A retrospective dosimetric comparison of TG43 and a commercially available MBDCA for an APBI brachytherapy patient cohort K Zourari, T Major, A Herein, V Peppa, C Polgár, P Papagiannis Physica Medica 31 (7), 669-676, 2015 | 39 | 2015 |
On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning EP Pappas, E Zoros, A Moutsatsos, V Peppa, K Zourari, P Karaiskos, ... Physics in Medicine & Biology 62 (10), 4160, 2017 | 28 | 2017 |
On the use of a novel Ferrous Xylenol-orange gelatin dosimeter for HDR brachytherapy commissioning and quality assurance testing EP Pappas, V Peppa, CJ Hourdakis, P Karaiskos, P Papagiannis Physica Medica 45, 162-169, 2018 | 25 | 2018 |
BrachyGuide: a brachytherapy‐dedicated DICOM RT viewer and interface to Monte Carlo simulation software E Pantelis, V Peppa, V Lahanas, E Pappas, P Papagiannis Journal of applied clinical medical physics 16 (1), 208-218, 2015 | 24 | 2015 |
On the impact of improved dosimetric accuracy on head and neck high dose rate brachytherapy V Peppa, E Pappas, T Major, Z Takácsi-Nagy, E Pantelis, P Papagiannis Radiotherapy and Oncology 120 (1), 92-97, 2016 | 23 | 2016 |
Dosimetric and radiobiological comparison of TG-43 and Monte Carlo calculations in 192Ir breast brachytherapy applications V Peppa, EP Pappas, P Karaiskos, T Major, C Polgár, P Papagiannis Physica Medica 32 (10), 1245-1251, 2016 | 17 | 2016 |
A user-oriented procedure for the commissioning and quality assurance testing of treatment planning system dosimetry in high-dose-rate brachytherapy V Peppa, E Pantelis, E Pappas, V Lahanas, C Loukas, P Papagiannis Brachytherapy 15 (2), 252-262, 2016 | 17 | 2016 |
PO-0970: Tissue segmentation significance for individualized 192Ir brachytherapy dosimetry V Peppa, K Zourari, E Pantelis, P Papagiannis Radiotherapy and Oncology 106, S374, 2013 | 7 | 2013 |
A MC‐based anthropomorphic test case for commissioning model‐based dose calculation in interstitial breast 192‐Ir HDR brachytherapy V Peppa, RM Thomson, SA Enger, GP Fonseca, C Lee, JNE Lucero, ... Medical Physics 50 (7), 4675-4687, 2023 | 5 | 2023 |
Comparison and Evaluation of Different Radiotherapy Techniques Using Biodosimetry Based on Cytogenetics A Nikolakopoulou, V Peppa, A Alexiou, G Pissakas, G Terzoudi, ... Cancers 14 (1), 146, 2021 | 5 | 2021 |
A phantom based evaluation of the clinical imaging performance of electronic portal imaging devices MK Tzomakas, V Peppa, A Alexiou, G Karakatsanis, A Episkopakis, ... Heliyon 9 (10), 2023 | 4 | 2023 |
Time resolved dose rate distributions in brachytherapy V Peppa, EP Pappas, P Karaiskos, P Papagiannis Physica Medica 41, 13-19, 2017 | 4 | 2017 |
On the potential of 2D ion chamber arrays for high-dose rate remote afterloading brachytherapy quality assurance A Lekatou, V Peppa, P Karaiskos, E Pantelis, P Papagiannis Physics in Medicine & Biology 67 (8), 085011, 2022 | 3 | 2022 |
Evaluation of AI vs. Clinical Experts SBRT-Thorax Computed Tomography OARs Delineation S Stathakis, G Pissakas, A Alexiou, B Bertrand, PY Bondiau, L Claude, ... International Journal of Radiation Oncology, Biology, Physics 114 (3), e102-e103, 2022 | 2 | 2022 |
Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data K Zourari, V Peppa, F Ballester, FA Siebert, P Papagiannis Medical Physics 41 (4), 043901, 2014 | 2 | 2014 |
Dose delivery uncertainties assessment in the field junction region of craniospinal irradiation with Volumetric Modulated Arc Therapy using a robustness index and experimental … V Peppa, E Zoros, A Alexiou, G Pissakas, P Karaiskos Plos one 19 (11), e0313260, 2024 | 1 | 2024 |
SU‐F‐BRA‐11: An Experimental Commissioning Test of Brachytherapy MBDCA Dosimetry, Based On a Commercial Radiochromic Gel/optical CT System E Pappas, P Karaiskos, K Zourari, V Peppa, P Papagiannis Medical Physics 42 (6Part26), 3536-3536, 2015 | 1 | 2015 |
A QA procedure for brachytherapy TPS employing model based dose calculations, based on Monte Carlo simulation and end user oriented tools V Peppa, E Pappas, E Pantelis, P Papagiannis Physica Medica: European Journal of Medical Physics 30, e68, 2014 | 1 | 2014 |
Beam quality correction factors for dose measurements around 192Ir brachytherapy sources Z Thrapsanioti, V Peppa, CJ Hourdakis, P Karaiskos, A Lekatou, ... Journal of Applied Clinical Medical Physics 26 (1), e14575, 2025 | | 2025 |
Image Quality and Information Parameters of Electronic Portal Imaging Devices MK Tzomakas, V Peppa, A Alexiou, G Karakatsanis, A Episkopakis, ... Applied Sciences 14 (22), 10260, 2024 | | 2024 |