Self-calibration of cone-beam CT geometry using 3D–2D image registration S Ouadah, JW Stayman, GJ Gang, T Ehtiati, JH Siewerdsen Physics in Medicine & Biology 61 (7), 2613, 2016 | 93 | 2016 |
Correction of patient motion in cone-beam CT using 3D–2D registration S Ouadah, M Jacobson, JW Stayman, T Ehtiati, C Weiss, JH Siewerdsen Physics in Medicine & Biology 62 (23), 8813, 2017 | 49 | 2017 |
Task-driven image acquisition and reconstruction in cone-beam CT GJ Gang, JW Stayman, T Ehtiati, JH Siewerdsen Physics in Medicine & Biology 60 (8), 3129, 2015 | 46 | 2015 |
System and method for unsupervised detection and gleason grading of prostate cancer whole mounts using NIR fluorscence A Khamene, T Ehtiati, JV Frangioni, V Kianzad, FS Azar US Patent 8,139,831, 2012 | 39 | 2012 |
Task-driven source–detector trajectories in cone-beam computed tomography: II. Application to neuroradiology S Capostagno, JW Stayman, M Jacobson, T Ehtiati, CR Weiss, ... Journal of Medical Imaging 6 (2), 025004-025004, 2019 | 30 | 2019 |
System and method for the generation of attenuation correction maps from MR images C Lenglet, C Chefd'hotel, B Geiger, T Ehtiati, J Gühring US Patent 8,218,848, 2012 | 28 | 2012 |
Task-driven orbit design and implementation on a robotic C-arm system for cone-beam CT S Ouadah, M Jacobson, JW Stayman, T Ehtiati, C Weiss, JH Siewerdsen Proceedings of SPIE--the International Society for Optical Engineering 10132 …, 2017 | 27 | 2017 |
Deformable motion compensation for interventional cone-beam CT S Capostagno, A Sisniega, JW Stayman, T Ehtiati, CR Weiss, ... Physics in Medicine & Biology 66 (5), 055010, 2021 | 26 | 2021 |
Diagnostic quality and accuracy of low dose 3D-DSA protocols in the evaluation of intracranial aneurysms MS Pearl, C Torok, Z Katz, SA Messina, J Blasco, RJ Tamargo, J Huang, ... Journal of neurointerventional surgery 7 (5), 386-390, 2015 | 26 | 2015 |
A novel method of 3D image analysis of high-resolution cone beam CT and multi slice CT for the detection of semicircular canal dehiscence K Eibenberger, J Carey, T Ehtiati, C Trevino, J Dolberg, T Haslwanter Otology & Neurotology 35 (2), 329-337, 2014 | 26 | 2014 |
Planning evaluation of C-arm cone beam CT angiography for target delineation in stereotactic radiation surgery of brain arteriovenous malformations J Kang, J Huang, P Gailloud, D Rigamonti, M Lim, V Bernard, T Ehtiati, ... International Journal of Radiation Oncology* Biology* Physics 90 (2), 430-437, 2014 | 20 | 2014 |
Fused X-ray and MR imaging guidance of intrapericardial delivery of microencapsulated human mesenchymal stem cells in immunocompetent swine Y Fu, N Azene, T Ehtiati, A Flammang, WD Gilson, K Gabrielson, ... Radiology 272 (2), 427-437, 2014 | 19 | 2014 |
Reference-free learning-based similarity metric for motion compensation in cone-beam CT H Huang, JH Siewerdsen, W Zbijewski, CR Weiss, M Unberath, T Ehtiati, ... Physics in Medicine & Biology 67 (12), 125020, 2022 | 18 | 2022 |
Aortic arch injection with C-arm cone beam CT for radiosurgery treatment planning of cerebral arteriovenous malformations MG Radvany, T Ehtiati, J Huang, M Mahesh, P Gailloud Journal of neurointerventional surgery 4 (5), e28-e28, 2012 | 17 | 2012 |
Using C-arm X-ray imaging to guide local reporter probe delivery for tracking stem cell engraftment DA Kedziorek, M Solaiyappan, P Walczak, T Ehtiati, Y Fu, JWM Bulte, ... Theranostics 3 (11), 916, 2013 | 15 | 2013 |
Self-calibration of cone-beam CT geometry using 3D-2D image registration: Development and application to tasked-based imaging with a robotic C-arm S Ouadah, JW Stayman, G Gang, A Uneri, T Ehtiati, JH Siewerdsen Medical Imaging 2015: Image-Guided Procedures, Robotic Interventions, and …, 2015 | 14 | 2015 |
Multifractal characterization of the electromyogram signals in presence of fatigue T Ehtiati, W Kinsner, ZK Moussavi Conference Proceedings. IEEE Canadian Conference on Electrical and Computer …, 1998 | 14 | 1998 |
Reducing radiation dose while maintaining diagnostic image quality of cerebral three-dimensional digital subtraction angiography: an in vivo study in swine MS Pearl, CM Torok, SA Messina, M Radvany, SN Rao, T Ehtiati, ... Journal of neurointerventional surgery 6 (9), 672-676, 2014 | 13 | 2014 |
Extended intraoperative longitudinal 3-dimensional cone beam computed tomography imaging with a continuous multi-turn reverse helical scan T Reynolds, YQ Ma, AJ Kanawati, A Constantinidis, Z Williams, G Gang, ... Investigative radiology 57 (11), 764-772, 2022 | 12 | 2022 |
Multifractal characterization of electromyogram signals T Ehtiati, W Kinsner Engineering Solutions for the Next Millennium. 1999 IEEE Canadian Conference …, 1999 | 11 | 1999 |