Follow
Tao Tang
Tao Tang
Guangdong Institute of Intelligence Science and Technology (GDIIST)
Verified email at gdiist.cn
Title
Cited by
Cited by
Year
Body-area powering with human body-coupled power transmission and energy harvesting ICs
J Li, Y Dong, JH Park, L Lin, T Tang, J Yoo
IEEE Transactions on Biomedical Circuits and Systems 14 (6), 1263-1273, 2020
442020
34.5 Human-body-coupled power-delivery and ambient-energy-harvesting ICs for a full-body-area power sustainability
J Li, Y Dong, JH Park, L Lin, T Tang, M Zhang, H Wu, L Zhang, JSY Tan, ...
2020 IEEE International Solid-State Circuits Conference-(ISSCC), 514-516, 2020
322020
A 15-channel orthogonal code chopping instrumentation amplifier for area-efficient, low-mismatch bio-signal acquisition
JH Park, T Tang, L Zhang, KA Ng, GGL Gammad, SC Yen, J Yoo
IEEE Journal of Solid-State Circuits 55 (10), 2771-2780, 2020
302020
A one-shot learning, online-tuning, closed-loop epilepsy management SoC with 0.97 μJ/classification and 97.8% vector-based sensitivity
M Zhang, L Zhang, JH Park, CW Tsai, KA Ng, L Lin, Y Dong, J Li, T Tang, ...
2021 Symposium on VLSI Circuits, 1-2, 2021
292021
A TDM-based 16-channel AFE ASIC with enhanced system-level CMRR for wearable EEG recording with dry electrodes
T Tang, WL Goh, L Yao, Y Gao
IEEE Transactions on Biomedical Circuits and Systems 14 (3), 516-524, 2020
272020
34.6 EEG dust: A BCC-based wireless concurrent recording/transmitting concentric electrode
T Tang, L Yan, JH Park, H Wu, L Zhang, HYB Lee, J Yoo
2020 IEEE International Solid-State Circuits Conference-(ISSCC), 516-518, 2020
272020
An active concentric electrode for concurrent EEG recording and body-coupled communication (BCC) data transmission
T Tang, L Yan, JH Park, H Wu, L Zhang, J Li, Y Dong, BHY Lee, J Yoo
IEEE Transactions on Biomedical Circuits and Systems 14 (6), 1253-1262, 2020
252020
An integrated multi-channel biopotential recording analog front-end IC with area-efficient driven-right-leg circuit
T Tang, WL Goh, L Yao, JH Cheong, Y Gao
IEEE transactions on biomedical circuits and systems 14 (2), 297-304, 2019
222019
Body-coupled power transceiver with node-specific body-area powering
Y Dong, J Li, L Lin, T Tang, JH Park, KA Ng, M Zhang, L Zhang, JSY Tan, ...
ESSCIRC 2021-IEEE 47th European Solid State Circuits Conference (ESSCIRC …, 2021
132021
A 0.012 mm2, ZIN Intrinsic Feedback Capacitor Instrumentation Amplifier for Bio-Potential Recording and Respiratory Monitoring
L Zhang, T Tang, JH Park, J Yoo
2019 IEEE Asian Solid-State Circuits Conference (A-SSCC), 301-304, 2019
132019
A 16-channel TDM analog front-end with enhanced system CMRR for wearable dry EEG recording
T Tang, WL Goh, L Yao, Y Gao
2017 IEEE Asian Solid-State Circuits Conference (A-SSCC), 33-36, 2017
132017
Group-Chopping: An 8-Channel, 0.04% Gain Mismatch, 2.1 µW 0.017 mm2 Instrumentation Amplifier for Bio-Potential Recording
T Tang, JH Park, L Zhang, KA Ng, J Yoo
IEEE Transactions on Biomedical Circuits and Systems 16 (3), 361-371, 2022
122022
An 8-channel 2.1 μ W0.017 mm2 0.04% Gain Mismatch Bio-potential Recording AFE using Group-Chopping Technique
T Tang, J Park, L Zhang, KA Ng, J Yoo
2019 IEEE Custom Integrated Circuits Conference (CICC), 1-4, 2019
82019
Miniaturized Implantable Fluorescence Probes Integrated with Metal–Organic Frameworks for Deep Brain Dopamine Sensing
W Ling, X Shang, C Yu, C Li, K Xu, L Feng, Y Wei, T Tang, X Huang
ACS nano 18 (15), 10596-10608, 2024
72024
An integrated multichannel neural recording analog front-end ASIC with area-efficient driven right leg circuit
T Tang, WL Goh, L Yao, JH Cheong, Y Gao
2017 39th Annual International Conference of the IEEE Engineering in …, 2017
62017
Efficacy of different strategies of responsive neurostimulation on seizure control and their association with acute neurophysiological effects in rats
F Zhang, Y Yang, Y Xin, Y Sun, C Wang, J Zhu, T Tang, J Zhang, K Xu
Epilepsy & Behavior 143, 109212, 2023
32023
A 15-Ch. 0.019 mm2/Ch. 0.43% Gain Mismatch Orthogonal Code Chopping Instrumentation Amplifier SoC for Bio-Signal Acquisition
JH Park, T Tang, L Zhang, KA Ng, J Yoo
2019 IEEE Asian Solid-State Circuits Conference (A-SSCC), 295-296, 2019
32019
A generalized cortico-muscular-cortical network to evaluate the effects of three-week brain stimulation
J Liu, J Wang, G Tan, Y Sheng, L Feng, T Tang, X Li, Q Xie, H Liu, Y Wei
IEEE Transactions on Biomedical Engineering 71 (1), 195-206, 2023
22023
A TDM-based multi-channel analog front-end for wearable dry EEG recording system
T Tang, WL Goh, L Yao, Y Gao
2017 15th IEEE International New Circuits and Systems Conference (NEWCAS …, 2017
22017
A skin-mountable flexible biosensor based on Cu-MOF/PEDOT composites for sweat ascorbic acid monitoring
W Ling, X Shang, J Liu, T Tang
Biosensors and Bioelectronics 267, 116852, 2025
12025
The system can't perform the operation now. Try again later.