Fault location on power networks MM Saha, JJ Izykowski, E Rosolowski Springer Science & Business Media, 2009 | 1021 | 2009 |
Accurate noniterative fault-location algorithm utilizing two-end unsynchronized measurements J Izykowski, E Rosolowski, P Balcerek, M Fulczyk, MM Saha IEEE transactions on power delivery 26 (2), 547-555, 2009 | 197 | 2009 |
A new accurate fault locating algorithm for series compensated lines MM Saha, J Izykowski, E Rosolowski, B Kasztenny IEEE transactions on power delivery 14 (3), 789-797, 1999 | 196 | 1999 |
Accurate location of faults on power transmission lines with use of two-end unsynchronized measurements J Izykowski, R Molag, E Rosolowski, MM Saha IEEE Transactions on Power Delivery 21 (2), 627-633, 2006 | 176 | 2006 |
First zone algorithm for protection of series compensated lines MM Saha, B Kasztenny, E Rosolowski, J Izykowski IEEE Transactions on Power Delivery 16 (2), 200-207, 2001 | 134 | 2001 |
Arc effect on single-phase reclosing time of a UHV power transmission line IM Dudurych, TJ Gallagher, E Rosolowski IEEE Transactions on Power Delivery 19 (2), 854-860, 2004 | 132 | 2004 |
A fault-location method for application with current differential relays of three-terminal lines J Izykowski, E Rosolowski, MM Saha, M Fulczyk, P Balcerek IEEE Transactions on power delivery 22 (4), 2099-2107, 2007 | 125 | 2007 |
Dynamic compensation of capacitive voltage transformers J Izykowski, B Kasztenny, E Rosolowski, MM Saha, B Hillstrom IEEE Transactions on Power Delivery 13 (1), 116-122, 1998 | 104 | 1998 |
A self-organizing fuzzy logic based protective relay-an application to power transformer protection B Kasztenny, E Rosolowski, MM Saha, B Hillstrom IEEE Transactions on Power Delivery 12 (3), 1119-1127, 1997 | 101 | 1997 |
Tutorial on operating characteristics of microprocessor-based multiterminal line current differential relays B Kasztenny, G Benmouyal, HJ Altuve, N Fischer Present Problems of Power System Control, 2013 | 88 | 2013 |
Fault location on double-circuit series-compensated lines using two-end unsynchronized measurements J Izykowski, E Rosolowski, P Balcerek, M Fulczyk, MM Saha IEEE transactions on power delivery 26 (4), 2072-2080, 2011 | 80 | 2011 |
Fault location on power transmission lines J Iżykowski Oficyna Wydawnicza Politechniki Wrocławskiej, 2008 | 79 | 2008 |
Fuzzy logic controller for on-load transformer tap changer B Kasztenny, E Rosolowski, J Izykowski, MM Saha, B Hillstrom IEEE Transactions on Power Delivery 13 (1), 164-170, 1998 | 79 | 1998 |
Adaptive measuring algorithm suppressing a decaying DC component for digital protective relays E Rosołowski, J Iżykowski, B Kasztenny Electric Power Systems Research 60 (2), 99-105, 2001 | 66 | 2001 |
Post-fault analysis of operation of distance protective relays of power transmission lines J Izykowski, E Rosolowski, M Saha 2005 IEEE Russia Power Tech, 1-7, 2005 | 52 | 2005 |
Analysis of SDFT based phase detection system for grid synchronization of distributed generation systems BC Babu, K Sridharan, E Rosolowski, Z Leonowicz Engineering Science and Technology, an International Journal 17 (4), 270-278, 2014 | 46 | 2014 |
Cyfrowe przetwarzanie sygnałów w automatyce elektroenergetycznej E Rosołowski Akademicka Oficyna Wydawnicza EXIT, 2002 | 40 | 2002 |
Modelling of induction motor for simulation of internal faults M Wieczorek, E Rosołowski 2010 Modern Electric Power Systems, 1-6, 2010 | 39 | 2010 |
Fault location in uncompensated and series-compensated parallel lines MM Saha, K Wikstrom, J Izykowski, E Rosolowski 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings …, 2000 | 37 | 2000 |
Two new measuring algorithms for generator and transformer relaying B Kasztenny, E Rosolowski IEEE Transactions on Power Delivery 13 (4), 1053-1059, 1998 | 29 | 1998 |