Παρακολούθηση
Lisa PRUITT
Lisa PRUITT
Η διεύθυνση ηλεκτρονικού ταχυδρομείου έχει επαληθευτεί στον τομέα berkeley.edu
Τίτλος
Παρατίθεται από
Παρατίθεται από
Έτος
Nanoindentation of biological materials
DM Ebenstein, LA Pruitt
Nano today 1 (3), 26-33, 2006
6282006
Deformation, yielding, fracture and fatigue behavior of conventional and highly cross-linked ultra high molecular weight polyethylene
LA Pruitt
Biomaterials 26 (8), 905-915, 2005
3252005
Nanoindentation of polydimethylsiloxane elastomers: Effect of crosslinking, work of adhesion, and fluid environment on elastic modulus
F Carrillo, S Gupta, M Balooch, SJ Marshall, GW Marshall, L Pruitt, ...
Journal of materials research 20 (10), 2820-2830, 2005
2812005
The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic‐grade polyethylene
DA Baker, A Bellare, L Pruitt
Journal of Biomedical Materials Research Part A: An Official Journal of The …, 2003
2522003
Plasticity-induced damage layer is a precursor to wear in radiation-cross-linked UHMWPE acetabular components for total hip replacement
AA Edidin, L Pruitt, CW Jewett, DJ Crane, D Roberts, SM Kurtz
The Journal of arthroplasty 14 (5), 616-627, 1999
2351999
Nanoindentation of soft hydrated materials for application to vascular tissues
DM Ebenstein, LA Pruitt
Journal of Biomedical Materials Research Part A: An Official Journal of The …, 2004
2272004
Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene
DA Baker, RS Hastings, L Pruitt
Journal of Biomedical Materials Research: An Official Journal of The Society …, 1999
1991999
The yielding, plastic flow, and fracture behavior of ultra-high molecular weight polyethylene used in total joint replacements
SM Kurtz, L Pruitt, CW Jewett, RP Crawford, DJ Crane, AA Edidin
Biomaterials 19 (21), 1989-2003, 1998
1951998
Nanomechanical properties of polymers determined from nanoindentation experiments
C Klapperich, K Komvopoulos, L Pruitt
J. Trib. 123 (3), 624-631, 2001
1872001
Clinical fracture of cross-linked UHMWPE acetabular liners
J Furmanski, M Anderson, S Bal, AS Greenwald, D Halley, B Penenberg, ...
Biomaterials 30 (29), 5572-5582, 2009
1852009
Corrosion-induced fracture of a double-modular hip prosthesis: a case report
SA Atwood, EW Patten, KJ Bozic, LA Pruitt, MD Ries
JBJS 92 (6), 1522-1525, 2010
1842010
Determination of strain energy function for arterial elastin: experiments using histology and mechanical tests
N Gundiah, MB Ratcliffe, LA Pruitt
Journal of biomechanics 40 (3), 586-594, 2007
1822007
Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners
L Bradford, DA Baker, J Graham, A Chawan, MD Ries, LA Pruitt
JBJS 86 (6), 1271-1282, 2004
1822004
Nanomechanical properties of calcification, fibrous tissue, and hematoma from atherosclerotic plaques
DM Ebenstein, D Coughlin, J Chapman, C Li, LA Pruitt
Journal of Biomedical Materials Research Part A: An Official Journal of The …, 2009
1782009
Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene.
MD Ries, L Pruitt
Clinical Orthopaedics and Related Research (1976-2007) 440, 149-156, 2005
1752005
Tradeoffs amongst fatigue, wear, and oxidation resistance of cross-linked ultra-high molecular weight polyethylene
SA Atwood, DW Van Citters, EW Patten, J Furmanski, MD Ries, LA Pruitt
Journal of the mechanical behavior of biomedical materials 4 (7), 1033-1045, 2011
1662011
Mechanics of biomaterials: fundamental principles for implant design
LA Pruitt, AM Chakravartula
Cambridge University Press, 2011
1582011
The effects of gamma radiation sterilization and ageing on the structure and morphology of medical grade ultra high molecular weight polyethylene
M Goldman, R Gronsky, R Ranganathan, L Pruitt
Polymer 37 (14), 2909-2913, 1996
1581996
Comparison of the effects of gamma radiation and low temperature hydrogen peroxide gas plasma sterilization on the molecular structure, fatigue resistance, and wear behavior of …
M Goldman, L Pruitt
Journal of biomedical materials research 40 (3), 378-384, 1998
1511998
Fatigue crack propagation resistance of highly crosslinked polyethylene
L Bradford, D Baker, MD Ries, LA Pruitt
Clinical Orthopaedics and Related Research® 429, 68-72, 2004
1432004
Δεν είναι δυνατή η εκτέλεση της ενέργειας από το σύστημα αυτή τη στιγμή. Προσπαθήστε ξανά αργότερα.
Άρθρα 1–20