STIR: software for tomographic image reconstruction release 2 K Thielemans, C Tsoumpas, S Mustafovic, T Beisel, P Aguiar, N Dikaios, ... Physics in Medicine & Biology 57 (4), 867, 2012 | 605 | 2012 |
An expanded theoretical treatment of iteration-dependent majorize-minimize algorithms MW Jacobson, JA Fessler IEEE Transactions on Image Processing 16 (10), 2411-2422, 2007 | 167 | 2007 |
Joint estimation of image and deformation parameters in motion-corrected PET MW Jacobson, JA Fessler 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No …, 2003 | 119 | 2003 |
Enhanced 3D PET OSEM reconstruction using inter-update Metz filtering M Jacobson, R Levkovitz, A Ben-Tal, K Thielemans, T Spinks, D Belluzzo, ... Physics in Medicine & Biology 45 (8), 2417, 2000 | 79 | 2000 |
Correction of patient motion in cone-beam CT using 3D–2D registration S Ouadah, M Jacobson, JW Stayman, T Ehtiati, C Weiss, JH Siewerdsen Physics in Medicine & Biology 62 (23), 8813, 2017 | 49 | 2017 |
Penalized-likelihood reconstruction with high-fidelity measurement models for high-resolution cone-beam imaging S Tilley, M Jacobson, Q Cao, M Brehler, A Sisniega, W Zbijewski, ... IEEE transactions on medical imaging 37 (4), 988-999, 2017 | 48 | 2017 |
Intraoperative evaluation of device placement in spine surgery using known-component 3D–2D image registration A Uneri, T De Silva, J Goerres, MW Jacobson, MD Ketcha, ... Physics in Medicine & Biology 62 (8), 3330, 2017 | 47 | 2017 |
Multi-stage 3D–2D registration for correction of anatomical deformation in image-guided spine surgery MD Ketcha, T De Silva, A Uneri, MW Jacobson, J Goerres, G Kleinszig, ... Physics in Medicine & Biology 62 (11), 4604, 2017 | 44 | 2017 |
Spinal pedicle screw planning using deformable atlas registration J Goerres, A Uneri, T De Silva, M Ketcha, S Reaungamornrat, ... Physics in Medicine & Biology 62 (7), 2871, 2017 | 44 | 2017 |
Mobile C‐Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone‐Beam CT imaging performance NM Sheth, W Zbijewski, MW Jacobson, G Abiola, G Kleinszig, S Vogt, ... Medical physics 45 (12), 5420-5436, 2018 | 33 | 2018 |
Motion correction for CT using marker projections JW Stayman, M Jacobson US Patent 8,055,049, 2011 | 32 | 2011 |
Joint estimation of respiratory motion and activity in 4D PET using CT side information MW Jacobson, JA Fessier 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006 …, 2006 | 32 | 2006 |
Nucleation and growth during the chemical vapor deposition of diamond on SiO2 substrates J Rankin, RE Boekenhauer, R Csencsits, Y Shigesato, MW Jacobson, ... Journal of materials research 9 (8), 2164-2173, 1994 | 32 | 1994 |
Task-driven source–detector trajectories in cone-beam computed tomography: II. Application to neuroradiology S Capostagno, JW Stayman, M Jacobson, T Ehtiati, CR Weiss, ... Journal of Medical Imaging 6 (2), 025004-025004, 2019 | 31 | 2019 |
Registration of MRI to intraoperative radiographs for target localization in spinal interventions T De Silva, A Uneri, MD Ketcha, S Reaungamornrat, J Goerres, ... Physics in Medicine & Biology 62 (2), 684, 2017 | 31 | 2017 |
C-arm positioning using virtual fluoroscopy for image-guided surgery T De Silva, J Punnoose, A Uneri, J Goerres, M Jacobson, MD Ketcha, ... Medical imaging 2017: image-guided procedures, robotic interventions, and …, 2017 | 28 | 2017 |
Deformable 3D-2D registration of known components for image guidance in spine surgery A Uneri, J Goerres, T De Silva, MW Jacobson, MD Ketcha, ... Medical Image Computing and Computer-Assisted Intervention-MICCAI 2016: 19th …, 2016 | 28 | 2016 |
Planning, guidance, and quality assurance of pelvic screw placement using deformable image registration J Goerres, A Uneri, M Jacobson, B Ramsay, T De Silva, M Ketcha, R Han, ... Physics in Medicine & Biology 62 (23), 9018, 2017 | 27 | 2017 |
Task-driven orbit design and implementation on a robotic C-arm system for cone-beam CT S Ouadah, M Jacobson, JW Stayman, T Ehtiati, C Weiss, JH Siewerdsen Proceedings of SPIE--the International Society for Optical Engineering 10132, 2017 | 27 | 2017 |
Virtual fluoroscopy for intraoperative C-arm positioning and radiation dose reduction T De Silva, J Punnoose, A Uneri, M Mahesh, J Goerres, M Jacobson, ... Journal of Medical Imaging 5 (1), 015005-015005, 2018 | 24 | 2018 |