Wear and lubrication of metal-on-metal hip implants. FW Chan, JD Bobyn, JB Medley, JJ Krygier, M Tanzer Clinical Orthopaedics and Related Research (1976-2007) 369, 10-24, 1999 | 390 | 1999 |
Engineering issues and wear performance of metal on metal hip implants FW Chan, JD Bobyn, JB Medley, JJ Krygier, S Yue, M Tanzer Clinical Orthopaedics and Related Research® 333, 96-107, 1996 | 200 | 1996 |
Comparison of alloys and designs in a hip simulator study of metal on metal implants. JB Medley, FW Chan, JJ Krygier, JD Bobyn Clinical Orthopaedics and Related Research (1976-2007) 329, S148-S159, 1996 | 188 | 1996 |
Metal on metal total hip replacement workshop consensus document HC Amstutz, P Campbell, H McKellop, TP Schmalzried, WJ Gillespie, ... Clinical Orthopaedics and Related Research® 329, S297-S303, 1996 | 146 | 1996 |
Size, shape, and composition of wear particles from metal–metal hip simulator testing: effects of alloy and number of loading cycles I Catelas, JD Bobyn, JB Medley, JJ Krygier, DJ Zukor, OL Huk Journal of Biomedical Materials Research Part A 67 (1), 312-327, 2003 | 136 | 2003 |
Comparison of in vitro with in vivo characteristics of wear particles from metal–metal hip implants I Catelas, JB Medley, PA Campbell, OL Huk, JD Bobyn Journal of Biomedical Materials Research Part B: Applied Biomaterials: An …, 2004 | 126 | 2004 |
Transient elastohydrodynamic lubrication models for the human ankle joint JB Medley, D Dowson, V Wright Engineering in medicine 13 (3), 137-151, 1984 | 119 | 1984 |
Imaging protein deposits on contact lens materials JH Teichroeb, JA Forrest, V Ngai, JW Martin, L Jones, J Medley Optometry and Vision Science 85 (12), 1151-1164, 2008 | 104 | 2008 |
Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time I Catelas, PA Campbell, JD Bobyn, JB Medley, OL Huk Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006 | 97 | 2006 |
Effects of digestion protocols on the isolation and characterization of metal–metal wear particles. I. Analysis of particle size and shape I Catelas, JD Bobyn, JB Medley, JJ Krygier, DJ Zukor, A Petit, OL Huk Journal of Biomedical Materials Research: An Official Journal of The Society …, 2001 | 85 | 2001 |
The effect of microstructure on the wear of cobalt-based alloys used in metal-on-metal hip implants R Varano, JD Bobyn, JB Medley, S Yue Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006 | 82 | 2006 |
Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter GDG Langohr, R Willing, JB Medley, GS Athwal, JA Johnson Journal of shoulder and elbow surgery 25 (4), 589-597, 2016 | 76 | 2016 |
Low wear ball and cup joint prosthesis AL Lippincott III, JB Medley US Patent 6,059,830, 2000 | 73 | 2000 |
Kinematics of the MATCO™ hip simulator and issues related to wear testing of metal-metal implants JB Medley, JJ Krygier, JD Bobyn, FW Chan, A Lippincott, M Tanzer Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 1997 | 71 | 1997 |
Surface characterization of metal-on-metal hip implants tested in a hip simulator A Wang, S Yue, JD Bobyn, FW Chan, JB Medley Wear 225, 708-715, 1999 | 66 | 1999 |
Biochemical comparisons of osteoarthritic human synovial fluid with calf sera used in knee simulator wear testing JM Brandt, LK Brière, J Marr, SJ MacDonald, RB Bourne, JB Medley Journal of Biomedical Materials Research Part A 94 (3), 961-971, 2010 | 64 | 2010 |
Fluid film lubrication in artificial hip joints ZM Jin, JB Medley, D Dowson Tribology series 41, 237-256, 2003 | 54 | 2003 |
Numerical analysis of time-varying fluid film thickness in metal-metal hip implants in simulator tests FW Chan, JB Medley, JD Bobyn, JJ Krygier Alternative bearing surfaces in total joint replacement, 111-128, 1998 | 47 | 1998 |
Investigation of microstructure, mechanical properties and cellular viability of poly (L-lactic acid) tissue engineering scaffolds prepared by different thermally induced phase … S Molladavoodi, M Gorbet, J Medley, HJ Kwon Journal of the Mechanical Behavior of Biomedical Materials 17, 186-197, 2013 | 46 | 2013 |
Incorporating ligament laxity in a finite element model for the upper cervical spine TL Lasswell, DS Cronin, JB Medley, P Rasoulinejad The Spine Journal 17 (11), 1755-1764, 2017 | 40 | 2017 |