Segui
Luca Mesin
Luca Mesin
Email verificata su polito.it
Titolo
Citata da
Citata da
Anno
A surface EMG generation model with multilayer cylindrical description of the volume conductor
D Farina, L Mesin, S Martina, R Merletti
IEEE Transactions on Biomedical Engineering 51 (3), 415-426, 2004
2892004
Surface EMG: the issue of electrode location
L Mesin, R Merletti, A Rainoldi
Journal of Electromyography and Kinesiology 19 (5), 719-726, 2009
2682009
Assessment of force and fatigue in isometric contractions of the upper trapezius muscle by surface EMG signal and perceived exertion scale
A Troiano, F Naddeo, E Sosso, G Camarota, R Merletti, L Mesin
Gait & posture 28 (2), 179-186, 2008
2202008
Automatic segmentation of surface EMG images: Improving the estimation of neuromuscular activity
TMM Vieira, R Merletti, L Mesin
Journal of biomechanics 43 (11), 2149-2158, 2010
1342010
A bi-dimensional index for the selective assessment of myoelectric manifestations of peripheral and central muscle fatigue
L Mesin, C Cescon, M Gazzoni, R Merletti, A Rainoldi
Journal of Electromyography and Kinesiology 19 (5), 851-863, 2009
1182009
Multichannel surface EMG for the non-invasive assessment of the anal sphincter muscle
R Merletti, A Bottin, C Cescon, D Farina, M Gazzoni, S Martina, L Mesin, ...
Digestion 69 (2), 112-122, 2004
1092004
New system for detecting road ice formation
A Troiano, E Pasero, L Mesin
IEEE Transactions on Instrumentation and Measurement 60 (3), 1091-1101, 2010
992010
A finite element model for describing the effect of muscle shortening on surface EMG
L Mesin, M Joubert, T Hanekom, R Merletti, D Farina
IEEE transactions on biomedical engineering 53 (4), 593-600, 2006
962006
Insights gained into the interpretation of surface electromyograms from the gastrocnemius muscles: a simulation study
L Mesin, R Merletti, TMM Vieira
Journal of biomechanics 44 (6), 1096-1103, 2011
932011
Connectivity analysis in EEG data: a tutorial review of the state of the art and emerging trends
G Chiarion, L Sparacino, Y Antonacci, L Faes, L Mesin
Bioengineering 10 (3), 372, 2023
912023
Investigation of motor unit recruitment during stimulated contractions of tibialis anterior muscle
L Mesin, E Merlo, R Merletti, C Orizio
Journal of Electromyography and Kinesiology 20 (4), 580-589, 2010
822010
Use of electromyographic and electrocardiographic signals to detect sleep bruxism episodes in a natural environment
T Castroflorio, L Mesin, GM Tartaglia, C Sforza, D Farina
IEEE journal of biomedical and health informatics 17 (6), 994-1001, 2013
752013
Effect of spatial filtering on crosstalk reduction in surface EMG recordings
L Mesin, S Smith, S Hugo, S Viljoen, T Hanekom
Medical engineering & physics 31 (3), 374-383, 2009
742009
Simulation of surface EMG signals generated by muscle tissues with inhomogeneity due to fiber pinnation
L Mesin, D Farina
IEEE transactions on biomedical engineering 51 (9), 1521-1529, 2004
672004
Crosstalk in surface electromyogram: literature review and some insights
L Mesin
Physical and Engineering Sciences in Medicine 43, 481-492, 2020
602020
Dysregulation of the autonomous nervous system in patients with temporomandibular disorder: a pupillometric study
A Monaco, R Cattaneo, L Mesin, I Ciarrocchi, F Sgolastra, D Pietropaoli
Public Library of Science 7 (9), e45424, 2012
562012
Comparison of spatial filter selectivity in surface myoelectric signal detection: influence of the volume conductor model
D Farina, L Mesin, S Martina, R Merletti
Medical and Biological Engineering and Computing 42, 114-120, 2004
532004
Advances in surface electromyographic signal simulation with analytical and numerical descriptions of the volume conductor
D Farina, L Mesin, S Martina
Medical and Biological Engineering and Computing 42, 467-476, 2004
492004
Fundamental concepts of bipolar and high-Density surface EMG understanding and teaching for clinical, occupational, and sport applications: Origin, detection, and main errors
I Campanini, A Merlo, C Disselhorst-Klug, L Mesin, S Muceli, R Merletti
Sensors 22 (11), 4150, 2022
472022
Distribution of electrical stimulation current in a planar multilayer anisotropic tissue
L Mesin, R Merletti
IEEE Transactions on Biomedical Engineering 55 (2), 660-670, 2008
452008
Il sistema al momento non può eseguire l'operazione. Riprova più tardi.
Articoli 1–20