Quantitative assessment of the effects of high‐permittivity pads in 7 Tesla MRI of the brain WM Teeuwisse, WM Brink, AG Webb Magnetic resonance in medicine 67 (5), 1285-1293, 2012 | 274 | 2012 |
Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate‐based dielectric WM Teeuwisse, WM Brink, KN Haines, AG Webb Magnetic resonance in medicine 67 (4), 912-918, 2012 | 169 | 2012 |
High permittivity pads reduce specific absorption rate, improve B1 homogeneity, and increase contrast‐to‐noise ratio for functional cardiac MRI at 3 T WM Brink, AG Webb Magnetic resonance in medicine 71 (4), 1632-1640, 2014 | 113 | 2014 |
High permittivity dielectric pads improve high spatial resolution magnetic resonance imaging of the inner ear at 7 T WM Brink, AMA van der Jagt, MJ Versluis, BM Verbist, AG Webb Investigative radiology 49 (5), 271-277, 2014 | 84 | 2014 |
Increasing signal homogeneity and image quality in abdominal imaging at 3 T with very high permittivity materials P De Heer, WM Brink, BJ Kooij, AG Webb Magnetic resonance in medicine 68 (4), 1317-1324, 2012 | 70 | 2012 |
Practical improvements in the design of high permittivity pads for dielectric shimming in neuroimaging at 7 T TPA O’Reilly, AG Webb, WM Brink Journal of magnetic resonance 270, 108-114, 2016 | 58 | 2016 |
Clinical applications of dual‐channel transmit MRI: A review WM Brink, V Gulani, AG Webb Journal of Magnetic Resonance Imaging 42 (4), 855-869, 2015 | 49 | 2015 |
3-D contrast source inversion-electrical properties tomography RL Leijsen, WM Brink, CAT Van Den Berg, AG Webb, RF Remis IEEE transactions on medical imaging 37 (9), 2080-2089, 2018 | 45 | 2018 |
Electrical properties tomography: A methodological review R Leijsen, W Brink, C van den Berg, A Webb, R Remis Diagnostics 11 (2), 176, 2021 | 43 | 2021 |
A theoretical approach based on electromagnetic scattering for analysing dielectric shimming in high‐field MRI WM Brink, RF Remis, AG Webb Magnetic resonance in medicine 75 (5), 2185-2194, 2016 | 41 | 2016 |
Studying neurons and glia non-invasively via anomalous subdiffusion of intracellular metabolites C Ingo, W Brink, E Ercan, AG Webb, I Ronen Brain Structure and Function 223, 3841-3854, 2018 | 37 | 2018 |
High‐permittivity pad design tool for 7T neuroimaging and 3T body imaging J van Gemert, W Brink, A Webb, R Remis Magnetic Resonance in Medicine 81 (5), 3370-3378, 2019 | 35 | 2019 |
Visualization of human inner ear anatomy with high-resolution MR imaging at 7T: initial clinical assessment MA Van der Jagt, WM Brink, MJ Versluis, SCA Steens, JJ Briaire, ... American Journal of Neuroradiology 36 (2), 378-383, 2015 | 35 | 2015 |
A simple head‐sized phantom for realistic static and radiofrequency characterization at high fields WM Brink, Z Wu, AG Webb Magnetic resonance in medicine 80 (4), 1738-1745, 2018 | 33 | 2018 |
Improved image quality and reduced power deposition in the spine at 3 T using extremely high permittivity materials K Koolstra, P Börnert, W Brink, A Webb Magnetic resonance in medicine 79 (2), 1192-1199, 2018 | 33 | 2018 |
The effect of high-permittivity pads on specific absorption rate in radiofrequency-shimmed dual-transmit cardiovascular magnetic resonance at 3T WM Brink, JS van den Brink, AG Webb Journal of cardiovascular magnetic resonance 17 (1), 82, 2015 | 33 | 2015 |
An efficient methodology for the analysis of dielectric shimming materials in magnetic resonance imaging JHF Van Gemert, W Brink, A Webb, R Remis IEEE transactions on medical imaging 36 (2), 666-673, 2016 | 29 | 2016 |
Passive radiofrequency shimming in the thighs at 3 Tesla using high permittivity materials and body coil receive uniformity correction WM Brink, MJ Versluis, JM Peeters, P Börnert, AG Webb Magnetic resonance in medicine 76 (6), 1951-1956, 2016 | 21 | 2016 |
Diffusion‐prepared neurography of the brachial plexus with a large field‐of‐view at 3T J Oudeman, BF Coolen, V Mazzoli, M Maas, C Verhamme, WM Brink, ... Journal of Magnetic Resonance Imaging 43 (3), 644-654, 2016 | 21 | 2016 |
Ventricular B1+ perturbation at 7 T - real effect or measurement artifact? WM Brink, P Börnert, K Nehrke, AG Webb NMR in Biomedicine 27 (6), 2014 | 20 | 2014 |