Microstructure and compression properties of 3D powder printed Ti-6Al-4V scaffolds with designed porosity: Experimental and computational analysis S Barui, S Chatterjee, S Mandal, A Kumar, B Basu Materials Science and Engineering: C 70, 812-823, 2017 | 139 | 2017 |
Optimal selection of dental implant for different bone conditions based on the mechanical response S Roy, M Das, P Chakraborty, JK Biswas, S Chatterjee, N Khutia, S Saha, ... Acta of bioengineering and biomechanics 19 (2), 2017 | 47 | 2017 |
Biomechanical analysis to probe role of bone condition and subject weight in stiffness customization of femoral stem for improved periprosthetic biomechanical response S Chatterjee, S Roy, S Majumder, A RoyChowdhury Journal of Biomechanical Engineering 142 (10), 101002, 2020 | 31 | 2020 |
Finite element analysis to probe the influence of acetabular shell design, liner material, and subject parameters on biomechanical response in periprosthetic bone S Chatterjee, S Kobylinski, B Basu Journal of biomechanical engineering 140 (10), 101014, 2018 | 29 | 2018 |
Periprosthetic biomechanical response towards dental implants, with functional gradation, for single/multiple dental loss S Chatterjee, S Sarkar, SR Kalidindi, B Basu Journal of the mechanical behavior of biomedical materials 94, 249-258, 2019 | 22 | 2019 |
Effect of single and multilevel artificial inter-vertebral disc replacement in lumbar spine: a finite element study JK Biswas, M Rana, A Malas, S Roy, S Chatterjee, S Choudhury The International Journal of Artificial Organs 45 (2), 193-199, 2022 | 21 | 2022 |
Computational intelligence based design of implant for varying bone conditions S Chatterjee, S Dey, S Majumder, A RoyChowdhury, S Datta International Journal for Numerical Methods in Biomedical Engineering 35 (6 …, 2019 | 19 | 2019 |
Problems with use of trans-tibial prosthesis S Chatterjee, S Majumder, A RoyChowdhury, S Pal Journal of Medical Imaging and Health Informatics 6 (2), 269-284, 2016 | 18 | 2016 |
Customization of design for hip implants S Chatterjee, UB Ghosh, S Majumder, A RoyChowdhury, S Pal Indian Journal of Biomechanics 4 (1), 58-62, 2013 | 5 | 2013 |
Dosimetry of pulsed magnetic field towards attaining bacteriostatic effect on Enterococcus faecalis: Implications for endodontic therapy S Naskar, Chandan, D Baskaran, AN Roy Choudhury, S Chatterjee, ... International Endodontic Journal 54 (10), 1878-1891, 2021 | 4 | 2021 |
Finite Element Analysis in Biomechanics S Chatterjee Advances in Computational Approaches in Biomechanics, 16-47, 2022 | 2 | 2022 |
Subject-Specific Stiffness Customization of Cementless Femoral Stem for Optimal Interfacial Bone Growth S Chatterjee IIEST Shibpur,, 2017 | 1 | 2017 |
Biomechanical analysis to probe role of bone condition and bodyweight in stiffness customization of femoral stem for improved periprosthetic 2 biomechanical response 3 S Chatterjee, S Roy, S Majumder, B Basu, A RoyChowdhury | | 2020 |
Design & Simulation of Lumber Artificial Intervertibral Disc S Dey, J Biswas, S Chatterjee, S Karmakar, S Majumder, AR Choudhury | | |
Effect of the femoral stem size on femur bone quality towards THR PK Maji, AR Chowdhury, D Datta, S Karmakar, S Chatterjee, AK Prasad | | |