Experimental study on dehumidifier and regenerator of liquid desiccant cooling air conditioning system Y Yin, X Zhang, Z Chen Building and environment 42 (7), 2505-2511, 2007 | 225 | 2007 |
Experimental study on a new internally cooled/heated dehumidifier/regenerator of liquid desiccant systems Y Yin, X Zhang, G Wang, L Luo International Journal of Refrigeration 31 (5), 857-866, 2008 | 198 | 2008 |
Recent advancements in liquid desiccant dehumidification technology Y Yin, J Qian, X Zhang Renewable and Sustainable Energy Reviews 31, 38-52, 2014 | 155 | 2014 |
Model validation and case study on internally cooled/heated dehumidifier/regenerator of liquid desiccant systems Y Yin, X Zhang, D Peng, X Li International journal of thermal sciences 48 (8), 1664-1671, 2009 | 142 | 2009 |
Experimental study on displacement and mixing ventilation systems for a patient ward Y Yin, W Xu, JK Gupta, A Guity, P Marmion, A Manning, B Gulick, X Zhang, ... HVAC&R Research 15 (6), 1175-1191, 2009 | 121 | 2009 |
Comparative study on internally heated and adiabatic regenerators in liquid desiccant air conditioning system Y Yin, X Zhang Building and environment 45 (8), 1799-1807, 2010 | 120 | 2010 |
Determination of the PCM melting temperature range using DSC X Jin, X Xu, X Zhang, Y Yin Thermochimica acta 595, 17-21, 2014 | 109 | 2014 |
A new method for determining coupled heat and mass transfer coefficients between air and liquid desiccant Y Yin, X Zhang International journal of heat and mass transfer 51 (13-14), 3287-3297, 2008 | 109 | 2008 |
Airborne transmission of COVID‐19 virus in enclosed spaces: an overview of research methods X Zhao, S Liu, Y Yin, T Zhang, Q Chen Indoor air 32 (6), e13056, 2022 | 107 | 2022 |
A novel low-grade heat-driven absorption refrigeration system with LiCl–H2O and LiBr–H2O working pairs X She, Y Yin, M Xu, X Zhang International Journal of Refrigeration 58, 219-234, 2015 | 98 | 2015 |
Experimental and theoretical analysis of liquid desiccant dehumidification process based on an advanced hybrid air-conditioning system Y Chen, X Zhang, Y Yin Applied Thermal Engineering 98, 387-399, 2016 | 83 | 2016 |
Performance analysis of a hybrid air-conditioning system dehumidified by liquid desiccant with low temperature and low concentration Y Chen, Y Yin, X Zhang Energy and Buildings 77, 91-102, 2014 | 78 | 2014 |
Thermodynamic analysis of a novel energy-efficient refrigeration system subcooled by liquid desiccant dehumidification and evaporation X She, Y Yin, X Zhang Energy conversion and management 78, 286-296, 2014 | 75 | 2014 |
Bubble formation on solid surface with a cavity based on molecular dynamics simulation X She, TA Shedd, B Lindeman, Y Yin, X Zhang International Journal of Heat and Mass Transfer 95, 278-287, 2016 | 68 | 2016 |
A proposed subcooling method for vapor compression refrigeration cycle based on expansion power recovery X She, Y Yin, X Zhang International journal of refrigeration 43, 50-61, 2014 | 66 | 2014 |
Distributions of respiratory contaminants from a patient with different postures and exhaling modes in a single-bed inpatient room Y Yin, JK Gupta, X Zhang, J Liu, Q Chen Building and environment 46 (1), 75-81, 2011 | 64 | 2011 |
Performance analysis of a novel liquid desiccant evaporative cooling fresh air conditioning system with solution recirculation F Zhang, Y Yin, X Zhang Building and Environment 117, 218-229, 2017 | 60 | 2017 |
A proposed compressed air drying method using pressurized liquid desiccant and experimental verification Y Yin, B Zheng, C Yang, X Zhang Applied Energy 141, 80-89, 2015 | 49 | 2015 |
Review of internally cooled liquid desiccant air dehumidification: Materials, components, systems, and performances B Guan, T Zhang, J Liu, X Liu, Y Yin Building and Environment 211, 108747, 2022 | 43 | 2022 |
Feasibility and performance analysis of a desiccant solution regenerator using hot air Y Yin, S Li, X Zhang, D Peng Energy and buildings 43 (5), 1097-1104, 2011 | 41 | 2011 |