Assessment of the acoustic properties of common tissue-mimicking test phantoms JE Browne, KV Ramnarine, AJ Watson, PR Hoskins Ultrasound in medicine & biology 29 (7), 1053-1060, 2003 | 272 | 2003 |
Review of the different methods for assessing standing balance JE Browne, NJ O'Hare Physiotherapy 87 (9), 489-495, 2001 | 217 | 2001 |
Novel tissue mimicking materials for high frequency breast ultrasound phantoms LM Cannon, AJ Fagan, JE Browne Ultrasound in medicine & biology 37 (1), 122-135, 2011 | 106 | 2011 |
The speed of sound and attenuation of an IEC agar-based tissue-mimicking material for high frequency ultrasound applications C Sun, SD Pye, JE Browne, A Janeczko, B Ellis, MB Butler, V Sboros, ... Ultrasound in medicine & biology 38 (7), 1262-1270, 2012 | 90 | 2012 |
Assessment of the accuracy of an ultrasound elastography liver scanning system using a PVA-cryogel phantom with optimal acoustic and mechanical properties S Cournane, L Cannon, JE Browne, AJ Fagan Physics in Medicine & Biology 55 (19), 5965, 2010 | 89 | 2010 |
Objective measurements of image quality JE Browne, AJ Watson, NM Gibson, NJ Dudley, AT Elliott Ultrasound in medicine & biology 30 (2), 229-237, 2004 | 82 | 2004 |
Development of a vessel-mimicking material for use in anatomically realistic Doppler flow phantoms DM King, CM Moran, JD McNamara, AJ Fagan, JE Browne Ultrasound in medicine & biology 37 (5), 813-826, 2011 | 81 | 2011 |
A quality control procedure for force platforms J Browne, N O'Hare Physiological measurement 21 (4), 515, 2000 | 77 | 2000 |
A review of Doppler ultrasound quality assurance protocols and test devices JE Browne Physica Medica 30 (7), 742-751, 2014 | 59 | 2014 |
Review of ultrasound elastography quality control and training test phantoms S Cournane, AJ Fagan, JE Browne Ultrasound 20 (1), 16-23, 2012 | 59 | 2012 |
The effects of fatty deposits on the accuracy of the Fibroscan® liver transient elastography ultrasound system S Cournane, JE Browne, AJ Fagan Physics in Medicine & Biology 57 (12), 3901, 2012 | 52 | 2012 |
Breast cancer detection using interferometric MUSIC: Experimental and numerical assessment G Ruvio, R Solimene, A Cuccaro, D Gaetano, JE Browne, MJ Ammann Medical physics 41 (10), 103101, 2014 | 48 | 2014 |
Validation of a sensitivity performance index test protocol and evaluation of colour Doppler sensitivity for a range of ultrasound scanners JE Browne, AJ Watson, PR Hoskins, AT Elliott Ultrasound in medicine & biology 30 (11), 1475-1483, 2004 | 42 | 2004 |
Development of a novel method for assessing balance: the quantitative posturography system J Browne, N O'Hare Physiological measurement 21 (4), 525, 2000 | 40 | 2000 |
Multimodal breast phantoms for microwave, ultrasound, mammography, magnetic resonance and computed tomography imaging G Ruvio, R Solimene, A Cuccaro, G Fiaschetti, AJ Fagan, S Cournane, ... Sensors 20 (8), 2400, 2020 | 39 | 2020 |
Investigation of the effect of subcutaneous fat on image quality performance of 2D conventional imaging and tissue harmonic imaging JE Browne, AJ Watson, PR Hoskins, AT Elliott Ultrasound in medicine & biology 31 (7), 957-964, 2005 | 36 | 2005 |
Clinical assessment of the quantitative posturography system J Browne, N O'Hare, G O'Hare, A Finn, J Colin Physiotherapy 88 (4), 217-223, 2002 | 35 | 2002 |
Practical implementation of robust MR-thermometry during clinical MR-guided microwave ablations in the liver at 1.5 T KR Gorny, CP Favazza, A Lu, JP Felmlee, NJ Hangiandreou, JE Browne, ... Physica Medica 67, 91-99, 2019 | 31 | 2019 |
Footwear antennas for body area telemetry D Gaetano, P McEvoy, MJ Ammann, JE Browne, L Keating, F Horgan IEEE Transactions on Antennas and Propagation 61 (10), 4908-4916, 2013 | 30 | 2013 |
Development of a range of anatomically realistic renal artery flow phantoms DM King, M Ring, CM Moran, JE Browne Ultrasound in medicine & biology 36 (7), 1135-1144, 2010 | 24 | 2010 |