Direct measurement of human movement by accelerometry A Godfrey, R Conway, D Meagher, G ÓLaighin Medical engineering & physics 30 (10), 1364-1386, 2008 | 871 | 2008 |
Improved RNS FIR filter architectures R Conway, J Nelson IEEE Transactions on Circuits and Systems II: Express Briefs 51 (1), 26-28, 2004 | 196 | 2004 |
Muscle activity in sprinting: a review RM Howard, R Conway, AJ Harrison Sports Biomechanics 17 (1), 1-17, 2018 | 134 | 2018 |
A review of postural orthostatic tachycardia syndrome S Carew, M O Connor, J Cooke, R Conway, C Sheehy, A Costelloe, ... EP-Europace 11 (1), 18-25, 2008 | 119 | 2008 |
A flexible low power DSP with a programmable truncated multiplier M de la Guia Solaz, W Han, R Conway IEEE Transactions on Circuits and Systems I: Regular Papers 59 (11), 2555-2568, 2012 | 64 | 2012 |
Fast converter for 3 moduli RNS using new property of CRT R Conway, J Nelson IEEE Transactions on Computers 48 (8), 852-860, 1999 | 60 | 1999 |
A programmable and portable NMES device for drop foot correction and blood flow assist applications PP Breen, GJ Corley, DT O’Keeffe, R Conway, G ÓLaighin Medical engineering & physics 31 (3), 400-408, 2009 | 47 | 2009 |
Motion analysis in delirium: A discrete approach in determining physical activity for the purpose of delirium motoric subtyping A Godfrey, R Conway, M Leonard, D Meagher, GM Ólaighin Medical engineering & physics 32 (2), 101-110, 2010 | 41 | 2010 |
A system for the delivery of programmable, adaptive stimulation intensity envelopes for drop foot correction applications PP Breen, DT O’Keeffe, R Conway, GM Lyons Medical engineering & physics 28 (2), 177-186, 2006 | 35 | 2006 |
A survey of sensor devices: use in sports biomechanics RM Howard, R Conway, AJ Harrison Sports biomechanics 15 (4), 450-461, 2016 | 27 | 2016 |
Muscle activation sequencing of leg muscles during linear glide shot putting RM Howard, R Conway, AJ Harrison Sports biomechanics 16 (4), 463-484, 2017 | 26 | 2017 |
A classification system for delirium subtyping with the use of a commercial mobility monitor A Godfrey, R Conway, M Leonard, D Meagher, G Ólaighin Gait & posture 30 (2), 245-252, 2009 | 26 | 2009 |
New CRT-based RNS converter using restricted moduli set R Conway, J Nelson IEEE Transactions on Computers 52 (5), 572-578, 2003 | 26 | 2003 |
An objective measure of noseband tightness and its measurement using a novel digital tightness gauge O Doherty, T Conway, R Conway, G Murray, V Casey PLoS One 12 (1), e0168996, 2017 | 25 | 2017 |
Modified overlap technique using Fermat and Mersenne transforms R Conway IEEE Transactions on Circuits and Systems II: Express Briefs 53 (8), 632-636, 2006 | 25 | 2006 |
Razor based programmable truncated multiply and accumulate, energy-reduction for efficient digital signal processing M De la Guia Solaz, R Conway IEEE Transactions on Very Large Scale Integration (VLSI) Systems 23 (1), 189-193, 2014 | 24 | 2014 |
Estimation of force during vertical jumps using body fixed accelerometers R Howard, R Conway, AJ Harrison IET Digital Library, 2014 | 24 | 2014 |
OroPress a new wireless tool for measuring oro-lingual pressures: a pilot study in healthy adults J McCormack, V Casey, R Conway, J Saunders, A Perry Journal of NeuroEngineering and Rehabilitation 12, 1-9, 2015 | 21 | 2015 |
A continuous wavelet transform and classification method for delirium motoric subtyping A Godfrey, R Conway, M Leonard, D Meagher, GM Ólaighin IEEE Transactions on Neural Systems and Rehabilitation Engineering 17 (3 …, 2009 | 20 | 2009 |
Real-time low-energy fall detection algorithm with a Programmable Truncated MAC M de la Guia Solaz, A Bourke, R Conway, J Nelson, G ÓLaighin 2010 Annual International Conference of the IEEE Engineering in Medicine and …, 2010 | 17 | 2010 |