Computed tomography: principles, design, artifacts, and recent advances J Hsieh SPIE press, 2003 | 2766 | 2003 |
A three‐dimensional statistical approach to improved image quality for multislice helical CT JB Thibault, KD Sauer, CA Bouman, J Hsieh Medical physics 34 (11), 4526-4544, 2007 | 1293 | 2007 |
Low-dose X-ray CT reconstruction via dictionary learning Q Xu, H Yu, X Mou, L Zhang, J Hsieh, G Wang IEEE transactions on medical imaging 31 (9), 1682-1697, 2012 | 772 | 2012 |
Prospectively Gated Transverse Coronary CT Angiography versus Retrospectively Gated Helical Technique: Improved Image Quality and Reduced Radiation Dose1 JP Earls, EL Berman, BA Urban, CA Curry, JL Lane, RS Jennings, ... Radiology 246 (3), 742-753, 2008 | 714 | 2008 |
Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques S Singh, MK Kalra, J Hsieh, PE Licato, S Do, HH Pien, MA Blake Radiology 257 (2), 373-383, 2010 | 557 | 2010 |
Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique P Prakash, MK Kalra, AK Kambadakone, H Pien, J Hsieh, MA Blake, ... Investigative radiology 45 (4), 202-210, 2010 | 502 | 2010 |
Adaptive streak artifact reduction in computed tomography resulting from excessive x‐ray photon noise J Hsieh Medical Physics 25 (11), 2139-2147, 1998 | 487 | 1998 |
Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study S Singh, MK Kalra, MD Gilman, J Hsieh, HH Pien, SR Digumarthy, ... Radiology 259 (2), 565-573, 2011 | 437 | 2011 |
Nonlinear sinogram smoothing for low-dose X-ray CT T Li, X Li, J Wang, J Wen, H Lu, J Hsieh, Z Liang IEEE Transactions on Nuclear Science 51 (5), 2505-2513, 2004 | 410 | 2004 |
An iterative approach to the beam hardening correction in cone beam CT J Hsieh, RC Molthen, CA Dawson, RH Johnson Medical physics 27 (1), 23-29, 2000 | 386 | 2000 |
Fast model-based X-ray CT reconstruction using spatially nonhomogeneous ICD optimization Z Yu, JB Thibault, CA Bouman, KD Sauer, J Hsieh IEEE Transactions on image processing 20 (1), 161-175, 2010 | 376 | 2010 |
Step‐and‐shoot data acquisition and reconstruction for cardiac x‐ray computed tomography J Hsieh, J Londt, M Vass, J Li, X Tang, D Okerlund Medical physics 33 (11), 4236-4248, 2006 | 364 | 2006 |
Radiation dose reduction with chest computed tomography using adaptive statistical iterative reconstruction technique: initial experience P Prakash, MK Kalra, SR Digumarthy, J Hsieh, H Pien, S Singh, ... Journal of computer assisted tomography 34 (1), 40-45, 2010 | 272 | 2010 |
Hardware system design improvement using deep learning algorithms J Hsieh, G Avinash, S Sirohey US Patent 11,003,988, 2021 | 260 | 2021 |
A novel reconstruction algorithm to extend the CT scan field‐of‐view J Hsieh, E Chao, J Thibault, B Grekowicz, A Horst, S McOlash, TJ Myers Medical physics 31 (9), 2385-2391, 2004 | 251 | 2004 |
Computed Tomography: Principles J Hsieh Design, Artifacts, and Recent Advances,, 639, 2003 | 235 | 2003 |
A three-dimensional-weighted cone beam filtered backprojection (CB-FBP) algorithm for image reconstruction in volumetric CT—helical scanning X Tang, J Hsieh, RA Nilsen, S Dutta, D Samsonov, A Hagiwara Physics in Medicine & Biology 51 (4), 855, 2006 | 232 | 2006 |
Computer-simulated radiation dose reduction for abdominal multidetector CT of pediatric patients DP Frush, CC Slack, CL Hollingsworth, GS Bisset, LF Donnelly, J Hsieh, ... American Journal of Roentgenology 179 (5), 1107-1113, 2002 | 232 | 2002 |
Principles and applications of multienergy CT: Report of AAPM Task Group 291 CH McCollough, K Boedeker, D Cody, X Duan, T Flohr, SS Halliburton, ... Medical physics 47 (7), e881-e912, 2020 | 214 | 2020 |
Predictive respiratory gating: a new method to reduce motion artifacts on CT scans. CJ Ritchie, J Hsieh, MF Gard, JD Godwin, Y Kim, CR Crawford Radiology 190 (3), 847-852, 1994 | 203 | 1994 |