Folgen
NADI Mustapha
NADI Mustapha
Université de Lorraine-CNRS UMR 7198
Bestätigte E-Mail-Adresse bei univ-lorraine.fr - Startseite
Titel
Zitiert von
Zitiert von
Jahr
Geometric parameters optimization of planar interdigitated electrodes for bioimpedance spectroscopy
MN Mouhamad Ibrahim, Julien Claudel, Djilali
J Electr Bioimp 4, 13-22, 2013
1572013
Dielectric properties of blood: an investigation of haematocrit dependence
F Jaspard, M Nadi, A Rouane
Physiological measurement 24 (1), 137, 2003
1432003
Dielectric properties of blood: an investigation of temperature dependence
F Jaspard, M Nadi
Physiological measurement 23 (3), 547, 2002
1252002
A four-electrode low frequency impedance spectroscopy measurement system using the AD5933 measurement chip
C Margo, J Katrib, M Nadi, A Rouane
Physiological measurement 34 (4), 391, 2013
1012013
Non-invasive glycaemia blood measurements by electromagnetic sensor: study in static and dynamic blood circulation
M Gourzi, A Rouane, R Guelaz, MS Alavi, MB McHugh, M Nadi, P Roth
Journal of medical engineering & technology 29 (1), 22-26, 2005
792005
Dielectric properties of gelatine phantoms used for simulations of biological tissues between 10 and 50 MHz
C Marchal, M Nadi, AJ Tosser, C Roussey, ML Gaulard
International journal of hyperthermia 5 (6), 725-732, 1989
691989
AN COST-EFFECTIVE TEST BENCH FOR ACTIVE CARDIAC IMPLANTS, REPRODUCING HUMAN EXPOSURE TO ELECTRIC FIELDS 50 HZ
C Gercek, D Kourtiche, M Nadi, I Magne, P Schmitt, P Roth
International Journal on Smart Sensing and Intelligent Systems 10 (1), 1-17, 2017
492017
Design and Realization of a Planar Interdigital Microsensor for Biological Medium Characterization
TT Ngo, A Bourjilat, J Claudel, D Kourtiche, M Nadi
Next Generation Sensors and Systems 16, 23, 2015
332015
Study of a new electromagnetic sensor for glycaemia measurement: in vitro results on blood pig
M Gourzi, A Rouane, R Guelaz, M Nadi, F Jaspard
Journal of medical engineering & technology 27 (6), 276-281, 2003
332003
Practical interstitial method of heating operating at 27.12 MHz
C Marchal, M Nadi, S Hoffstetter, P Bey, M Pernot, G Prieur
International journal of hyperthermia 5 (4), 451-466, 1989
311989
Needle-type GMR Sensor to Estimate the Magnetic Properties of Diluted Ferrofluid for Biomedicine Application
Shirzadfar H, Nadi M, Kourtiche D, Yamada S, Hauet H
IRBM 36 (2), 2015
292015
Harmonic propagation of finite amplitude sound beams: comparative method in pulse echo measurement of nonlinear B/A parameter
D Kourtiche, L Alliès, A Chitnalah, M Nadi
Measurement Science and technology 12 (11), 1990, 2001
262001
CHARACTERIZATION OF A NEEDLE-TYPE GIANT MAGNETORESISTANCE SENSOR FOR DETECTION OF ESCHERICHIA COLI’S MAGNETIC MARKER
H Shirzadfar, M Nadi, M Kourtiche, S Yamada, S Payman
International Journal on Smart Sensing and Intelligent Systems 8 (1), 220 – 234, 2015
212015
Detecting and estimating magnetic fluid properties by a needle-type GMR sensor
H Shirzadfar, D Kourtiche, R Haraszczuk, M Nadi, S Yamada
Proceedings of the International Conference Nanomaterials: Applications and …, 2012
212012
Physical and Electrical Modeling of Interdigitated Electrode Arrays for Bioimpedance Spectroscopy
M Ibrahim, J Claudel, D Kourtiche, B Assouar, M Nadi
New Developments and Applications in Sensing Technology, 169-189, 2011
212011
CHARACTERIZATION OF A NEEDLE-TYPE GIANT MAGNETORESISTANCE SENSOR FOR DETECTION OF ESCHERICHIA COLI’S MAGNETIC MARKER
SYPS Hamidreza Shirzadfar, Mustapha Nadi, Djilali Kourtiche
International Journal on Smart Sensing and Intelligent Systems 8 (1), 220 – 234, 201
21*201
A planar interdigital sensor for bio-impedance measurement: theoretical analysis, optimization and simulation
N Thanh-Tuan, S Hamidreza, K Djilali, N Mustapha
Sumy State University, 2014
202014
In vitro assessment of the immunity of implantable cardioverter-defibrillators to magnetic fields of 50/60 Hz
J Katrib, M Nadi, D Kourtiche, M Souques, P Roth
Physiological measurement 34 (10), 1281-92, 2013
182013
An original method for non-invasive glucose measurement: preliminary results
SM Alavi, M Gourzi, A Rouane, M Nadi
2001 Conference Proceedings of the 23rd Annual International Conference of …, 2001
182001
Interdigitated Sensor Optimization for Blood Sample Analysis
J Claudel, TT Ngo, D Kourtiche, M Nadi
Biosensors 2020 10 (12), 208, 2020
162020
Das System kann den Vorgang jetzt nicht ausführen. Versuchen Sie es später erneut.
Artikel 1–20