Image quality in CT: From physical measurements to model observers FR Verdun, D Racine, JG Ott, MJ Tapiovaara, P Toroi, FO Bochud, ... Physica Medica 31 (8), 823-843, 2015 | 352 | 2015 |
Automated analysis of neuronal morphology, synapse number and synaptic recruitment SK Schmitz, JJJ Hjorth, RMS Joemai, R Wijntjes, S Eijgenraam, ... Journal of neuroscience methods 195 (2), 185-193, 2011 | 220 | 2011 |
Quantitative assessment of selective in-plane shielding of tissues in computed tomography through evaluation of absorbed dose and image quality J Geleijns, M Salvado Artells, WJH Veldkamp, M Lopez Tortosa, ... European radiology 16, 2334-2340, 2006 | 173 | 2006 |
Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT WJH Veldkamp, RMS Joemai, AJ van der Molen, J Geleijns Medical physics 37 (2), 620-628, 2010 | 164 | 2010 |
Automated classification of clustered microcalcifications into malignant and benign types WJH Veldkamp, N Karssemeijer, JDM Otten, JHCL Hendriks Medical Physics 27 (11), 2600-2608, 2000 | 145 | 2000 |
Dose and perceived image quality in chest radiography WJH Veldkamp, LJM Kroft, J Geleijns European journal of radiology 72 (2), 209-217, 2009 | 134 | 2009 |
The value of scatter removal by a grid in full field digital mammography WJH Veldkamp, MAO Thijssen, N Karssemeijer Medical Physics 30 (7), 1712-1718, 2003 | 117 | 2003 |
Normalization of local contrast in mammograms WJH Veldkamp, N Karssemeijer IEEE Transactions on Medical Imaging 19 (7), 731-738, 2000 | 104 | 2000 |
Average glandular dose in digital mammography and digital breast tomosynthesis: comparison of phantom and patient data RW Bouwman, RE Van Engen, KC Young, GJ Den Heeten, ... Physics in Medicine & Biology 60 (20), 7893, 2015 | 71 | 2015 |
Development of a 3D printed anthropomorphic lung phantom for image quality assessment in CT I Hernandez-Giron, JM den Harder, GJ Streekstra, J Geleijns, ... Physica Medica 57, 47-57, 2019 | 66 | 2019 |
Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice WJH Veldkamp, LJM Kroft, MV Boot, BJA Mertens, J Geleijns European radiology 16, 333-341, 2006 | 63 | 2006 |
Comparison of a flexible versus a rigid breast compression paddle: pain experience, projected breast area, radiation dose and technical image quality MJM Broeders, M Ten Voorde, WJH Veldkamp, RE van Engen, ... European radiology 25, 821-829, 2015 | 59 | 2015 |
Metal artifact reduction for CT: Development, implementation, and clinical comparison of a generic and a scanner‐specific technique RMS Joemai, PW de Bruin, WJH Veldkamp, J Geleijns Medical physics 39 (2), 1125-1132, 2012 | 59 | 2012 |
Automated assessment of low contrast sensitivity for CT systems using a model observer I Hernandez‐Giron, J Geleijns, A Calzado, WJH Veldkamp Medical physics 38 (S1), S25-S35, 2011 | 55 | 2011 |
Comparison of eight different digital chest radiography systems: variation in detection of simulated chest disease LJM Kroft, WJH Veldkamp, BJA Mertens, MV Boot, J Geleijns American Journal of Roentgenology 185 (2), 339-346, 2005 | 55 | 2005 |
A technique for simulating the effect of dose reduction on image quality in digital chest radiography WJH Veldkamp, LJM Kroft, JPA van Delft, J Geleijns Journal of Digital Imaging 22, 114-125, 2009 | 54 | 2009 |
16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys AJ Van der Molen, WJH Veldkamp, J Geleijns The British journal of radiology 80 (952), 248-255, 2007 | 52 | 2007 |
Adaptive iterative dose reduction 3D versus filtered back projection in CT: evaluation of image quality RMS Joemai, WJH Veldkamp, LJM Kroft, I Hernandez-Giron, J Geleijns American Journal of Roentgenology 201 (6), 1291-1297, 2013 | 51 | 2013 |
An inter-hospital comparison of patient dose based on clinical indications W Teeuwisse, J Geleijns, W Veldkamp European radiology 17, 1795-1805, 2007 | 50 | 2007 |