Compared performance of high-sensitivity cameras dedicated to myocardial perfusion SPECT: a comprehensive analysis of phantom and human images L Imbert, S Poussier, PR Franken, B Songy, A Verger, O Morel, D Wolf, ... Journal of Nuclear Medicine 53 (12), 1897-1903, 2012 | 294 | 2012 |
Stress-first protocol for myocardial perfusion SPECT imaging with semiconductor cameras: high diagnostic performances with significant reduction in patient radiation doses M Perrin, W Djaballah, F Moulin, M Claudin, N Veran, L Imbert, S Poussier, ... European journal of nuclear medicine and molecular imaging 42, 1004-1011, 2015 | 77 | 2015 |
Comparison between stress myocardial perfusion SPECT recorded with cadmium-zinc-telluride and Anger cameras in various study protocols A Verger, W Djaballah, N Fourquet, F Rouzet, G Koehl, L Imbert, ... European journal of nuclear medicine and molecular imaging 40, 331-340, 2013 | 60 | 2013 |
Integration of dynamic parameters in the analysis of 18F-FDopa PET imaging improves the prediction of molecular features of gliomas M Ginet, T Zaragori, PY Marie, V Roch, G Gauchotte, F Rech, M Blonski, ... European journal of nuclear medicine and molecular imaging 47, 1381-1390, 2020 | 52 | 2020 |
Use of static and dynamic [18F]-F-DOPA PET parameters for detecting patients with glioma recurrence or progression T Zaragori, M Ginet, PY Marie, V Roch, R Grignon, G Gauchotte, F Rech, ... EJNMMI research 10, 1-10, 2020 | 50 | 2020 |
18F-FDOPA PET for the noninvasive prediction of glioma molecular parameters: a radiomics study T Zaragori, J Oster, V Roch, G Hossu, MB Chawki, R Grignon, C Pouget, ... Journal of Nuclear Medicine 63 (1), 147-157, 2022 | 44 | 2022 |
Head-to-head comparison of image quality between brain 18F-FDG images recorded with a fully digital versus a last-generation analog PET camera J Salvadori, L Imbert, M Perrin, G Karcher, Z Lamiral, PY Marie, A Verger EJNMMI research 9, 1-8, 2019 | 42 | 2019 |
Head-to-head comparison between digital and analog PET of human and phantom images when optimized for maximizing the signal-to-noise ratio from small lesions J Salvadori, F Odille, A Verger, P Olivier, G Karcher, PY Marie, L Imbert EJNMMI physics 7, 1-14, 2020 | 41 | 2020 |
High-quality brain perfusion SPECT images may be achieved with a high-speed recording using 360° CZT camera M Bordonne, MB Chawki, PY Marie, T Zaragori, V Roch, R Grignon, ... EJNMMI physics 7, 1-12, 2020 | 39 | 2020 |
Monte Carlo simulation of digital photon counting PET J Salvadori, J Labour, F Odille, PY Marie, JN Badel, L Imbert, D Sarrut EJNMMI physics 7, 1-19, 2020 | 37 | 2020 |
CZT cameras: A technological jump for myocardial perfusion SPECT L Imbert, PY Marie Journal of Nuclear Cardiology 23, 894-896, 2016 | 34 | 2016 |
Factors affecting the myocardial activity acquired during exercise SPECT with a high-sensitivity cardiac CZT camera as compared with conventional Anger camera A Verger, L Imbert, Y Yagdigul, R Fay, W Djaballah, F Rouzet, N Fourquet, ... European journal of nuclear medicine and molecular imaging 41, 522-528, 2014 | 34 | 2014 |
ECG-gated cardiac FDG PET acquisitions significantly improve detectability of infective endocarditis C Boursier, X Duval, A Bourdon, L Imbert, B Mahida, E Chevalier, ... Cardiovascular Imaging 13 (12), 2691-2693, 2020 | 29 | 2020 |
PET imaging of 68Ga-NODAGA-RGD, as compared with 18F-fluorodeoxyglucose, in experimental rodent models of engrafted glioblastoma S Isal, J Pierson, L Imbert, A Clement, C Collet, S Pinel, N Veran, ... EJNMMI research 8, 1-9, 2018 | 28 | 2018 |
Augmented planar bone scintigraphy obtained from a whole-body SPECT recording of less than 20 min with a high-sensitivity 360 CZT camera S Melki, MB Chawki, PY Marie, L Imbert, A Verger European journal of nuclear medicine and molecular imaging 47, 1329-1331, 2020 | 25 | 2020 |
Dynamic amino-acid PET in neuro-oncology: a prognostic tool becomes essential A Verger, L Imbert, T Zaragori European Journal of Nuclear Medicine and Molecular Imaging, 1-4, 2021 | 21 | 2021 |
Routine evaluation of left ventricular function using CZT-SPECT, with low injected activities and limited recording times M Claudin, L Imbert, W Djaballah, N Veran, S Poussier, V Roch, M Perrin, ... Journal of Nuclear Cardiology 25, 249-256, 2018 | 20 | 2018 |
Health-related quality of life in locally advanced hepatocellular carcinoma treated by either radioembolisation or sorafenib (SARAH trial) H Pereira, M Bouattour, MD Burgio, E Assenat, J Grégory, JP Bronowicki, ... European Journal of Cancer 154, 46-56, 2021 | 19 | 2021 |
Head-to-head comparison of the diagnostic performances of Rubidium-PET and SPECT with CZT camera for the detection of myocardial ischemia in a population of women and … F Hyafil, R Chequer, E Sorbets, C Estellat, G Ducrocq, F Rouzet, T Alfaiate, ... Journal of Nuclear Cardiology 27, 755-768, 2020 | 17 | 2020 |
Tracheobronchitis signs observed on ventilation lung scintigraphy during the course of COVID-19 infection A Verger, A Bahloul, S Melki, G Karcher, L Imbert, PY Marie European Journal of Nuclear Medicine and Molecular Imaging 47, 2709-2710, 2020 | 16 | 2020 |