Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage M Bianchi, G Marom, RP Ghosh, OM Rotman, P Parikh, L Gruberg, ... Biomechanics and modeling in mechanobiology 18 (2), 435-451, 2019 | 119 | 2019 |
Principles of TAVR valve design, modelling, and testing OM Rotman, M Bianchi, RP Ghosh, B Kovarovic, D Bluestein Expert review of medical devices 15 (11), 771-791, 2018 | 93 | 2018 |
Numerical evaluation of transcatheter aortic valve performance during heart beating and its post-deployment fluid–structure interaction analysis RP Ghosh, G Marom, M Bianchi, K D’souza, W Zietak, D Bluestein Biomechanics and modeling in mechanobiology 19 (5), 1725-1740, 2020 | 69 | 2020 |
Effect of Balloon‐Expandable Transcatheter Aortic Valve Replacement Positioning: A Patient‐Specific Numerical Model M Bianchi, G Marom, RP Ghosh, HA Fernandez, JR Taylor Jr, MJ Slepian, ... Artificial organs 40 (12), E292-E304, 2016 | 68 | 2016 |
Patient-Specific Bicuspid Aortic Valve Biomechanics: A Magnetic Resonance Imaging Integrated Fluid–Structure Interaction Approach M Emendi, F Sturla, RP Ghosh, M Bianchi, F Piatti, FR Pluchinotta, ... Annals of Biomedical Engineering 49 (2), 627-641, 2021 | 46 | 2021 |
Comparative Fluid–Structure Interaction Analysis of Polymeric Transcatheter and Surgical Aortic Valves' Hemodynamics and Structural Mechanics RP Ghosh, G Marom, OM Rotman, MJ Slepian, S Prabhakar, M Horner, ... Journal of biomechanical engineering 140 (12), 2018 | 46 | 2018 |
Aspirin has limited ability to modulate shear-mediated platelet activation associated with elevated shear stress of ventricular assist devices L Valerio, PL Tran, J Sheriff, W Brengle, R Ghosh, WC Chiu, A Redaelli, ... Thrombosis Research 140, 110-117, 2016 | 38 | 2016 |
Simulation of transcatheter aortic valve replacement in patient-specific aortic roots: effect of crimping and positioning on device performance M Bianchi, RP Ghosh, G Marom, MJ Slepian, D Bluestein 2015 37th Annual International Conference of the IEEE Engineering in …, 2015 | 22 | 2015 |
Assessment of Paravalvular Leak Severity and Thrombogenic Potential in Transcatheter Bicuspid Aortic Valve Replacements Using Patient-Specific Computational Modeling SB Anam, BJ Kovarovic, RP Ghosh, M Bianchi, A Hamdan, R Haj-Ali, ... Journal of cardiovascular translational research, 1-11, 2021 | 19 | 2021 |
Validating In Silico and In Vitro Patient-Specific Structural and Flow Models with Transcatheter Bicuspid Aortic Valve Replacement Procedure SB Anam, BJ Kovarovic, RP Ghosh, M Bianchi, A Hamdan, R Haj-Ali, ... Cardiovascular Engineering and Technology, 1-17, 2022 | 10 | 2022 |
Patient-Specific Computational Approach for Trans Catheter Aortic Valve Replacement (TAVR): Pre-Procedural Planning for Enhancing Performance and Clinical Outcomes RP Ghosh, M Bianchi, G Marom, OM Rotman, B Kovarovic, D Bluestein Molecular & Cellular Biomechanics 16, 12, 2019 | 2 | 2019 |
P6317 Simulation of transcatheter aortic valve performance in a beating heart R Ghosh, G Marom, M Bianchi, V Kashirin, P Sridhar, K D'Souza, W Zietak, ... European Heart Journal 39 (suppl_1), ehy566. P6317, 2018 | 1 | 2018 |
Patient-Specific Numerical Model of Calcific Aortic Stenosis and Its Treatment by Balloon-Expandable Transcatheter Aortic Valve: Effect of Positioning on the Anchorage G Marom, M Bianchi, RP Ghosh, D Bluestein Computer Methods in Biomechanics and Biomedical Engineering, 259-263, 2018 | 1 | 2018 |
Transcatheter aortic valve replacement model: crimping and deploying in patient-pathology specific roots M Bianchi, RP Ghosh, D Das, G Marom, T Claiborne, M Slepian, ... Summer Biomechanics, Bioengineering and Biotransport Conference. Utah …, 2015 | 1 | 2015 |
O-033 Computational fluid dynamics analysis to compare flow diversion efficacy of evolve and pipeline devices C Sadasivan, B Kovarovic, R Ghosh, D Fiorella Journal of NeuroInterventional Surgery 12 (Suppl 1), A22-A23, 2020 | | 2020 |
Correction to: Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage M Bianchi, G Marom, RP Ghosh, OM Rotman, P Parikh, L Gruberg, ... Biomechanics and Modeling in Mechanobiology, 1-1, 2020 | | 2020 |
Fluid-structure Interaction Simulations to Evaluate Prosthetic and Diseased Aortic Valves’ Hemodynamics and Structural Mechanics RP Ghosh State University of New York at Stony Brook, 2019 | | 2019 |
Simulation of transcatheter aortic valve performance in a beating heart R Ghosh, G Marom, M Bianchi, V Kashirin, P Sridhar, K D'Souza, W Zietak, ... EUROPEAN HEART JOURNAL 39, 1320-1321, 2018 | | 2018 |
EVALUATION OF NOVEL POLYMERIC TRANSCATHETER AND SURGICAL AORTIC VALVES WITH FLUID-STRUCTURE INTERACTION MODELS AND EXPERIMENTAL ANALYSIS RP Ghosh, G Marom, OM Rotman, M Bianchi, S Prabhakar, M Horner, ... | | 2017 |
Post-TAVR Left Bundle Branch Blockage in Bicuspid Aortic Valve Patients: Analyzing Clinical Risk using Patient-specific Computational Modeling S Anam, R Helbock, M Bianchi, B Kovarovic, R Ghosh, A Hamdan, ... | | |