Follow
John J. van den Dobbelsteen
John J. van den Dobbelsteen
Full Professor at Delft University of Technology
Verified email at vandendobbelsteen.nl
Title
Cited by
Cited by
Year
Needle–tissue interaction forces–A survey of experimental data
DJ van Gerwen, J Dankelman, JJ van den Dobbelsteen
Medical engineering & physics 34 (6), 665-680, 2012
3042012
Three-dimensional needle shape reconstruction using an array of fiber bragg grating sensors
RJ Roesthuis, M Kemp, JJ van den Dobbelsteen, S Misra
IEEE/ASME transactions on mechatronics 19 (4), 1115-1126, 2013
2962013
Sensory integration does not lead to sensory calibration
JBJ Smeets, JJ van den Dobbelsteen, DDJ de Grave, RJ van Beers, ...
Proceedings of the National Academy of Sciences 103 (49), 18781-18786, 2006
2412006
Design choices in needle steering—A review
NJ Van De Berg, DJ Van Gerwen, J Dankelman, JJ Van Den Dobbelsteen
IEEE/ASME Transactions on Mechatronics 20 (5), 2172-2183, 2014
1612014
Force feedback and basic laparoscopic skills
MK Chmarra, J Dankelman, JJ van den Dobbelsteen, FW Jansen
Surgical endoscopy 22, 2140-2148, 2008
1212008
Force measurement platform for training and assessment of laparoscopic skills
T Horeman, SP Rodrigues, FW Jansen, J Dankelman, ...
Surgical endoscopy 24, 3102-3108, 2010
1112010
Forces applied to the maxillary incisors during video-assisted intubation
RA Lee, AAJ van Zundert, RLJG Maassen, RJ Willems, LP Beeke, ...
Anesthesia & Analgesia 108 (1), 187-191, 2009
1102009
Sterilization of disposable face masks by means of standardized dry and steam sterilization processes; an alternative in the fight against mask shortages due to COVID-19
P De Man, B van Straten, J van den Dobbelsteen, A Van Der Eijk, ...
Journal of Hospital Infection 105 (2), 356-357, 2020
1062020
Design of an actively controlled steerable needle with tendon actuation and FBG-based shape sensing
NJ van de Berg, J Dankelman, JJ van den Dobbelsteen
Medical engineering & physics 37 (6), 617-622, 2015
1042015
Assessment of laparoscopic skills based on force and motion parameters
T Horeman, J Dankelman, FW Jansen, JJ van den Dobbelsteen
IEEE Transactions on Biomedical Engineering 61 (3), 805-813, 2013
992013
Accuracy of needle position measurements using fiber Bragg gratings
K Henken, D Van Gerwen, J Dankelman, J Van Den Dobbelsteen
Minimally Invasive Therapy & Allied Technologies 21 (6), 408-414, 2012
952012
Error Analysis of FBG-Based Shape Sensors for Medical Needle Tracking
KR Henken, J Dankelman, JJ van den Dobbelsteen, LK Cheng, ...
Transactions on Mechatronics, 1-9, 2013
932013
Visual force feedback improves knot-tying security
T Horeman, MD Blikkendaal, D Feng, A van Dijke, FW Jansen, ...
Journal of surgical education 71 (1), 133-141, 2014
772014
Force parameters for skills assessment in laparoscopy
T Horeman, SP Rodrigues, FW Jansen, J Dankelman, ...
IEEE Transactions on Haptics 5 (4), 312-322, 2011
752011
Endpoints of arm movements to visual targets
JJ van den Dobbelsteen, E Brenner, JB Smeets
Experimental Brain Research 138, 279-287, 2001
722001
Visual force feedback in laparoscopic training
T Horeman, SP Rodrigues, JJ van den Dobbelsteen, FW Jansen, ...
Surgical endoscopy 26, 242-248, 2012
692012
Friction dynamics of trocars
JJ Van den Dobbelsteen, A Schooleman, J Dankelman
Surgical endoscopy 21, 1338-1343, 2007
612007
Needle placement errors: do we need steerable needles in interventional radiology?
TL De Jong, NJ Van De Berg, L Tas, A Moelker, J Dankelman, ...
Medical Devices: Evidence and Research, 259-265, 2018
582018
The art of electrosurgery: trainees and experts
FC Meeuwsen, ACP Guédon, EA Arkenbout, M van der Elst, J Dankelman, ...
Surgical innovation 24 (4), 373-378, 2017
572017
PVA matches human liver in needle-tissue interaction
TL de Jong, LH Pluymen, DJ van Gerwen, GJ Kleinrensink, J Dankelman, ...
Journal of the mechanical behavior of biomedical materials 69, 223-228, 2017
532017
The system can't perform the operation now. Try again later.
Articles 1–20