Targeted radiotherapy with gold nanoparticles: current status and future perspectives W Ngwa, R Kumar, S Sridhar, H Korideck, P Zygmanski, RA Cormack, ... Nanomedicine 9 (7), 1063-1082, 2014 | 201 | 2014 |
The measurement of proton stopping power using proton-cone-beam computed tomography P Zygmanski, KP Gall, MSZ Rabin, SJ Rosenthal Physics in Medicine & Biology 45 (2), 511, 2000 | 141 | 2000 |
Dependence of Monte Carlo microdosimetric computations on the simulation geometry of gold nanoparticles P Zygmanski, B Liu, P Tsiamas, F Cifter, M Petersheim, J Hesser, E Sajo Physics in Medicine & Biology 58 (22), 7961, 2013 | 110 | 2013 |
Impact of beam quality on megavoltage radiotherapy treatment techniques utilizing gold nanoparticles for dose enhancement P Tsiamas, B Liu, F Cifter, WF Ngwa, RI Berbeco, C Kappas, K Theodorou, ... Physics in Medicine & Biology 58 (3), 451, 2013 | 102 | 2013 |
Angular dose dependency of MatriXX TM and its calibration LD Wolfsberger, M Wagar, P Nitsch, MS Bhagwat, P Zygmanski Journal of applied clinical medical physics 11 (1), 241-251, 2010 | 101 | 2010 |
LINAC based stereotactic radiosurgery for multiple brain metastases: guidance for clinical implementation D Hartgerink, A Swinnen, D Roberge, A Nichol, P Zygmanski, FF Yin, ... Acta Oncologica 58 (9), 1275-1282, 2019 | 89 | 2019 |
Nanoscale radiation transport and clinical beam modeling for gold nanoparticle dose enhanced radiotherapy (GNPT) using X-rays P Zygmanski, E Sajo The British journal of radiology 89 (1059), 20150200, 2016 | 86 | 2016 |
Flexible perovskite based X-ray detectors for dose monitoring in medical imaging applications HS Gill, B Elshahat, A Kokil, L Li, R Mosurkal, P Zygmanski, E Sajo, ... Physics in Medicine 5, 20-23, 2018 | 83 | 2018 |
Dependence of fluence errors in dynamic IMRT on leaf‐positional errors varying with time and leaf number P Zygmanski, JH Kung, SB Jiang, L Chin Medical physics 30 (10), 2736-2749, 2003 | 61 | 2003 |
Evaluation of MatriXX for IMRT and VMAT dose verifications in peripheral dose regions Z Han, SK Ng, MS Bhagwat, Y Lyatskaya, P Zygmanski Medical physics 37 (7Part1), 3704-3714, 2010 | 51 | 2010 |
Method of identifying dynamic multileaf collimator irradiation that is highly sensitive to a systematic MLC calibration error P Zygmanski, JH Kung Medical physics 28 (11), 2220-2226, 2001 | 50 | 2001 |
The effect of flattening filter free delivery on endothelial dose enhancement with gold nanoparticles A Detappe, P Tsiamas, W Ngwa, P Zygmanski, M Makrigiorgos, ... Medical physics 40 (3), 031706, 2013 | 45 | 2013 |
A stochastic model of cell survival for high‐Z nanoparticle radiotherapy P Zygmanski, W Hoegele, P Tsiamas, F Cifter, W Ngwa, R Berbeco, ... Medical physics 40 (2), 024102, 2013 | 42 | 2013 |
Evaluation of radiation dose delivered by cone beam CT and tomosynthesis employed for setup of external breast irradiation B Winey, P Zygmanski, Y Lyatskaya Medical Physics 36 (1), 164-173, 2009 | 41 | 2009 |
A method of calculating a lung clinical target volume DVH for IMRT with intrafractional motion JH Kung, P Zygmanski, N Choi, GTY Chen Medical Physics 30 (6), 1103-1109, 2003 | 41 | 2003 |
Low‐cost flexible thin‐film detector for medical dosimetry applications P Zygmanski, C Abkai, Z Han, Y Shulevich, D Menichelli, J Hesser Journal of Applied Clinical Medical Physics 15 (2), 311-326, 2014 | 38 | 2014 |
Beam quality and dose perturbation of 6 MV flattening-filter-free linac P Tsiamas, E Sajo, F Cifter, K Theodorou, C Kappas, M Makrigiorgos, ... Physica Medica 30 (1), 47-56, 2014 | 38 | 2014 |
An MLC‐based linac QA procedure for the characterization of radiation isocenter and room lasers’ position F Rosca, F Lorenz, FL Hacker, LM Chin, N Ramakrishna, P Zygmanski Medical Physics 33 (6Part1), 1780-1787, 2006 | 38 | 2006 |
Determination of depth and field size dependence of multileaf collimator transmission in intensity‐modulated radiation therapy beams P Zygmanski, F Rosca, D Kadam, F Lorenz, A Nalichowski, L Court, ... Journal of Applied Clinical Medical Physics 8 (4), 76-95, 2007 | 37 | 2007 |
A Monte Carlo study of I-125 prostate brachytherapy with gold nanoparticles: dose enhancement with simultaneous rectal dose sparing via radiation shielding D Brivio, PL Nguyen, E Sajo, W Ngwa, P Zygmanski Physics in Medicine & Biology 62 (5), 1935, 2017 | 32 | 2017 |