Follow
SULAIMON SHODIYA
SULAIMON SHODIYA
Verified email at unimaid.edu.ng
Title
Cited by
Cited by
Year
Numerical and experimental study of an ejector as an expansion device in split-type air conditioner for energy savings
K Sumeru, S Sulaimon, H Nasution, FN Ani
Energy and Buildings 79, 98-105, 2014
502014
Numerical Study of an Ejector as an Expansion Device in Split-type Air Conditioners for Energy Savings
K Sumeru, S Sulaimon, FN Ani, H Nasution
Journal of Engineering and Technological Sciences 45 (2), 179-192, 2013
182013
Improved refrigerant characteristics flow predictions in adiabatic capillary tube
S Sulaimon, A Abdulaziz, AN Darus
Research Journal of Applied Sciences, Engineering and Technology 4 (13 …, 2012
112012
Taguchi method for development of mass flow rate correlation using hydrocarbon refrigerant mixture in capillary tube
S Sulaimon, H Nasution, AA Aziz, AH Abdul-Rahman, AN Darus
Journal of Engineering and Technological Sciences 46 (2), 141-151, 2014
62014
Investigation of Various Mixtures of HC290/HC600 Refrigerants in Adiabatic Capillary tube used in Split-type Air-conditioner
S Sulaimon, AA Aziz, N Henry, AN Darus
Applied Mechanics and Materials 388, 71-75, 2013
22013
Performance evaluation of a central air conditioning system using condensate as a discharge line cooler
K Sumeru, TP Pramudantoro, A Badarudin, A Setyawan, HA Sumeru, ...
Case Studies in Thermal Engineering 63, 105310, 2024
2024
Energy and Exergy Analysis of Chest Freezer Using R134a and R290 as Working Fluids Based on Experimental Data
TP Pramudantoro, R Muliawan, M Nuriyadi, S Hidayat, T Tohir, ...
International Journal Applied Technology Research 5 (2), 85-96, 2024
2024
Numerical Investigation of the Effect of Changes in Glass Typeon the Cooling Load in a Building
C Sunardi, WH Mitrakusuma, DT Pradita, S Kasni, S Sulaimon
International Journal Applied Technology Research 5 (1), 31-42, 2024
2024
EMPIRICAL CORRELATIONS FOR SIZING ADIABATIC CAPILLARY TUBES USING CONVENTIONAL REFRIGERANTS AND THEIR ALTERNATIVES
S Shodiya, AA Aziz, H Nasution, AN Darus
Heat Transfer Research 46 (5), 2015
2015
Empirical Correlations for Sizing Adiabatic Capillary Tube using LPG as Refrigerant in Split-Type Air-conditioner
S Sulaimon, AA Aziz, AN Darus, H Nasution
Applied Mechanics and Materials 493, 99-104, 2014
2014
Liquified Petroleum Gas as Refrigerant in Adiabatic Capillary Tube for Split-type Air-conditioner
S Sulaimon
Universiti Teknologi Malaysia, 2013
2013
Numerical Study of Split-type Air Conditio
K Sumeru, S Sulaim, S Sulaimon, FN Ani, H Nasution
2013
Neural Network-Based Prediction of Adiabatic Capillary Tube Characteristics With Alternative Refrigerant
AN Darus, S Sulaimon, AA Aziz, H Nasution
Jurnal Teknos-2k Vol 11 (2), 2011
2011
Empirical Correlation Of Refrigerant R-22 Mass Flow Rate Through Adiabatic Capillary Tube Using Statistical Experimental Design
S Sulaimon, AA Aziz, H Nasution, AN Darus
Jurnal Teknos-2k Vol 11 (2), 2011
2011
Experimental Study of Discharge Cooler Heat Exchanger Length Variation Using Condensate Drain on the Performance of Automotive Air Conditioner
K Sumeru, A Badarudin, I Wellid, LM Simbolon, S Sulaimon
Available at SSRN 4936357, 0
Experimental Investigation of Hydrocarbon Refrigerant as Alternative to HCFC22 in Adiabatic Capillary Tube using Statistical Experimental Design
S Sulaimon, A Abdulaziz, N Henry, AN Darus
The system can't perform the operation now. Try again later.
Articles 1–16