Follow
Alexey Shvarev
Alexey Shvarev
R&D Head, Engineering Center Technohim JSC
Verified email at technohim.com
Title
Cited by
Cited by
Year
Reversible electrochemical detection of nonelectroactive polyions
A Shvarev, E Bakker
Journal of the American Chemical Society 125 (37), 11192-11193, 2003
1772003
Pulsed galvanostatic control of ionophore-based polymeric ion sensors
A Shvarev, E Bakker
Analytical chemistry 75 (17), 4541-4550, 2003
1302003
Pulstrodes: triple pulse control of potentiometric sensors
S Makarychev-Mikhailov, A Shvarev, E Bakker
Journal of the American Chemical Society 126 (34), 10548-10549, 2004
992004
Response characteristics of a reversible electrochemical sensor for the polyion protamine
A Shvarev, E Bakker
Analytical chemistry 77 (16), 5221-5228, 2005
862005
Calcium pulstrodes with 10-fold enhanced sensitivity for measurements in the physiological concentration range
S Makarychev-Mikhailov, A Shvarev, E Bakker
Analytical chemistry 78 (8), 2744-2751, 2006
602006
Selective coulometric release of ions from ion selective polymeric membranes for calibration-free titrations
V Bhakthavatsalam, A Shvarev, E Bakker
Analyst 131 (8), 895-900, 2006
512006
Coulometric sodium chloride removal system with nafion membrane for seawater sample treatment
E Grygolowicz-Pawlak, M Sohail, M Pawlak, B Neel, A Shvarev, ...
Analytical chemistry 84 (14), 6158-6165, 2012
482012
Selectivity enhancement of anion-responsive electrodes by pulsed chronopotentiometry
KL Gemene, A Shvarev, E Bakker
Analytica chimica acta 583 (1), 190-196, 2007
422007
Potassium-selective conductometric sensor
AE Shvarev, DA Rantsan, KN Mikhelson
Sensors and Actuators B: Chemical 76 (1-3), 500-505, 2001
372001
Fabrication of micrometer and submicrometer-sized ion-selective optodes via a solvent displacement process
V Bychkova, A Shvarev
Analytical chemistry 81 (6), 2325-2331, 2009
352009
Distinguishing free and total calcium with a single pulsed galvanostatic ion-selective electrode
A Shvarev, E Bakker
Talanta 63 (1), 195-200, 2004
352004
Drop-and-catch (DnC) calorimetry using aerodynamic levitation and laser heating
DKAN Sergey V. Ushakov, Alexey Shvarev, Timur Alexeev
Journal of the American Ceramic Society 100 (2), 754–760, 2016
33*2016
Detection limits of thin layer coulometry with ionophore based ion-selective membranes
A Shvarev, B Neel, E Bakker
Analytical chemistry 84 (18), 8038-8044, 2012
312012
Photoresponsive ion-selective optical sensor
A Shvarev
Journal of the American Chemical Society 128 (22), 7138-7139, 2006
302006
Solid-contact electrochemical polyion sensors for monitoring peptidase activities
K Fordyce, A Shvarev
Analytical chemistry 80 (3), 827-833, 2008
292008
Pulsed galvanostatic control of solid-state polymeric ion-selective electrodes
H Perera, K Fordyce, A Shvarev
Analytical chemistry 79 (12), 4564-4573, 2007
292007
New trends in ion-selective electrodes
S Makarychev-Mikhailov, A Shvarev, E Bakker
Electrochemical Sensors, Biosensors and their Biomedical Applications, 71-114, 2008
282008
Enzyme logic gate associated with a single responsive microparticle: scaling biocomputing to microsize systems
V Bychkova, A Shvarev, J Zhou, M Pita, E Katz
Chemical communications 46 (1), 94-96, 2010
192010
Kinetic modulation of pulsed chronopotentiometric polymeric membrane ion sensors by polyelectrolyte multilayers
Y Xu, C Xu, A Shvarev, T Becker, R De Marco, E Bakker
Analytical chemistry 79 (18), 7154-7160, 2007
192007
Composite regenerable adsorption carbon material and its regeneration method
AE Shvarev, AV Pimenov, AG Mitilineos, JL Shmidt
US Patent 6,391,185, 2002
172002
The system can't perform the operation now. Try again later.
Articles 1–20