Microstructural characterization of normal and malignant human prostate tissue with vascular, extracellular, and restricted diffusion for cytometry in tumours magnetic … E Panagiotaki, RW Chan, N Dikaios, HU Ahmed, J O’Callaghan, ... Investigative radiology 50 (4), 218-227, 2015 | 244 | 2015 |
Temporal stability of adaptive 3D radial MRI using multidimensional golden means RW Chan, EA Ramsay, CH Cunningham, DB Plewes Magnetic Resonance in Medicine 61 (2), 354-363, 2009 | 233 | 2009 |
The influence of radial undersampling schemes on compressed sensing reconstruction in breast MRI RW Chan, EA Ramsay, EY Cheung, DB Plewes Magnetic Resonance in Medicine 67 (2), 363-377, 2012 | 135 | 2012 |
Dual-phase cardiac diffusion tensor imaging with strain correction CT Stoeck, A Kalinowska, C von Deuster, J Harmer, RW Chan, ... PloS one 9 (9), e107159, 2014 | 121 | 2014 |
Characterization and correction of eddy-current artifacts in unipolar and bipolar diffusion sequences using magnetic field monitoring RW Chan, C von Deuster, D Giese, CT Stoeck, J Harmer, AP Aitken, ... Journal of Magnetic Resonance 244, 74-84, 2014 | 45 | 2014 |
Quantitative CEST and MT at 1.5 T for monitoring treatment response in glioblastoma: early and late tumor progression during chemoradiation RW Chan, H Chen, S Myrehaug, EG Atenafu, GJ Stanisz, J Stewart, ... Journal of Neuro-Oncology 151, 267-278, 2021 | 38 | 2021 |
Accuracy and precision of apparent diffusion coefficient measurements on a 1.5 T MR-Linac in central nervous system tumour patients LSP Lawrence, RW Chan, H Chen, B Keller, J Stewart, M Ruschin, ... Radiotherapy and Oncology 164, 155-162, 2021 | 34 | 2021 |
High‐resolution diffusion tensor imaging of the human kidneys using a free‐breathing, multi‐slice, targeted field of view approach RW Chan, C Von Deuster, CT Stoeck, J Harmer, S Punwani, ... NMR in Biomedicine 27 (11), 1300-1312, 2014 | 34 | 2014 |
Optimised VERDICT MRI protocol for prostate cancer characterisation E Panagiotaki, A Ianus, E Johnston, R Chan, D Atkinson, D Alexander Proceedings of the 23rd meeting of the International Society for Magnetic …, 2015 | 31 | 2015 |
Chemical exchange saturation transfer MRI in central nervous system tumours on a 1.5 T MR-Linac RW Chan, LSP Lawrence, RT Oglesby, H Chen, J Stewart, A Theriault, ... Radiotherapy and Oncology 162, 140-149, 2021 | 26 | 2021 |
Using the robust principal component analysis algorithm to remove RF spike artifacts from MR images AE Campbell‐Washburn, D Atkinson, Z Nagy, RW Chan, O Josephs, ... Magnetic resonance in medicine 75 (6), 2517-2525, 2016 | 25 | 2016 |
High grade glioma radiation therapy on a high field 1.5 Tesla MR-Linac-workflow and initial experience with daily adapt-to-position (ATP) MR guidance: A first report CL Tseng, H Chen, J Stewart, AZ Lau, RW Chan, LSP Lawrence, ... Frontiers in Oncology 12, 1060098, 2022 | 21 | 2022 |
International Multi-institutional Patterns of Contouring Practice and Clinical Target Volume Recommendations for Stereotactic Body Radiation Therapy for Non-Spine Bone Metastases TK Nguyen, L Chin, A Sahgal, R Dagan, W Eppinga, M Guckenberger, ... International Journal of Radiation Oncology* Biology* Physics 112 (2), 351-360, 2022 | 19 | 2022 |
Chemical Exchange Saturation Transfer MRI for Differentiating Radiation Necrosis From Tumor Progression in Brain Metastasis—Application in a Clinical Setting H Mehrabian, RW Chan, A Sahgal, H Chen, A Theriault, WW Lam, ... Journal of Magnetic Resonance Imaging 57 (6), 1713-1725, 2023 | 16 | 2023 |
In vivo myofibre architecture in the systemic right ventricle J Harmer, K Pushparajah, N Toussaint, CT Stoeck, R Chan, D Atkinson, ... European heart journal 34 (47), 3640-3640, 2013 | 15 | 2013 |
Removing undersampling artifacts in DCE‐MRI studies using independent components analysis AL Martel, RW Chan, E Ramsay, DB Plewes Magnetic Resonance in Medicine 59 (4), 874-884, 2008 | 15 | 2008 |
Evolving concepts in margin strategies and adaptive radiotherapy for glioblastoma: A new future is on the horizon CL Tseng, KL Zeng, EA Mellon, SG Soltys, M Ruschin, AZ Lau, NS Lutsik, ... Neuro-Oncology 26 (Supplement_1), S3-S16, 2024 | 14 | 2024 |
Evaluating the accuracy of multicomponent T2 parameters for luminal water imaging of the prostate with acceleration using inner‐volume 3D GRASE RW Chan, AZ Lau, G Detzler, V Thayalasuthan, RK Nam, MA Haider Magnetic resonance in medicine 81 (1), 466-476, 2019 | 13 | 2019 |
Quantification of pulsed saturation transfer at 1.5 T and 3T RW Chan, S Myrehaug, GJ Stanisz, A Sahgal, AZ Lau Magnetic resonance in medicine 82 (5), 1684-1699, 2019 | 12 | 2019 |
Diffusion-weighted imaging on an MRI-linear accelerator to identify adversely prognostic tumour regions in glioblastoma during chemoradiation LSP Lawrence, RW Chan, H Chen, J Stewart, M Ruschin, A Theriault, ... Radiotherapy and Oncology 188, 109873, 2023 | 10 | 2023 |