Sledovať
Dr. Jun Liao
Názov
Citované v
Citované v
Rok
Effects of decellularization on the mechanical and structural properties of the porcine aortic valve leaflet
J Liao, EM Joyce, MS Sacks
Biomaterials 29 (8), 1065-1074, 2008
3902008
Fabrication of cardiac patch with decellularized porcine myocardial scaffold and bone marrow mononuclear cells
B Wang, A Borazjani, M Tahai, AL de Jongh Curry, DT Simionescu, ...
Journal of biomedical materials research Part A 94 (4), 1100-1110, 2010
2222010
Stabilized collagen scaffolds for heart valve tissue engineering
ME Tedder, J Liao, B Weed, C Stabler, H Zhang, A Simionescu, ...
Tissue Engineering Part A 15 (6), 1257-1268, 2009
2012009
Altered structural and mechanical properties in decellularized rabbit carotid arteries
C Williams, J Liao, EM Joyce, B Wang, JB Leach, MS Sacks, JY Wong
Acta biomaterialia 5 (4), 993-1005, 2009
1892009
Time-dependent biaxial mechanical behavior of the aortic heart valve leaflet
JA Stella, J Liao, MS Sacks
Journal of biomechanics 40 (14), 3169-3177, 2007
1822007
Hierarchical multiscale structure–property relationships of the red-bellied woodpecker (Melanerpes carolinus) beak
N Lee, MF Horstemeyer, H Rhee, B Nabors, J Liao, LN Williams
Journal of The Royal Society Interface 11 (96), 20140274, 2014
1682014
The stimulation of the cardiac differentiation of mesenchymal stem cells in tissue constructs that mimic myocardium structure and biomechanics
J Guan, F Wang, Z Li, J Chen, X Guo, J Liao, NI Moldovan
Biomaterials 32 (24), 5568-5580, 2011
1682011
A structural basis for the size-related mechanical properties of mitral valve chordae tendineae
J Liao, I Vesely
Journal of biomechanics 36 (8), 1125-1133, 2003
1552003
The relation between collagen fibril kinematics and mechanical properties in the mitral valve anterior leaflet
J Liao, L Yang, J Grashow, MS Sacks
1532007
Planar biaxial creep and stress relaxation of the mitral valve anterior leaflet
JS Grashow, MS Sacks, J Liao, AP Yoganathan
Annals of biomedical engineering 34, 1509-1518, 2006
1442006
Molecular orientation of collagen in intact planar connective tissues under biaxial stretch
J Liao, L Yang, J Grashow, MS Sacks
Acta biomaterialia 1 (1), 45-54, 2005
1302005
Myocardial scaffold-based cardiac tissue engineering: application of coordinated mechanical and electrical stimulations
B Wang, G Wang, F To, JR Butler, A Claude, RM McLaughlin, LN Williams, ...
Langmuir 29 (35), 11109-17, 2013
1232013
Functional collagen fiber architecture of the pulmonary heart valve cusp
EM Joyce, J Liao, FJ Schoen, JE Mayer Jr, MS Sacks
The Annals of thoracic surgery 87 (4), 1240-1249, 2009
1162009
In-situ deformation of the aortic valve interstitial cell nucleus under diastolic loading
HYS Huang, J Liao, MS Sacks
1122007
Differences in tissue-remodeling potential of aortic and pulmonary heart valve interstitial cells
WD Merryman, J Liao, A Parekh, JE Candiello, H Lin, MS Sacks
Tissue engineering 13 (9), 2281-2289, 2007
1102007
Mussel-inspired bioadhesives in healthcare: design parameters, current trends, and future perspectives
N Pandey, LF Soto-Garcia, J Liao, P Zimmern, KT Nguyen, Y Hong
Biomaterials science 8 (5), 1240-1255, 2020
1082020
Assembly and testing of stem cell-seeded layered collagen constructs for heart valve tissue engineering
ME Tedder, A Simionescu, J Chen, J Liao, DT Simionescu
Tissue engineering part A 17 (1-2), 25-36, 2011
1052011
Structural and biomechanical characterizations of porcine myocardial extracellular matrix
B Wang, ME Tedder, CE Perez, G Wang, AL de Jongh Curry, F To, ...
Journal of Materials Science: Materials in Medicine 23, 1835-1847, 2012
1042012
Tissue-to-cellular level deformation coupling in cell micro-integrated elastomeric scaffolds
JA Stella, J Liao, Y Hong, WD Merryman, WR Wagner, MS Sacks
Biomaterials 29 (22), 3228-3236, 2008
1012008
Regenerative Potential of Decellularized Porcine Nucleus Pulposus Hydrogel Scaffolds: Stem Cell Differentiation, Matrix Remodeling, and Biocompatibility Studies
JJ Mercuri, S Patnaik, G Dion, SS Gill, J Liao, DT Simionescu
Tissue Engineering Part A 19 (7-8), 952-966, 2013
912013
Systém momentálne nemôže vykonať operáciu. Skúste to neskôr.
Články 1–20