Prati
Narvada Jugnee
Narvada Jugnee
Senior Diabetes Research Specialist, Imperial College London
Potvrđena adresa e-pošte na imperial.ac.uk
Naslov
Citirano
Citirano
Godina
Cardiovascular and metabolic effects of metformin in patients with type 1 diabetes (REMOVAL): a double-blind, randomised, placebo-controlled trial
JR Petrie, N Chaturvedi, I Ford, MCGJ Brouwers, N Greenlaw, T Tillin, ...
The lancet Diabetes & endocrinology 5 (8), 597-609, 2017
3632017
A randomized controlled pilot study of continuous glucose monitoring and flash glucose monitoring in people with type 1 diabetes and impaired awareness of hypoglycaemia
M Reddy, N Jugnee, A El Laboudi, E Spanudakis, S Anantharaja, N Oliver
Diabetic Medicine 35 (4), 483-490, 2018
2962018
A pilot study in humans of microneedle sensor arrays for continuous glucose monitoring
S Sharma, A El-Laboudi, M Reddy, N Jugnee, S Sivasubramaniyam, ...
Analytical Methods 10 (18), 2088-2095, 2018
1242018
Switching from flash glucose monitoring to continuous glucose monitoring on hypoglycemia in adults with type 1 diabetes at high hypoglycemia risk: the extension phase of the I …
M Reddy, N Jugnee, S Anantharaja, N Oliver
Diabetes technology & therapeutics 20 (11), 751-757, 2018
1092018
Metabolic control with the bio-inspired artificial pancreas in adults with type 1 diabetes: a 24-hour randomized controlled crossover study
M Reddy, P Herrero, ME Sharkawy, P Pesl, N Jugnee, D Pavitt, ...
Journal of diabetes science and technology 10 (2), 405-413, 2016
542016
Feasibility study of a bio-inspired artificial pancreas in adults with type 1 diabetes
M Reddy, P Herrero, M El Sharkawy, P Pesl, N Jugnee, H Thomson, ...
Diabetes technology & therapeutics 16 (9), 550-557, 2014
452014
Glycemic variability and hypoglycemic excursions with continuous glucose monitoring compared to intermittently scanned continuous glucose monitoring in adults with highest risk …
P Avari, V Moscardo, N Jugnee, N Oliver, M Reddy
Journal of diabetes science and technology 14 (3), 567-574, 2020
292020
Safety and feasibility of the PEPPER adaptive bolus advisor and safety system: a randomized control study
P Avari, Y Leal, P Herrero, M Wos, N Jugnee, M Arnoriaga-Rodríguez, ...
Diabetes Technology & Therapeutics 23 (3), 175-186, 2021
232021
The accuracy of continuous glucose sensors in people with diabetes undergoing hemodialysis (ALPHA Study)
P Avari, W Tang, N Jugnee, I Hersi, A Al-Balah, T Tan, AH Frankel, ...
Diabetes Technology & Therapeutics 25 (7), 447-456, 2023
182023
The bio-inspired artificial pancreas for type 1 diabetes control in the home: system architecture and preliminary results
P Herrero, M El-Sharkawy, J Daniels, N Jugnee, CN Uduku, M Reddy, ...
Journal of diabetes science and technology 13 (6), 1017-1025, 2019
112019
Safety and efficacy of an adaptive bolus calculator for type 1 diabetes: a randomized controlled crossover study
R Unsworth, R Armiger, N Jugnee, M Thomas, P Herrero, P Georgiou, ...
Diabetes Technology & Therapeutics 25 (6), 414-425, 2023
82023
Real‐time continuous glucose monitoring immediately after severe hypoglycaemia requiring emergency medical services: a randomised controlled trial
C Uduku, V Pendolino, N Jugnee, N Oliver, R Fothergill, M Reddy
Diabetic Medicine 40 (7), e15100, 2023
32023
Does the addition of glucagon to a closed loop system impact on post exercise glycaemia?
S Seechurn, M Reddy, N Jugnee, M El Sharkawy, P Hesl, ...
DIABETES TECHNOLOGY & THERAPEUTICS 18, A60-A61, 2016
32016
Does the addition of glucagon to the closed loop insulin pump add any benefit
S Seechurn, M Reddy, N Jugnee, M El Sharkawy, P Pesl, P Herrero, ...
Diabetes Technol Ther 18 (S1), A149, 2016
32016
Acceptability of a Patient and Clinical Platform of an Advanced Bolus Calculator for Type 1 Diabetes (ABC4D)
P Pesl, P Herrero, M Reddy, M Xenou, N Jugnee, N Oliver, D Johnston, ...
DIABETES TECHNOLOGY & THERAPEUTICS 17, A130-A130, 2015
32015
Trust and contextual engagement with the PEPPER system: The qualitative findings of a clinical feasibility study
MWA Aldea, P Avari, YLCMD Duce, M Fernández-Balsells, ...
22020
Ambulatory glucose profiling and glycaemic outcomes when switching flash to continuous glucose monitoring: the i-hart cgm study
P Avari, V Moscardo, N Jugnee, M Reddy, N Oliver
Diabetes technology & therapeutics 21, A108-A109, 2019
22019
The impact of switching from flash glucose monitoring to real-time CGM on hypoglycaemia in adults with type 1 diabetes and impaired awareness of hypoglycaemia
M Reddy, N Jugnee, S Anantharaja, N Oliver
Diabetes technology & therapeutics 20, A25-A25, 2018
22018
Impact on hypoglycaemia awareness of real time continuous glucose monitoring and intermittent continuous glucose data (I HART CGM)
M Reddy, N Jugnee, E Spanudakis, N Oliver
Diabetic medicine 34, 29-29, 2017
22017
Clinical Safety Evaluation of an Advanced Bolus Calculator for Type 1 Diabetes (ABC4D)
M Reddy, P Pesl, M Xenou, N Jugnee, C Toumazou, D Johnston, ...
Diabetes Technology and Therapeutics 17, A130-A131, 2015
22015
Sustav trenutno ne može provesti ovu radnju. Pokušajte ponovo kasnije.
Članci 1–20