridIII Head Kinematics: A Combined Laboratory Study and Post-Hoc Regression Analysis BM Knowles, CR Dennison Annals of biomedical engineering 45, 2146-2158, 2017 | 54 | 2017 |
An in-fiber Bragg grating sensor for contact force and stress measurements in articular joints CR Dennison, PM Wild, DR Wilson, MK Gilbart Measurement Science and Technology 21 (11), 115803, 2010 | 54 | 2010 |
Enhanced sensitivity of an in-fibre Bragg grating pressure sensor achieved through fibre diameter reduction CR Dennison, PM Wild Measurement Science and Technology 19 (12), 125301, 2008 | 50 | 2008 |
Validation of a Novel Minimally Invasive Intervertebral Disc Pressure Sensor Utilizing In-Fiber Bragg Gratings in a Porcine Model: An: Ex Vivo: Study CR Dennison, PM Wild, MF Dvorak, DR Wilson, PA Cripton Spine 33 (17), E589-E594, 2008 | 43 | 2008 |
Mechanisms of cervical spine injury in rugby union: is it premature to abandon hyperflexion as the main mechanism underpinning injury? CR Dennison, EM Macri, PA Cripton British journal of sports medicine 46 (8), 545-549, 2012 | 42 | 2012 |
Compressive follower load influences cervical spine kinematics and kinetics during simulated head-first impact in an in vitro model A Saari, CR Dennison, Q Zhu, TS Nelson, P Morley, TR Oxland, ... Journal of biomechanical engineering 135 (11), 111003, 2013 | 30 | 2013 |
Mechanically stable intraspinal microstimulation implants for human translation A Toossi, DG Everaert, A Azar, CR Dennison, VK Mushahwar Annals of biomedical engineering 45, 681-694, 2017 | 28 | 2017 |
Effects of external helmet accessories on biomechanical measures of head injury risk: An ATD study using the HYBRIDIII headform RC Butz, BM Knowles, JA Newman, CR Dennison Journal of biomechanics 48 (14), 3816-3824, 2015 | 26 | 2015 |
Head games: a systematic review and meta-analysis examining concussion and head impact incidence rates, modifiable risk factors, and prevention strategies in youth tackle football MP Pankow, RA Syrydiuk, AT Kolstad, AK Hayden, CR Dennison, ... Sports medicine 52 (6), 1259-1272, 2022 | 22 | 2022 |
A test bed to examine helmet fit and retention and biomechanical measures of head and neck injury in simulated impact YY Henry, BM Knowles, CR Dennison Journal of Visualized Experiments: Jove, 56288, 2017 | 22 | 2017 |
A distributed pressure measurement system comprising multiplexed in-fibre Bragg gratings within a flexible superstructure DA Singlehurst, CR Dennison, PM Wild Journal of lightwave technology 30 (1), 123-129, 2011 | 22 | 2011 |
Stress Measurements on the Articular Cartilage Surface Using Fiber Optic Technology and In-Vivo Gait Kinematics P Vakiel, M Shekarforoush, CR Dennison, M Scott, CB Frank, DA Hart, ... Annals of Biomedical Engineering 48, 2836-2845, 2020 | 20 | 2020 |
High rate compressive behaviour of a dilatant polymeric foam KB Bhagavathula, A Azar, S Ouellet, S Satapathy, CR Dennison, ... Journal of Dynamic Behavior of Materials 4, 573-585, 2018 | 20 | 2018 |
Superstructured fiber-optic contact force sensor<? A3B2 show [pmg: line-break justify=" yes"/]?> with minimal cosensitivity to temperature<? A3B2 show [pmg: line-break justify … CR Dennison, PM Wild Applied optics 51 (9), 1188-1197, 2012 | 20 | 2012 |
Protective headgear attenuates forces on the inner table and pressure in the brain parenchyma during blast and impact: an experimental study using a simulant-based surrogate … A Azar, KB Bhagavathula, J Hogan, S Ouellet, S Satapathy, CR Dennison Journal of biomechanical engineering 142 (4), 041009, 2020 | 18 | 2020 |
Sensitivity of Bragg gratings in birefringent optical fiber to transverse compression between conforming materials CR Dennison, PM Wild Applied Optics 49 (12), 2250-2261, 2010 | 17 | 2010 |