Follow
Benjamin Zahneisen
Benjamin Zahneisen
Research Associate, Stanford University
Verified email at stanford.edu
Title
Cited by
Cited by
Year
Tracking dynamic resting-state networks at higher frequencies using MR-encephalography
HL Lee, B Zahneisen, T Hugger, P LeVan, J Hennig
Neuroimage 65, 216-222, 2013
1752013
Single shot whole brain imaging using spherical stack of spirals trajectories
J Assländer, B Zahneisen, T Hugger, M Reisert, HL Lee, P LeVan, ...
Neuroimage 73, 59-70, 2013
1252013
Single shot concentric shells trajectories for ultra fast fMRI
B Zahneisen, T Hugger, KJ Lee, P LeVan, M Reisert, HL Lee, J Assländer, ...
Magnetic resonance in medicine 68 (2), 484-494, 2012
1052012
Three‐dimensional Fourier encoding of simultaneously excited slices: generalized acquisition and reconstruction framework
B Zahneisen, BA Poser, T Ernst, VA Stenger
Magnetic resonance in medicine 71 (6), 2071-2081, 2014
932014
Three‐dimensional MR‐encephalography: fast volumetric brain imaging using rosette trajectories
B Zahneisen, T Grotz, KJ Lee, S Ohlendorf, M Reisert, M Zaitsev, J Hennig
Magnetic resonance in medicine 65 (5), 1260-1268, 2011
832011
SENSE and simultaneous multislice imaging
B Zahneisen, T Ernst, BA Poser
Magnetic resonance in medicine 74 (5), 1356-1362, 2015
732015
Fast fMRI provides high statistical power in the analysis of epileptic networks
J Jacobs, J Stich, B Zahneisen, J Assländer, G Ramantani, ...
Neuroimage 88, 282-294, 2014
712014
Fast undersampled functional magnetic resonance imaging using nonlinear regularized parallel image reconstruction
T Hugger, B Zahneisen, P LeVan, KJ Lee, HL Lee, M Zaitsev, J Hennig
PLoS One 6 (12), e28822, 2011
602011
Extended hybrid-space SENSE for EPI: Off-resonance and eddy current corrected joint interleaved blip-up/down reconstruction
B Zahneisen, M Aksoy, J Maclaren, C Wuerslin, R Bammer
NeuroImage 153, 97-108, 2017
532017
Gradient‐echo and CRAZED imaging for minute detection of Alzheimer plaques in an APPV717I × ADAM10‐dn mouse model
C Faber, B Zahneisen, F Tippmann, A Schroeder, F Fahrenholz
Magnetic Resonance in Medicine: An Official Journal of the International …, 2007
462007
Simultaneous Multi-Slice fMRI using spiral trajectories
B Zahneisen, BA Poser, T Ernst, AV Stenger
Neuroimage 92, 8-18, 2014
452014
Sensitivity to local dipole fields in the CRAZED experiment: an approach to bright spot MRI
C Faber, C Heil, B Zahneisen, DZ Balla, R Bowtell
Journal of Magnetic Resonance 182 (2), 315-324, 2006
452006
Prospective motion correction using coil‐mounted cameras: cross‐calibration considerations
J Maclaren, M Aksoy, MB Ooi, B Zahneisen, R Bammer
Magnetic resonance in medicine 79 (4), 1911-1921, 2018
422018
Fast functional brain imaging using constrained reconstruction based on regularization using arbitrary projections
T Grotz, B Zahneisen, A Ella, M Zaitsev, J Hennig
Magnetic Resonance in Medicine: An Official Journal of the International …, 2009
422009
Quantification and correction of respiration induced dynamic field map changes in fMRI using 3D single shot techniques
B Zahneisen, J Assländer, P LeVan, T Hugger, M Reisert, T Ernst, ...
Magnetic resonance in medicine 71 (3), 1093-1102, 2014
382014
Prospective motion correction of segmented diffusion weighted EPI
M Herbst, B Zahneisen, B Knowles, M Zaitsev, T Ernst
Magnetic resonance in medicine 74 (6), 1675-1681, 2015
362015
Systems, methods, and devices for removing prospective motion correction from medical imaging scans
TM Ernst, BA Zahneisen, NY Jeffrey
US Patent 10,004,462, 2018
322018
Optical tracking with two markers for robust prospective motion correction for brain imaging
A Singh, B Zahneisen, B Keating, M Herbst, L Chang, M Zaitsev, T Ernst
Magnetic Resonance Materials in Physics, Biology and Medicine 28, 523-534, 2015
312015
Rotated stack‐of‐spirals partial acquisition for rapid volumetric parallel MRI
W Deng, B Zahneisen, VA Stenger
Magnetic resonance in medicine 76 (1), 127-135, 2016
282016
Reverse retrospective motion correction
B Zahneisen, B Keating, A Singh, M Herbst, T Ernst
Magnetic resonance in medicine 75 (6), 2341-2349, 2016
232016
The system can't perform the operation now. Try again later.
Articles 1–20