Executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus DB Sacks, M Arnold, GL Bakris, DE Bruns, AR Horvath, MS Kirkman, ... Clinical chemistry 57 (6), 793-798, 2011 | 1492* | 2011 |
Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus DB Sacks, M Arnold, GL Bakris, DE Bruns, AR Horvath, MS Kirkman, ... Clinical chemistry 57 (6), e1-e47, 2011 | 1340 | 2011 |
Determination of physiological levels of glucose in an aqueous matrix with digitally filtered Fourier transform near-infrared spectra MA Arnold, GW Small Analytical Chemistry 62 (14), 1457-1464, 1990 | 265 | 1990 |
Genetic algorithm-based method for selecting wavelengths and model size for use with partial least-squares regression: application to near-infrared spectroscopy AS Bangalore, RE Shaffer, GW Small, MA Arnold Analytical Chemistry 68 (23), 4200-4212, 1996 | 262 | 1996 |
Ion-selective electrodes MA Arnold, ME Meyerhoff Analytical chemistry 56 (5), 20-48, 1984 | 262 | 1984 |
Measurement of glucose and other analytes in undiluted human serum with near-infrared transmission spectroscopy KH Hazen, MA Arnold, GW Small Analytica Chimica Acta 371 (2-3), 255-267, 1998 | 232 | 1998 |
Noninvasive glucose sensing MA Arnold, GW Small Analytical Chemistry 77 (17), 5429-5439, 2005 | 231 | 2005 |
Near-infrared spectroscopic measurement of physiological glucose levels in variable matrices of protein and triglycerides S Pan, H Chung, MA Arnold, GW Small Analytical chemistry 68 (7), 1124-1135, 1996 | 220 | 1996 |
Evaluation of measurement sites for noninvasive blood glucose sensing with near-infrared transmission spectroscopy JJ Burmeister, MA Arnold clinical chemistry 45 (9), 1621-1627, 1999 | 209 | 1999 |
Fiber-optic chemical sensors MA Arnold Analytical chemistry 64 (21), 1015A-1025A, 1992 | 203 | 1992 |
Comparison of combination and first overtone spectral regions for near-infrared calibration models for glucose and other biomolecules in aqueous solutions J Chen, MA Arnold, GW Small Analytical chemistry 76 (18), 5405-5413, 2004 | 192 | 2004 |
Temperature-insensitive near-infrared spectroscopic measurement of glucose in aqueous solutions KH Hazen, MA Arnold, GW Small Applied Spectroscopy 48 (4), 477-483, 1994 | 191 | 1994 |
Recent advances in the development and analytical applications of biosensing probes MA Arnold, ME Meyerhoff Critical Reviews in Analytical Chemistry 20 (3), 149-196, 1988 | 185 | 1988 |
Strategies for coupling digital filtering with partial least-squares regression: Application to the determination of glucose in plasma by Fourier-transform near-infrared … GW Small, MA Arnold, LA Marquardt Analytical chemistry 65 (22), 3279-3289, 1993 | 178 | 1993 |
In vivo near-infrared spectroscopy of rat skin tissue with varying blood glucose levels JT Olesberg, L Liu, VV Zee, MA Arnold Analytical chemistry 78 (1), 215-223, 2006 | 177 | 2006 |
Phantom glucose calibration models from simulated noninvasive human near-infrared spectra MA Arnold, JJ Burmeister, GW Small Analytical chemistry 70 (9), 1773-1781, 1998 | 174 | 1998 |
Tunable laser diode system for noninvasive blood glucose measurements JT Olesberg, MA Arnold, C Mermelstein, J Schmitz, J Wagner Applied spectroscopy 59 (12), 1480-1484, 2005 | 173 | 2005 |
Simultaneous measurements of glucose, glutamine, ammonia, lactate, and glutamate in aqueous solutions by near-infrared spectroscopy H Chung, MA Arnold, M Rhiel, DW Murhammer Applied Spectroscopy 50 (2), 270-276, 1996 | 171 | 1996 |
Selectivity of membrane electrodes based on derivatives of dibenzyltin dichloride SA Glazier, MA Arnold Analytical chemistry 63 (8), 754-759, 1991 | 170 | 1991 |
Position statement executive summary: guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus DB Sacks, M Arnold, GL Bakris, DE Bruns, AR Horvath, MS Kirkman, ... Diabetes care 34 (6), 1419-1423, 2011 | 169 | 2011 |