Simultaneous telemetric monitoring of brain glucose and lactate and motion in freely moving rats G Rocchitta, O Secchi, MD Alvau, D Farina, G Bazzu, G Calia, R Migheli, ... Analytical chemistry 85 (21), 10282-10288, 2013 | 93 | 2013 |
Simultaneous amperometric detection of ascorbic acid and antioxidant capacity in orange, blueberry and kiwi juice, by a telemetric system coupled with a fullerene-or nanotubes … A Barberis, Y Spissu, A Fadda, E Azara, G Bazzu, S Marceddu, A Angioni, ... Biosensors and Bioelectronics 67, 214-223, 2015 | 91 | 2015 |
Real-time monitoring of brain tissue oxygen using a miniaturized biotelemetric device implanted in freely moving rats G Bazzu, GGM Puggioni, S Dedola, G Calia, G Rocchitta, R Migheli, ... Analytical chemistry 81 (6), 2235-2241, 2009 | 75 | 2009 |
Biotelemetric monitoring of brain neurochemistry in conscious rats using microsensors and biosensors G Calia, G Rocchitta, R Migheli, G Puggioni, Y Spissu, G Bazzu, ... Sensors 9 (4), 2511-2523, 2009 | 63 | 2009 |
Design and construction of a low cost single-supply embedded telemetry system for amperometric biosensor applications PA Serra, G Rocchitta, G Bazzu, A Manca, GM Puggioni, JP Lowry, ... Sensors and Actuators B: Chemical 122 (1), 118-126, 2007 | 61 | 2007 |
Development and characterization of an ascorbate oxidase-based sensor–biosensor system for telemetric detection of AA and antioxidant capacity in fresh orange juice A Barberis, Y Spissu, G Bazzu, A Fadda, E Azara, D Sanna, M Schirra, ... Analytical chemistry 86 (17), 8727-8734, 2014 | 50 | 2014 |
Development and characterization of an implantable biosensor for telemetric monitoring of ethanol in the brain of freely moving rats G Rocchitta, O Secchi, MD Alvau, R Migheli, G Calia, G Bazzu, D Farina, ... Analytical chemistry 84 (16), 7072-7079, 2012 | 50 | 2012 |
α-Synuclein-and MPTP-Generated Rodent Models of Parkinson's Disease and the Study of Extracellular Striatal Dopamine Dynamics: A Microdialysis Approach G Bazzu, G Calia, G Puggioni, Y Spissu, G Rocchitta, P Debetto, ... CNS & Neurological Disorders-Drug Targets (Formerly Current Drug Targets-CNS …, 2010 | 49 | 2010 |
New ultralow-cost telemetric system for a rapid electrochemical detection of vitamin C in fresh orange juice A Barberis, G Bazzu, G Calia, GMG Puggioni, GG Rocchitta, R Migheli, ... Analytical Chemistry 82 (12), 5134-5140, 2010 | 45 | 2010 |
Real-time monitoring of glucose and phenols intestinal absorption through an integrated Caco-2TC7cells/biosensors telemetric device: Hypoglycemic effect of fruit phytochemicals A Barberis, A Garbetta, A Cardinali, G Bazzu, I D’Antuono, G Rocchitta, ... Biosensors and Bioelectronics 88, 159-166, 2017 | 34 | 2017 |
A 6-hydroxydopamine in vivo model of Parkinson’s disease G Mercanti, G Bazzu, P Giusti Neurotrophic Factors: Methods and Protocols, 355-364, 2012 | 31 | 2012 |
Detection of postharvest changes of ascorbic acid in fresh-cut melon, kiwi, and pineapple, by using a low cost telemetric system A Barberis, A Fadda, M Schirra, GF Bazzu, PA Serra Food chemistry 135 (3), 1555-1562, 2012 | 30 | 2012 |
Further In-vitro Characterization of an Implantable Biosensor for Ethanol Monitoring in the Brain O Secchi, M Zinellu, Y Spissu, M Pirisinu, G Bazzu, R Migheli, MS Desole, ... Sensors 13 (7), 9522-9535, 2013 | 26 | 2013 |
Novel integrated microdialysis–amperometric system for in vitro detection of dopamine secreted from PC12 cells: design, construction, and validation R Migheli, G Puggioni, S Dedola, G Rocchitta, G Calia, G Bazzu, ... Analytical biochemistry 380 (2), 323-330, 2008 | 26 | 2008 |
Low-temperature storage improves the over-time stability of implantable glucose and lactate biosensors G Puggioni, G Calia, P Arrigo, A Bacciu, G Bazzu, R Migheli, S Fancello, ... Sensors 19 (2), 422, 2019 | 22 | 2019 |
A novel method for the determination of ascorbic acid and antioxidant capacity in Opuntia ficus indica using in vivo microdialysis L Pretti, G Bazzu, PA Serra, G Nieddu Food chemistry 147, 131-137, 2014 | 21 | 2014 |
Propylene glycol stabilizes the linear response of glutamate biosensor: potential implications for in-vivo neurochemical monitoring G Rocchitta, A Bacciu, P Arrigo, R Migheli, G Bazzu, PA Serra Chemosensors 6 (4), 58, 2018 | 13 | 2018 |
Dual asymmetric-flow microdialysis for in vivo monitoring of brain neurochemicals G Bazzu, A Biosa, D Farina, Y Spissu, S Dedola, G Calia, G Puggioni, ... Talanta 85 (4), 1933-1940, 2011 | 13 | 2011 |
Effects of the neurotoxin MPTP and pargyline protection on extracellular energy metabolites and dopamine levels in the striatum of freely moving rats G Bazzu, G Rocchitta, R Migheli, MD Alvau, M Zinellu, G Puggioni, ... Brain research 1538, 159-171, 2013 | 12 | 2013 |
Do on-and off-pump coronary bypass surgery differently affect perioperative peripheral tissue metabolism? AP Cossu, S Suelzu, P Piu, M Orecchioni, G Bazzu, G Padua, ... Minerva anestesiologica 78 (1), 26-33, 2011 | 12 | 2011 |