The design of a four-rod RFQ LINAC for VEC-RIB facility A Chakrabarti, V Naik, O Kamigaito, S Dechoudhury, D Bhowmick, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2004 | 21 | 2004 |
Design and development of a radio frequency quadrupole linac postaccelerator for the Variable Energy Cyclotron Center rare ion beam project S Dechoudhury, V Naik, M Mondal, A Chatterjee, HK Pandey, TK Mandi, ... Review of Scientific Instruments 81 (2), 2010 | 19 | 2010 |
Nanoemulsion: A review RK Chouksey, HK Pandey, A Maithil, AK Jain Inventi Rapid: Pharm Tech 2 (1), 231-235, 2011 | 16 | 2011 |
Design of LINAC post-accelerator for VECC RIB facility using realistic field A Bandyopadhyay, O Kamigaito, SK Nayak, HK Pandey, M Mondal, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2006 | 16 | 2006 |
33.7 MHz heavy-ion radio frequency quadrupole linac at VECC Kolkata A Chakrabarti, V Naik, S Dechoudhury, A Bandyopadhyay, M Mondal, ... Review of scientific instruments 78 (4), 2007 | 15 | 2007 |
In vivo assessment of atorvastatin nanoemulsion formulation R Chouksey, AK Jain, H Pandey, A Maithil Bulletin of Pharmaceutical Research 1 (2), 10-14, 2011 | 11 | 2011 |
Improvement in phase-sensitivity of a Mach–Zehnder interferometer with the superposition of Schrödinger’s cat-like state with vacuum state as an input under parity measurement G Shukla, KM Mishra, AK Pandey, T Kumar, H Pandey, DK Mishra Optical and Quantum Electronics 55 (5), 460, 2023 | 9 | 2023 |
First online production of radioactive ion beams at VECC V Naik, A Chakrabarti, M Bhattacharjee, P Karmakar, S Bhattacharjee, ... Nuclear Instruments and Methods in Physics Research Section B: Beam …, 2013 | 9 | 2013 |
A gas-jet transport and catcher technique for on-line production of radioactive ion beams using an electron cyclotron resonance ion-source V Naik, A Chakrabarti, M Bhattacharjee, P Karmakar, A Bandyopadhyay, ... Review of Scientific Instruments 84 (3), 2013 | 9 | 2013 |
Design of a “two-ion source” Charge Breeder using ECR ion source in two frequency mode D Naik, V Naik, A Chakrabarti, S Dechoudhury, SK Nayak, HK Pandey, ... Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2005 | 9 | 2005 |
Rare Ion Beam Facility At Kolkata-Present State Of Development A Bandyopadhyay, D Bhowmick, S Basak, A Chakrabarti, PS Chauhan, ... PAC 9, 5053, 2009 | 7* | 2009 |
Physics design of rod type proton Radio Frequency Quadrupole linac C Das, S Dechoudhury, HK Pandey, V Naik, A Chakrabarti Journal of Instrumentation 12 (02), T02005, 2017 | 5 | 2017 |
A rare case of a phyllodes tumour of the breast converting to a fibrosarcoma with successful treatment NK Pant, A Singh, D Kumar, H Pandey ecancermedicalscience 6, 2012 | 5 | 2012 |
Post-accelerator LINAC development for the RIB facility project at VECC, Kolkata A Bandyopadhyay, M Mondal, HK Pandey, T Mandi, A Chakrabarti Proceedings of the LINAC08, Victoria, BC, Canada. Paper ID MOP020, 2008 | 5 | 2008 |
Design of a gas-jet coupled ECR ion-source for ISOL type RIB facility M Bhattacharjee, HK Pandey, V Naik, A Chakrabarti Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2020 | 2 | 2020 |
Mapping groundwater potential zones in Meja Block, Allahabad district using remote sensing and GIS techniques V Tiwari, S Suman, HK Pandey, D Lal International Journal of Pure & Applied Bioscience 6 (5), 573-583, 2018 | 2 | 2018 |
Development of deflector cavity and RF amplifier for bunch length detector system HK Pandey, TK Bhattacharya, A Chakrabarti Journal of Instrumentation 11 (02), T02001, 2016 | 2 | 2016 |
Design and development of deflector cavity for the non-interceptive bunch length measurement system HK Pandey, S Dechoudhury, DP Dutta, TK Mandi, TK Bhattacharya, ... IOP Conference Series: Materials Science and Engineering 67 (1), 012006, 2014 | 2 | 2014 |
Simulation analysis of analog IQ based LLRF control of RF cavity S Basak, H Pandey, A Chakrabarti Proceedings of PCaPAC2012, Kolkata, 2012 | 2 | 2012 |
Design of medium energy beam transport line between the RFQ and the Linac in the radioactive ion beam facility at VECC, Kolkata S Dechoudhury, V Naik, M Mondal, HK Pandey, A Chatterjee, D Sanyal, ... Pramana 75, 485-499, 2010 | 2 | 2010 |