BEAM: a Monte Carlo code to simulate radiotherapy treatment units DWO Rogers, BA Faddegon, GX Ding, CM Ma, J We, TR Mackie Medical physics 22 (5), 503-524, 1995 | 1906 | 1995 |
Small fields: nonequilibrium radiation dosimetry IJ Das, GX Ding, A Ahnesjö Medical physics 35 (1), 206-215, 2008 | 943 | 2008 |
A study on adaptive IMRT treatment planning using kV cone-beam CT GX Ding, DM Duggan, CW Coffey, M Deeley, DE Hallahan, A Cmelak, ... Radiotherapy and Oncology 85 (1), 116-125, 2007 | 275 | 2007 |
Energy spectra, angular spread, fluence profiles and dose distributions of 6 and 18 MV photon beams: results of Monte Carlo simulations for a Varian 2100EX accelerator GX Ding Physics in Medicine & Biology 47 (7), 1025, 2002 | 235 | 2002 |
Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure GX Ding, CW Coffey International Journal of Radiation Oncology* Biology* Physics 73 (2), 610-617, 2009 | 214 | 2009 |
Accurate patient dosimetry of kilovoltage cone‐beam CT in radiation therapy GX Ding, DM Duggan, CW Coffey Medical physics 35 (3), 1135-1144, 2008 | 214 | 2008 |
Image guidance doses delivered during radiotherapy: Quantification, management, and reduction: Report of the AAPM Therapy Physics Committee Task Group 180 GX Ding, P Alaei, B Curran, R Flynn, M Gossman, TR Mackie, M Miften, ... Medical physics 45 (5), e84-e99, 2018 | 166 | 2018 |
Calculation of stopping‐power ratios using realistic clinical electron beams GX Ding, DWO Rogers, TR Mackie Medical physics 22 (5), 489-501, 1995 | 163 | 1995 |
R50 as a beam quality specifier for selecting stopping‐power ratios and reference depths for electron dosimetry DT Burns, GX Ding, DWO Rogers Medical physics 23 (3), 383-388, 1996 | 158 | 1996 |
Comparison of manual and automatic segmentation methods for brain structures in the presence of space-occupying lesions: a multi-expert study MA Deeley, A Chen, R Datteri, JH Noble, AJ Cmelak, EF Donnelly, ... Physics in Medicine & Biology 56 (14), 4557, 2011 | 156 | 2011 |
Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy GX Ding, DM Duggan, CW Coffey Physics in Medicine & Biology 52 (6), 1595, 2007 | 156 | 2007 |
Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning JE Cygler, GM Daskalov, GH Chan, GX Ding Medical physics 31 (1), 142-153, 2004 | 153 | 2004 |
ICRU Report 91: prescribing, recording, and reporting of stereotactic treatments with small photon beams J Seuntjens J ICRU 14, 2014 | 141 | 2014 |
Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods GX Ding, DM Duggan, CW Coffey Physics in Medicine & Biology 51 (10), 2549, 2006 | 141 | 2006 |
Impact of inhomogeneity corrections on dose coverage in the treatment of lung cancer using stereotactic body radiation therapy GX Ding, DM Duggan, B Lu, DE Hallahan, A Cmelak, A Malcolm, ... Medical physics 34 (7), 2985-2994, 2007 | 120 | 2007 |
Radiation exposure to patients from image guidance procedures and techniques to reduce the imaging dose GX Ding, P Munro Radiotherapy and Oncology 108 (1), 91-98, 2013 | 119 | 2013 |
Reducing radiation exposure to patients from kV-CBCT imaging GX Ding, P Munro, J Pawlowski, A Malcolm, CW Coffey Radiotherapy and Oncology 97 (3), 585-592, 2010 | 115 | 2010 |
A comparison of electron beam dose calculation accuracy between treatment planning systems using either a pencil beam or a Monte Carlo algorithm GX Ding, JE Cygler, WY Christine, NI Kalach, G Daskalov International Journal of Radiation Oncology* Biology* Physics 63 (2), 622-633, 2005 | 108 | 2005 |
Energy spectra, angular spread, and dose distributions of electron beams from various accelerators used in radiotherapy GX Ding, DWO Rogers National Research Council of Canada Report, 1995 | 100 | 1995 |
Report of AAPM Task Group 155: megavoltage photon beam dosimetry in small fields and non‐equilibrium conditions IJ Das, P Francescon, JM Moran, A Ahnesjö, MM Aspradakis, CW Cheng, ... Medical physics 48 (10), e886-e921, 2021 | 99 | 2021 |