Computational fluid dynamic analysis following recurrence of cerebral aneurysm after coil embolization K Irie, H Anzai, M Kojima, N Honjo, M Ohta, Y Hirose, M Negoro Asian journal of neurosurgery 7 (3), 109, 2012 | 35 | 2012 |
Optimization of strut placement in flow diverter stents for four different aneurysm configurations H Anzai, JL Falcone, B Chopard, T Hayase, M Ohta Journal of biomechanical engineering 136 (6), 061006, 2014 | 34 | 2014 |
Multiobjective design optimization of stent geometry with wall deformation for triangular and rectangular struts NK Putra, PS Palar, H Anzai, K Shimoyama, M Ohta Medical & biological engineering & computing 57 (1), 15-26, 2019 | 30 | 2019 |
Towards the patient-specific design of flow diverters made from helix-like wires: an optimization study M Zhang, H Anzai, B Chopard, M Ohta Biomedical engineering online 15 (2), 159, 2016 | 29 | 2016 |
Optimization of flow diverters for cerebral aneurysms H Anzai, M Ohta, JL Falcone, B Chopard Journal of Computational Science 3 (1-2), 1-7, 2012 | 29 | 2012 |
Effects of Elasticity on Wall Shear Stress in Patient-Specific Aneurysm of Cerebral Artery R Yamaguchi, T Kotani, G Tanaka, S Tupin, K Osman, NS Shafii, ... | 15 | 2019 |
Parametric study of porous media as substitutes for flow-diverter stent M Ohta, H Anzai, Y Miura, T Nakayama Biomaterials and Biomechanics in Bioengineering 2 (2), 111-125, 2015 | 14 | 2015 |
In vitro strain measurements in cerebral aneurysm models for cyber‐physical diagnosis C Shi, M Kojima, H Anzai, C Tercero, S Ikeda, M Ohta, T Fukuda, F Arai, ... The International Journal of Medical Robotics and Computer Assisted Surgery …, 2013 | 13 | 2013 |
Combinational optimization of strut placement for intracranial stent using a realistic aneurysm H Anzai, B Chopard, M Ohta Journal of Flow Control, Measurement & Visualization 2 (02), 67, 2014 | 10 | 2014 |
Structural Design and Numerical Analysis of a Novel Biodegradable Zinc Alloy Stent K Peng, A Qiao, M Ohta, NK Putra, X Cui, Y Mu, H Anzai CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES 117 (1), 17-28, 2018 | 9 | 2018 |
Comparative Study Between Different Strut’s Cross Section Shape on Minimizing Low Wall Shear Stress Along Stent Vicinity via Surrogate-Based Optimization NK Putra, PS Palar, H Anzai, K Shimoyama, M Ohta World Congress of Structural and Multidisciplinary Optimisation, 2097-2109, 2017 | 9 | 2017 |
Simulation of hemodynamics in artery with aneurysm and stenosis with different geometric configuration Y LI, H ANZAI, T NAKAYAMA, Y SHIMIZU, Y MIURA, A QIAO, M OHTA Journal of Biomechanical Science and Engineering 9 (1), JBSE0003-JBSE0003, 2014 | 8 | 2014 |
The Effect of 3D Visualization on Optimal Design for Strut Position of Intracranial Stent H Anzai, T Nakayama, Y Takeshima, M Ohta ASME 2010 3rd Joint US-European Fluids Engineering Summer Meeting collocated …, 2010 | 7 | 2010 |
Porosity dependency of an optimized stent design for an intracranial aneurysm H Anzai, Y Yoshida, S Sugiyama, H Endo, Y Matsumoto, M Ohta Technology and Health Care 23 (5), 547-556, 2015 | 5 | 2015 |
Experimental Analysis for the Anisotropic Flows in Cancellous Bone M Ito, S Tupin, H Anzai, A Suzuki, M Ohta ASME 2017 International Mechanical Engineering Congress and Exposition …, 2017 | 4 | 2017 |
Stent design optimization based on Kriging surrogate model under deformed vessel wall: pulsatile inlet flow NK Putra, PS Palar, H Anzai, K Shimoyama, M Ohta 2017 5th International Conference on Instrumentation, Control, and …, 2017 | 4 | 2017 |
Computational Fluid Dynamics Analysis of the Bone Marrow in Cancellous Bone as a Non-Newtonian Fluid M Ohta, W Sakuma, T Nakayama, H Anzai, M Ito, K Sado, S Nakamura ASME 2016 International Mechanical Engineering Congress and Exposition …, 2016 | 3 | 2016 |
Manufacture-Oriented Design Optimisation of a Flow Diverter Stent Using Lattice Boltzmann Method and Simulated Annealing M Zhang, H Anzai, B Chopard, M Ohta 11th World Congress on Structural and Multidisciplinary Optimization, 2015 | 3 | 2015 |
Computational Fluid Dynamics Analysis to Predict Endothelial Cells Migration During Flow Exposure Experiment With Placement of Two Stent Wires NK Putra, Z Wang, H Anzai, M Ohta 2018 40th Annual International Conference of the IEEE Engineering in …, 2018 | 2 | 2018 |
A cyber-physical system for strain measurements in the cerebral aneurysm models C Shi, M Kojima, C Tercero, H Anzai, M Ohta, K Ooe, S Ikeda, T Fukuda, ... 2012 IEEE/RSJ International Conference on Intelligent Robots and Systems …, 2012 | 2 | 2012 |