Concurrent assessment of gait kinematics using marker-based and markerless motion capture RM Kanko, EK Laende, EM Davis, WS Selbie, KJ Deluzio Journal of biomechanics 127, 110665, 2021 | 233 | 2021 |
Inter-session repeatability of markerless motion capture gait kinematics RM Kanko, E Laende, WS Selbie, KJ Deluzio Journal of Biomechanics 121, 110422, 2021 | 132 | 2021 |
Assessment of spatiotemporal gait parameters using a deep learning algorithm-based markerless motion capture system RM Kanko, EK Laende, G Strutzenberger, M Brown, WS Selbie, V DePaul, ... Journal of Biomechanics 122, 110414, 2021 | 131 | 2021 |
A randomized controlled trial of tibial component migration with kinematic alignment using patient-specific instrumentation versus mechanical alignment using computer-assisted … EK Laende, CG Richardson, MJ Dunbar The bone & joint journal 101 (8), 929-940, 2019 | 113 | 2019 |
Clothing condition does not affect meaningful clinical interpretation in markerless motion capture VT Keller, JB Outerleys, RM Kanko, EK Laende, KJ Deluzio Journal of Biomechanics 141, 111182, 2022 | 54 | 2022 |
Equivalent 2-year stabilization of uncemented tibial component migration despite higher early migration compared with cemented fixation: an RSA study on 360 total knee … EK Laende, JL Astephen Wilson, J Mills Flemming, ER Valstar, ... Acta orthopaedica 90 (2), 172-178, 2019 | 43 | 2019 |
Predictive value of short-term migration in determining long-term stable fixation in cemented and cementless total knee arthroplasties EK Laende, CG Richardson, MJ Dunbar The Bone & Joint Journal 101 (7_Supple_C), 55-60, 2019 | 42 | 2019 |
The assessment of the stability of the tibial component of a novel knee arthroplasty system using radiostereometric analysis TR Turgeon, TC Gascoyne, EK Laende, MJ Dunbar, ER Bohm, ... The Bone & Joint Journal 100 (12), 1579-1584, 2018 | 28 | 2018 |
Implementation and validation of an implant-based coordinate system for RSA migration calculation EK Laende, KJ Deluzio, AW Hennigar, MJ Dunbar Journal of biomechanics 42 (14), 2387-2393, 2009 | 25 | 2009 |
Migration and wear of a dual mobility acetabular construct at 3 years measured by radiostereometric analysis EK Laende, CG Richardson, MJ Dunbar The Journal of Arthroplasty 35 (4), 1109-1116, 2020 | 16 | 2020 |
In vivo wear measurement in a modern total knee arthroplasty with model-based radiostereometric analysis T Gascoyne, S Parashin, M Teeter, E Bohm, E Laende, M Dunbar, ... The Bone & Joint Journal 101 (11), 1348-1355, 2019 | 15 | 2019 |
Early identification of patient satisfaction two years after total knee arthroplasty KL Young-Shand, MJ Dunbar, EK Laende, JEM Flemming, JLA Wilson The Journal of Arthroplasty 36 (7), 2473-2479, 2021 | 14 | 2021 |
Stable migration of peri-apatite-coated uncemented tibial components in a multicentre study MJ Dunbar, EK Laende, D Collopy, CG Richardson The bone & joint journal 99 (12), 1596-1602, 2017 | 12 | 2017 |
Comparison of concurrent and asynchronous running kinematics and kinetics from marker-based and markerless motion capture under varying clothing conditions RM Kanko, JB Outerleys, EK Laende, WS Selbie, KJ Deluzio Journal of Applied Biomechanics 1 (aop), 1-9, 2024 | 11 | 2024 |
Guideline for RSA and CT-RSA implant migration measurements: an update of standardizations and recommendations BL Kaptein, B Pijls, L Koster, J Kärrholm, H Maury, A Niesen, ... Acta Orthopaedica 95, 256, 2024 | 10 | 2024 |
Markerless motion capture provides repeatable gait outcomes in patients with knee osteoarthritis J Outerleys, A Mihic, V Keller, E Laende, K Deluzio Journal of Biomechanics 168, 112115, 2024 | 8 | 2024 |
6-month migration sufficient for evaluation of total knee replacements: a systematic review and meta-analysis R Puijk, RH Puijk, EK Laende, MJ Dunbar, JWM Plevier, PA Nolte, ... Acta Orthopaedica 94, 577, 2023 | 8 | 2023 |
Tibial component migration after total knee arthroplasty with high-viscosity bone cement EK Laende, CG Richardson, AR Meldrum, MJ Dunbar The Journal of Arthroplasty 36 (6), 2000-2005, 2021 | 7 | 2021 |
Inter-session repeatability of Theia3D markerless motion capture gait kinematics R Kanko, E Laende, S Selbie, K Deluzio bioRxiv, 2020.06. 23.155358, 2020 | 7 | 2020 |
Principal component analysis of whole-body kinematics using markerless motion capture during static balance tasks KJ Eveleigh, KJ Deluzio, SH Scott, EK Laende Journal of biomechanics 152, 111556, 2023 | 6 | 2023 |