Precise radiochromic film dosimetry using a flat‐bed document scanner S Devic, J Seuntjens, E Sham, EB Podgorsak, CR Schmidtlein, AS Kirov, ... Medical physics 32 (7Part1), 2245-2253, 2005 | 774 | 2005 |
Radiochromic film dosimetry: past, present, and future S Devic Physica medica 27 (3), 122-134, 2011 | 484 | 2011 |
Reference radiochromic film dosimetry: review of technical aspects S Devic, N Tomic, D Lewis Physica Medica 32 (4), 541-556, 2016 | 384 | 2016 |
Dosimetric properties of improved GafChromic films for seven different digitizers S Devic, J Seuntjens, G Hegyi, EB Podgorsak, CG Soares, AS Kirov, I Ali, ... Medical physics 31 (9), 2392-2401, 2004 | 368 | 2004 |
Accurate skin dose measurements using radiochromic film in clinical applications S Devic, J Seuntjens, W Abdel‐Rahman, M Evans, M Olivares, ... Medical physics 33 (4), 1116-1124, 2006 | 289 | 2006 |
MRI simulation for radiotherapy treatment planning S Devic Medical physics 39 (11), 6701-6711, 2012 | 192 | 2012 |
Warburg effect-a consequence or the cause of carcinogenesis? S Devic Journal of Cancer 7 (7), 817, 2016 | 177 | 2016 |
Optimizing the dynamic range extension of a radiochromic film dosimetry system S Devic, N Tomic, CG Soares, EB Podgorsak Medical physics 36 (2), 429-437, 2009 | 154 | 2009 |
Sensitivity study for CT image use in Monte Carlo treatment planning F Verhaegen, S Devic Physics in Medicine & Biology 50 (5), 937, 2005 | 148 | 2005 |
Absorption spectra time evolution of EBT‐2 model GAFCHROMIC™ film S Devic, S Aldelaijan, H Mohammed, N Tomic, LH Liang, F DeBlois, ... Medical physics 37 (5), 2207-2214, 2010 | 144 | 2010 |
On two‐parameter models of photon cross sections: application to dual‐energy CT imaging JF Williamson, S Li, S Devic, BR Whiting, FA Lerma Medical physics 33 (11), 4115-4129, 2006 | 119 | 2006 |
Erythropoietin induces cancer cell resistance to ionizing radiation and to cisplatin AI Belenkov, G Shenouda, E Rizhevskaya, D Cournoyer, JP Belzile, ... Molecular cancer therapeutics 3 (12), 1525-1532, 2004 | 117 | 2004 |
Dosimetric and microdosimetric study of contrast-enhanced radiotherapy with kilovolt x-rays F Verhaegen, B Reniers, F Deblois, S Devic, J Seuntjens, D Hristov Physics in Medicine & Biology 50 (15), 3555, 2005 | 107 | 2005 |
Improving the energy response of external beam therapy (EBT) GafChromicTM dosimetry films at low energies (≤100 keV) H Bekerat, S Devic, F DeBlois, K Singh, A Sarfehnia, J Seuntjens, S Shih, ... Medical physics 41 (2), 022101, 2014 | 104 | 2014 |
Absorption spectroscopy of ebt model film S Devic, N Tomic, Z Pang, J Seuntjens, EB Podgorsak, CG Soares Medical physics 34 (1), 112-118, 2007 | 100 | 2007 |
High-dose-rate endorectal brachytherapy in the treatment of locally advanced rectal carcinoma: technical aspects T Vuong, S Devic, B Moftah, M Evans, EB Podgorsak Brachytherapy 4 (3), 230-235, 2005 | 96 | 2005 |
Linearization of dose–response curve of the radiochromic film dosimetry system S Devic, N Tomic, S Aldelaijan, F DeBlois, J Seuntjens, MF Chan, D Lewis Medical physics 39 (8), 4850-4857, 2012 | 92 | 2012 |
High dose rate endorectal brachytherapy as a neoadjuvant treatment for patients with resectable rectal cancer T Vuong, S Devic, E Podgorsak Clinical Oncology 19 (9), 701-705, 2007 | 91 | 2007 |
Reference radiochromic film dosimetry in kilovoltage photon beams during CBCT image acquisition N Tomic, S Devic, F DeBlois, J Seuntjens Medical physics 37 (3), 1083-1092, 2010 | 90 | 2010 |
Sensitivity of linear CCD array based film scanners used for film dosimetry S Devic, YZ Wang, N Tomic, EB Podgorsak Medical physics 33 (11), 3993-3996, 2006 | 89 | 2006 |