The simulation of annual daylight illuminance distributions—a state-of-the-art comparison of six RADIANCE-based methods CF Reinhart, S Herkel Energy and buildings 32 (2), 167-187, 2000 | 440 | 2000 |
Towards a model of user behaviour regarding the manual control of windows in office buildings S Herkel, U Knapp, J Pfafferott Building and environment 43 (4), 588-600, 2008 | 391 | 2008 |
GIS-based planning and modeling for renewable energy: Challenges and future research avenues B Resch, G Sagl, T Törnros, A Bachmaier, JB Eggers, S Herkel, ... ISPRS International Journal of Geo-Information 3 (2), 662-692, 2014 | 204 | 2014 |
Load shifting using the heating and cooling system of an office building: Quantitative potential evaluation for different flexibility and storage options K Klein, S Herkel, HM Henning, C Felsmann Applied Energy 203, 917-937, 2017 | 169 | 2017 |
Design, monitoring and evaluation of a low energy office building with passive cooling by night ventilation J Pfafferott, S Herkel, M Wambsganß Energy and buildings 36 (5), 455-465, 2004 | 160 | 2004 |
Energietechnologien 2050-Schwerpunkte für Forschung und Entwicklung M Arens, C Dötsch, S Herkel, W Krewitt, P Markewitz, D Möst, M Scheufen Fraunhofer-Verlag, 2010 | 158 | 2010 |
Primary energy and comfort performance of ventilation assisted thermo-active building systems in continental climates GP Henze, C Felsmann, DE Kalz, S Herkel Energy and Buildings 40 (2), 99-111, 2008 | 158 | 2008 |
Comparison of low-energy office buildings in summer using different thermal comfort criteria JÜ Pfafferott, S Herkel, DE Kalz, A Zeuschner Energy and Buildings 39 (7), 750-757, 2007 | 156 | 2007 |
Design of passive cooling by night ventilation: evaluation of a parametric model and building simulation with measurements J Pfafferott, S Herkel, M Jäschke Energy and Buildings 35 (11), 1129-1143, 2003 | 148 | 2003 |
Energy efficient office buildings with passive cooling–Results and experiences from a research and demonstration programme K Voss, S Herkel, J Pfafferott, G Löhnert, A Wagner Solar Energy 81 (3), 424-434, 2007 | 91 | 2007 |
Impact of adaptive comfort criteria and heat waves on optimal building thermal mass control GP Henze, J Pfafferott, S Herkel, C Felsmann Energy and Buildings 39 (2), 221-235, 2007 | 87 | 2007 |
Systematic classification of combined solar thermal and heat pump systems E Frank, M Haller, S Herkel, J Ruschenburg Proc. of the EuroSun 2010 Conference, Graz, Austria, 2010 | 78 | 2010 |
Climate based simulation of different shading device systems for comfort and energy demand J Wienold, F Frontini, S Herkel, S Mende | 77 | 2011 |
Optimizing energy efficiency and occupant comfort with climate specific design of the building C Mitterer, HM Künzel, S Herkel, A Holm Frontiers of Architectural Research 1 (3), 229-235, 2012 | 71 | 2012 |
Performance of air and ground source heat pumps retrofitted to radiator heating systems and measures to reduce space heating temperatures in existing buildings M Lämmle, C Bongs, J Wapler, D Günther, S Hess, M Kropp, S Herkel Energy 242, 122952, 2022 | 67 | 2022 |
A preliminary model of user behaviour regarding the manual control of windows in office buildings S Herkel, U Knapp, J Pfafferott Building Simulation, 2005 | 67 | 2005 |
Solar control: A general method for modelling of solar gains through complex facades in building simulation programs TE Kuhn, S Herkel, F Frontini, P Strachan, G Kokogiannakis Energy and Buildings 43 (1), 19-27, 2011 | 66 | 2011 |
Bürogebäude mit Zukunft, m. CD-ROM: Konzepte, Analysen, Erfahrungen. K Voss, G Löhnert, S Herkel, A Wagner Fraunhofer IRB Verlag, 2010 | 65 | 2010 |
Statistical simulation of user behaviour in low-energy office buildings J Pfafferott, S Herkel Solar Energy 81 (5), 676-682, 2007 | 64 | 2007 |
A statistical analysis on market-available solar thermal heat pump systems J Ruschenburg, S Herkel, HM Henning Solar Energy 95, 79-89, 2013 | 62 | 2013 |