フォロー
John B Medley
John B Medley
Professor Emeritus, Mechanical and Mechatronics Engineering, University of Waterloo
確認したメール アドレス: uwaterloo.ca - ホームページ
タイトル
引用先
引用先
Wear and lubrication of metal-on-metal hip implants.
FW Chan, JD Bobyn, JB Medley, JJ Krygier, M Tanzer
Clinical Orthopaedics and Related Research (1976-2007) 369, 10-24, 1999
3901999
Engineering issues and wear performance of metal on metal hip implants
FW Chan, JD Bobyn, JB Medley, JJ Krygier, S Yue, M Tanzer
Clinical Orthopaedics and Related Research® 333, 96-107, 1996
2001996
Comparison of alloys and designs in a hip simulator study of metal on metal implants.
JB Medley, FW Chan, JJ Krygier, JD Bobyn
Clinical Orthopaedics and Related Research (1976-2007) 329, S148-S159, 1996
1881996
Metal on metal total hip replacement workshop consensus document
HC Amstutz, P Campbell, H McKellop, TP Schmalzried, WJ Gillespie, ...
Clinical Orthopaedics and Related Research® 329, S297-S303, 1996
1461996
Size, shape, and composition of wear particles from metal–metal hip simulator testing: effects of alloy and number of loading cycles
I Catelas, JD Bobyn, JB Medley, JJ Krygier, DJ Zukor, OL Huk
Journal of Biomedical Materials Research Part A 67 (1), 312-327, 2003
1362003
Comparison of in vitro with in vivo characteristics of wear particles from metal–metal hip implants
I Catelas, JB Medley, PA Campbell, OL Huk, JD Bobyn
Journal of Biomedical Materials Research Part B: Applied Biomaterials: An …, 2004
1262004
Transient elastohydrodynamic lubrication models for the human ankle joint
JB Medley, D Dowson, V Wright
Engineering in medicine 13 (3), 137-151, 1984
1191984
Imaging protein deposits on contact lens materials
JH Teichroeb, JA Forrest, V Ngai, JW Martin, L Jones, J Medley
Optometry and Vision Science 85 (12), 1151-1164, 2008
1042008
Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time
I Catelas, PA Campbell, JD Bobyn, JB Medley, OL Huk
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006
972006
Effects of digestion protocols on the isolation and characterization of metal–metal wear particles. I. Analysis of particle size and shape
I Catelas, JD Bobyn, JB Medley, JJ Krygier, DJ Zukor, A Petit, OL Huk
Journal of Biomedical Materials Research: An Official Journal of The Society …, 2001
852001
The effect of microstructure on the wear of cobalt-based alloys used in metal-on-metal hip implants
R Varano, JD Bobyn, JB Medley, S Yue
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006
822006
Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter
GDG Langohr, R Willing, JB Medley, GS Athwal, JA Johnson
Journal of shoulder and elbow surgery 25 (4), 589-597, 2016
762016
Low wear ball and cup joint prosthesis
AL Lippincott III, JB Medley
US Patent 6,059,830, 2000
732000
Kinematics of the MATCO™ hip simulator and issues related to wear testing of metal-metal implants
JB Medley, JJ Krygier, JD Bobyn, FW Chan, A Lippincott, M Tanzer
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 1997
711997
Surface characterization of metal-on-metal hip implants tested in a hip simulator
A Wang, S Yue, JD Bobyn, FW Chan, JB Medley
Wear 225, 708-715, 1999
661999
Biochemical comparisons of osteoarthritic human synovial fluid with calf sera used in knee simulator wear testing
JM Brandt, LK Brière, J Marr, SJ MacDonald, RB Bourne, JB Medley
Journal of Biomedical Materials Research Part A 94 (3), 961-971, 2010
642010
Fluid film lubrication in artificial hip joints
ZM Jin, JB Medley, D Dowson
Tribology series 41, 237-256, 2003
542003
Numerical analysis of time-varying fluid film thickness in metal-metal hip implants in simulator tests
FW Chan, JB Medley, JD Bobyn, JJ Krygier
Alternative bearing surfaces in total joint replacement, 111-128, 1998
471998
Investigation of microstructure, mechanical properties and cellular viability of poly (L-lactic acid) tissue engineering scaffolds prepared by different thermally induced phase …
S Molladavoodi, M Gorbet, J Medley, HJ Kwon
Journal of the Mechanical Behavior of Biomedical Materials 17, 186-197, 2013
462013
Incorporating ligament laxity in a finite element model for the upper cervical spine
TL Lasswell, DS Cronin, JB Medley, P Rasoulinejad
The Spine Journal 17 (11), 1755-1764, 2017
402017
現在システムで処理を実行できません。しばらくしてからもう一度お試しください。
論文 1–20