अनुसरण करें
Dionysios Bournas
Dionysios Bournas
Senior Researcher, European Laboratory for Structural Assessment, Safety and Security of Buildings
ec.europa.eu पर सत्यापित ईमेल - मुख्यपृष्ठ
टाइटल
इन्होंने कहा
इन्होंने कहा
वर्ष
Strengthening of concrete structures with textile reinforced mortars: State-of-the-art review
LN Koutas, Z Tetta, DA Bournas, TC Triantafillou
Journal of Composites for Construction 23 (1), 03118001, 2019
4762019
Textile-reinforced mortar versus fiber-reinforced polymer confinement in reinforced concrete columns
DA Bournas, PV Lontou, CG Papanicolaou, TC Triantafillou
ACI Structural Journal 104 (6), 740, 2007
4052007
Textile-reinforced mortar (TRM) versus fiber-reinforced polymers (FRP) in shear strengthening of concrete beams
ZC Tetta, LN Koutas, DA Bournas
Composites Part B: Engineering 77, 338-348, 2015
3252015
Textile-reinforced mortar (TRM) versus fibre-reinforced polymers (FRP) in flexural strengthening of RC beams
SM Raoof, LN Koutas, DA Bournas
Construction and Building Materials 151, 279-291, 2017
2632017
Performance of industrial buildings during the Emilia earthquakes in Northern Italy and recommendations for their strengthening
DA Bournas, P Negro, FF Taucer
Bulletin of Earthquake Engineering 12, 2383-2404, 2014
2632014
TRM vs FRP jacketing in shear strengthening of concrete members subjected to high temperatures
ZC Tetta, DA Bournas
Composites Part B: Engineering 106, 190-205, 2016
1972016
Textile-reinforced mortar versus FRP jacketing in seismic retrofitting of RC columns with continuous or lap-spliced deformed bars
DA Bournas, TC Triantafillou, K Zygouris, F Stavropoulos
Journal of Composites for Construction 13 (5), 360-371, 2009
1832009
Energy performance of existing residential buildings in Europe: A novel approach combining energy with seismic retrofitting
DA Pohoryles, C Maduta, DA Bournas, LA Kouris
Energy and buildings 223, 110024, 2020
1742020
TRM versus FRP in flexural strengthening of RC beams: Behaviour at high temperatures
SM Raoof, DA Bournas
Construction and building materials 154, 424-437, 2017
1732017
Bond between textile-reinforced mortar (TRM) and concrete substrates: Experimental investigation
SM Raoof, LN Koutas, DA Bournas
Composites Part B: Engineering 98, 350-361, 2016
1732016
Bond between TRM versus FRP composites and concrete at high temperatures
SM Raoof, DA Bournas
Composites Part B: Engineering 127, 150-165, 2017
1722017
Flexural strengthening of RC columns with NSM FRP or stainless steel
DA Bournas, TC Triantafillou
Aci Struct. J 106 (4), 495-505, 2009
1622009
Concurrent seismic and energy retrofitting of RC and masonry building envelopes using inorganic textile-based composites combined with insulation materials: A new concept
DA Bournas
Composites Part B: Engineering 148, 166-179, 2018
1542018
Shear strengthening of full-scale RC T-beams using textile-reinforced mortar and textile-based anchors
ZC Tetta, LN Koutas, DA Bournas
Composites Part B: Engineering 95, 225-239, 2016
1512016
Pseudodynamic tests on a full-scale 3-storey precast concrete building: Behavior of the mechanical connections and floor diaphragms
DA Bournas, P Negro, FJ Molina
Engineering structures 57, 609-627, 2013
1472013
Experimental assessment of the seismic performance of a prefabricated concrete structural wall system
A Pavese, DA Bournas
Engineering Structures 33 (6), 2049-2062, 2011
1342011
Seismic upgrading of existing reinforced concrete buildings: A state-of-the-art review
PD Gkournelos, TC Triantafillou, DA Bournas
Engineering Structures 240, 112273, 2021
1322021
Pseudodynamic tests on a full-scale 3-storey precast concrete building: Global response
P Negro, DA Bournas, FJ Molina
Engineering structures 57, 594-608, 2013
1282013
Out-of-plane response of masonry walls strengthened using textile-mortar system
FA Kariou, SP Triantafyllou, DA Bournas, LN Koutas
Construction and Building Materials 165, 769-781, 2018
1242018
Flexural strengthening of two-way RC slabs with textile-reinforced mortar: experimental investigation and design equations
LN Koutas, DA Bournas
Journal of Composites for Construction 21 (1), 04016065, 2017
1222017
सिस्टम अभी संचालन निष्पादित नहीं कर सकता. बाद में फिर से प्रयास करें.
लेख 1–20