Energy impact evaluation of different low-GWP alternatives to replace R134a in a beverage cooler. Experimental analysis and optimization for the pure refrigerants R152a … D Sánchez, A Andreu-Nácher, D Calleja-Anta, R Llopis, R Cabello Energy Conversion and Management 256, 115388, 2022 | 65 | 2022 |
R-454C, R-459B, R-457A and R-455A as low-GWP replacements of R-404A: Experimental evaluation and optimization R Llopis, D Calleja-Anta, D Sánchez, L Nebot-Andrés, J Catalán-Gil, ... International Journal of Refrigeration 106, 133-143, 2019 | 63 | 2019 |
Thermodynamic screening of alternative refrigerants for R290 and R600a D Calleja-Anta, L Nebot-Andrés, J Catalán-Gil, D Sánchez, R Cabello, ... Results in Engineering 5, 100081, 2020 | 62 | 2020 |
Experimental determination of the optimum working conditions of a transcritical CO2 refrigeration plant with integrated mechanical subcooling L Nebot-Andrés, J Catalán-Gil, D Sánchez, D Calleja-Anta, R Cabello, ... International Journal of Refrigeration 113, 266-275, 2020 | 61 | 2020 |
Experimental assessment of dedicated and integrated mechanical subcooling systems vs parallel compression in transcritical CO2 refrigeration plants L Nebot-Andres, D Calleja-Anta, D Sánchez, R Cabello, R Llopis Energy Conversion and Management 252, 115051, 2022 | 46 | 2022 |
Experimental determination of the optimum intermediate and gas-cooler pressures of a commercial transcritical CO2 refrigeration plant with parallel compression L Nebot-Andrés, D Sánchez, D Calleja-Anta, R Cabello, R Llopis Applied Thermal Engineering 189, 116671, 2021 | 42 | 2021 |
TEWI analysis of a stand-alone refrigeration system using low-GWP fluids with leakage ratio consideration R Llopis, D Calleja-Anta, A Maiorino, L Nebot-Andrés, D Sánchez, ... International Journal of Refrigeration 118, 279-289, 2020 | 40 | 2020 |
Experimental analysis and optimization of an R744 transcritical cycle working with a mechanical subcooling system D Sánchez, J Catalán-Gil, R Cabello, D Calleja-Anta, R Llopis, ... Energies 13 (12), 3204, 2020 | 32 | 2020 |
Experimental determination of the optimum working conditions of a commercial transcritical CO2 refrigeration plant with a R-152a dedicated mechanical subcooling. L Nebot-Andrés, D Sánchez, D Calleja-Anta, R Cabello, R Llopis International Journal of Refrigeration 121, 258-268, 2021 | 31 | 2021 |
Energy impact of the Internal Heat Exchanger in a horizontal freezing cabinet. Experimental evaluation with the R404A low-GWP alternatives R454C, R455A, R468A, R290 and R1270 R Cabello, D Sánchez, R Llopis, A Andreu-Nacher, D Calleja-Anta International Journal of Refrigeration 137, 22-33, 2022 | 30 | 2022 |
Improvements in CO2 Booster Architectures with Different Economizer Arrangements J Catalán-Gil, L Nebot-Andres, D Sánchez, R Llopis, R Cabello, ... Energies 13 (5), 1271, 2020 | 23 | 2020 |
A3 and A2 refrigerants: border determination and hunt for A2 low-GWP blends D Calleja-Anta, L Nebot-Andres, R Cabello, D Sánchez, R Llopis International Journal of Refrigeration 134, 86-94, 2022 | 22 | 2022 |
Thermodynamic Analysis of a CO2 Refrigeration Cycle with Integrated Mechanical Subcooling L Nebot-Andrés, D Calleja-Anta, D Sánchez, R Cabello, R Llopis Energies 13 (1), 4, 2019 | 16 | 2019 |
Experimental evaluation of the desuperheater influence in a CO2 booster refrigeration facility J Catalán-Gil, D Sánchez, R Cabello, R Llopis, L Nebot-Andrés, ... Applied Thermal Engineering 168, 114785, 2020 | 13 | 2020 |
Energy evaluation of a low temperature commercial refrigeration plant working with the new low-GWP blend R468A as drop-in of R404A R Cabello, D Sánchez, R Llopis, L Nebot-Andrés, D Calleja-Anta International Journal of Refrigeration 127, 1-11, 2021 | 12 | 2021 |
Experimental assessment of different extraction points for the integrated mechanical subcooling system of a CO2 transcritical plant L Nebot-Andrés, D Calleja-Anta, C Fossi, D Sánchez, R Cabello, R Llopis International Journal of Refrigeration 136, 8-16, 2022 | 10 | 2022 |
Energy performance assessment of an auto-cascade cycle for ultra-low temperatures with the pair R1150-R600a R Llopis, M Martínez-Ángeles, D Calleja-Anta, L Nebot-Andrés Applied Thermal Engineering 240, 122255, 2024 | 9 | 2024 |
Energy improvements in a stand-alone transcritical refrigeration system using a low-GWP mixture of CO2/R1270 D Sánchez, R Cabello, R Llopis, J Catalán-Gil, L Nebot-Andrés, ... 25th IIR International Congress of Refrigeration. Montréal, Canada, 2019 | 9 | 2019 |
Drop-in substitutes for R-600a. Experimental evaluation and optimization of a commercial fridge D Calleja-Anta, L Nebot-Andres, D Sánchez, R Cabello, R Llopis Applied Thermal Engineering 211, 118490, 2022 | 8 | 2022 |
Optimizing R152a/R600 and R290/R600 mixtures for superior energy performance in vapor compression systems: Promising alternatives to Isobutane (R600a) D Calleja-Anta, M Martínez-Ángeles, L Nebot-Andres, D Sánchez, ... Applied Thermal Engineering 247, 123070, 2024 | 6 | 2024 |