A review of virtual sensing technology and application in building systems H Li, D Yu, JE Braun Hvac&R Research 17 (5), 619-645, 2011 | 185 | 2011 |
Performance of a coupled cooling system with earth-to-air heat exchanger and solar chimney H Li, Y Yu, F Niu, M Shafik, B Chen Renewable Energy 62, 468-477, 2014 | 181 | 2014 |
Heat and mass transfer performance analysis and cooling capacity prediction of earth to air heat exchanger F Niu, Y Yu, D Yu, H Li Applied Energy 137, 211-221, 2015 | 170 | 2015 |
Decoupling features and virtual sensors for diagnosis of faults in vapor compression air conditioners H Li, JE Braun International Journal of Refrigeration 30 (3), 546-564, 2007 | 159 | 2007 |
A methodology for diagnosing multiple simultaneous faults in vapor-compression air conditioners H Li, JE Braun HVAC&R Research 13 (2), 369-395, 2007 | 149 | 2007 |
An improved fault detection method for incipient centrifugal chiller faults using the PCA-R-SVDD algorithm G Li, Y Hu, H Chen, L Shen, H Li, M Hu, J Liu, K Sun Energy and Buildings 116, 104-113, 2016 | 145 | 2016 |
Investigation of a coupled geothermal cooling system with earth tube and solar chimney Y Yu, H Li, F Niu, D Yu Applied energy 114, 209-217, 2014 | 120 | 2014 |
Development, evaluation, and demonstration of a virtual refrigerant charge sensor H Li, JE Braun Hvac&R Research 15 (1), 117-136, 2009 | 105 | 2009 |
An improved decision tree-based fault diagnosis method for practical variable refrigerant flow system using virtual sensor-based fault indicators G Li, H Chen, Y Hu, J Wang, Y Guo, J Liu, H Li, R Huang, H Lv, J Li Applied Thermal Engineering 129, 1292-1303, 2018 | 99 | 2018 |
A statistical training data cleaning strategy for the PCA-based chiller sensor fault detection, diagnosis and data reconstruction method Y Hu, H Chen, G Li, H Li, R Xu, J Li Energy and Buildings 112, 270-278, 2016 | 99 | 2016 |
Data partitioning and association mining for identifying VRF energy consumption patterns under various part loads and refrigerant charge conditions G Li, Y Hu, H Chen, H Li, M Hu, Y Guo, J Liu, S Sun, M Sun Applied energy 185, 846-861, 2017 | 98 | 2017 |
Investigation on soil thermal saturation and recovery of an earth to air heat exchanger under different operation strategies F Niu, Y Yu, D Yu, H Li Applied Thermal Engineering 77, 90-100, 2015 | 90 | 2015 |
A sensor fault detection and diagnosis strategy for screw chiller system using support vector data description-based D-statistic and DV-contribution plots G Li, Y Hu, H Chen, H Li, M Hu, Y Guo, S Shi, W Hu Energy and Buildings 133, 230-245, 2016 | 89 | 2016 |
Feasibility study of a localized residential grey water energy-recovery system L Ni, SK Lau, H Li, T Zhang, JS Stansbury, J Shi, J Neal Applied Thermal Engineering 39, 53-62, 2012 | 85 | 2012 |
An enhanced PCA method with Savitzky-Golay method for VRF system sensor fault detection and diagnosis Y Guo, G Li, H Chen, Y Hu, H Li, L Xing, W Hu Energy and Buildings 142, 167-178, 2017 | 83 | 2017 |
Analysis of HVAC system oversizing in commercial buildings through field measurements D Woradechjumroen, Y Yu, H Li, D Yu, H Yang Energy and Buildings 69, 131-143, 2014 | 81 | 2014 |
A virtual supply airflow rate meter for rooftop air-conditioning units D Yu, H Li, M Yang Building and environment 46 (6), 1292-1302, 2011 | 80 | 2011 |
Apparatus and method for determining refrigerant charge level JE Braun, H Li US Patent 7,631,508, 2009 | 78 | 2009 |
An improved method for fault detection and diagnosis applied to packaged air conditioners H Li, JE Braun ASHRAE Transactions 109, 683, 2003 | 74 | 2003 |
Virtual in-situ calibration method in building systems Y Yu, H Li Automation in Construction 59, 59-67, 2015 | 73 | 2015 |