Cure of Fisher rats bearing radioresistant F98 glioma treated with cis-platinum and irradiated with monochromatic synchrotron X-rays MC Biston, A Joubert, JF Adam, H Elleaume, S Bohic, AM Charvet, ... Cancer research 64 (7), 2317-2323, 2004 | 246 | 2004 |
Synchrotron radiation-based experimental determination of the optimal energy for cell radiotoxicity enhancement following photoelectric effect on stable iodinated compounds S Corde, A Joubert, JF Adam, AM Charvet, JF Le Bas, F Esteve, ... British journal of cancer 91 (3), 544-551, 2004 | 173 | 2004 |
Prolonged survival of Fischer rats bearing F98 glioma after iodine-enhanced synchrotron stereotactic radiotherapy JF Adam, A Joubert, MC Biston, AM Charvet, M Peoc’h, JF Le Bas, ... International Journal of Radiation Oncology* Biology* Physics 64 (2), 603-611, 2006 | 147 | 2006 |
Photoactivation of gold nanoparticles for glioma treatment L Bobyk, M Edouard, P Deman, M Vautrin, K Pernet-Gallay, J Delaroche, ... Nanomedicine: Nanotechnology, Biology and Medicine 9 (7), 1089-1097, 2013 | 133 | 2013 |
Medical physics aspects of the synchrotron radiation therapies: Microbeam radiation therapy (MRT) and synchrotron stereotactic radiotherapy (SSRT) E Bräuer-Krisch, JF Adam, E Alagoz, S Bartzsch, J Crosbie, C DeWagter, ... Physica Medica 31 (6), 568-583, 2015 | 123 | 2015 |
Synchrotron radiation therapy of malignant brain glioma loaded with an iodinated contrast agent: first trial on rats bearing F98 gliomas JF Adam, H Elleaume, A Joubert, MC Biston, AM Charvet, J Balosso, ... International Journal of Radiation Oncology* Biology* Physics 57 (5), 1413-1426, 2003 | 122 | 2003 |
Efficacy of intracerebral delivery of cisplatin in combination with photon irradiation for treatment of brain tumors J Rousseau, RF Barth, M Fernandez, JF Adam, J Balosso, F Estève, ... Journal of neuro-oncology 98, 287-295, 2010 | 92 | 2010 |
Characterization of a synthetic single crystal diamond detector for dosimetry in spatially fractionated synchrotron x‐ray fields J Livingstone, AW Stevenson, DJ Butler, D Häusermann, JF Adam Medical physics 43 (7), 4283-4293, 2016 | 91 | 2016 |
Table-top water window transmission x-ray microscopy: Review of the key issues, and conceptual design of an instrument for biology JF Adam, JP Moy, J Susini Review of scientific instruments 76 (9), 2005 | 81 | 2005 |
Enhanced delivery of iodine for synchrotron stereotactic radiotherapy by means of intracarotid injection and blood–brain barrier disruption: Quantitative iodine biodistribution … JF Adam, MC Biston, A Joubert, AM Charvet, JF Le Bas, F Estève, ... International Journal of Radiation Oncology* Biology* Physics 61 (4), 1173-1182, 2005 | 76 | 2005 |
Monochromatic minibeams radiotherapy: from healthy tissue-sparing effect studies toward first experimental glioma bearing rats therapy P Deman, M Vautrin, M Edouard, V Stupar, L Bobyk, R Farion, ... International Journal of Radiation Oncology* Biology* Physics 82 (4), e693-e700, 2012 | 74 | 2012 |
Synchrotron photoactivation of cisplatin elicits an extra number of DNA breaks that stimulate RAD51-mediated repair pathways S Corde, J Balosso, H Elleaume, M Renier, A Joubert, MC Biston, ... Cancer research 63 (12), 3221-3227, 2003 | 71 | 2003 |
Dosimetry protocol for the forthcoming clinical trials in synchrotron stereotactic radiation therapy (SSRT) Y Prezado, M Vautrin, I Martínez‐Rovira, A Bravin, F Estève, H Elleaume, ... Medical physics 38 (3), 1709-1717, 2011 | 65 | 2011 |
Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements C Boudou, I Troprès, J Rousseau, L Lamalle, JF Adam, F Estève, ... Physics in Medicine & Biology 52 (16), 4881, 2007 | 65 | 2007 |
Absolute cerebral blood volume and blood flow measurements based on synchrotron radiation quantitative computed tomography JF Adam, H Elleaume, GL Duc, S Corde, AM Charvet, I Troprès, JFL Bas, ... Journal of Cerebral Blood Flow & Metabolism 23 (4), 499-512, 2003 | 62 | 2003 |
Ultra high dose rate Synchrotron Microbeam Radiation Therapy. Preclinical evidence in view of a clinical transfer L Eling, A Bouchet, C Nemoz, V Djonov, J Balosso, J Laissue, ... Radiotherapy and Oncology 139, 56-61, 2019 | 59 | 2019 |
Preclinical radiotherapy at the Australian Synchrotron's Imaging and Medical Beamline: instrumentation, dosimetry and a small-animal feasibility study J Livingstone, JF Adam, JC Crosbie, CJ Hall, JE Lye, J McKinlay, ... Synchrotron Radiation 24 (4), 854-865, 2017 | 48 | 2017 |
Treatment plans optimization for contrast‐enhanced synchrotron stereotactic radiotherapy M Edouard, D Broggio, Y Prezado, F Estève, H Elleaume, JF Adam Medical physics 37 (6Part1), 2445-2456, 2010 | 47 | 2010 |
Heavy element enhanced synchrotron stereotactic radiotherapy as a promising brain tumour treatment JF Adam, MC Biston, J Rousseau, C Boudou, AM Charvet, J Balosso, ... Physica Medica 24 (2), 92-97, 2008 | 45 | 2008 |
High-resolution blood–brain barrier permeability and blood volume imaging using quantitative synchrotron radiation computed tomography: study on an F98 rat brain glioma JF Adam, C Nemoz, A Bravin, S Fiedler, S Bayat, S Monfraix, G Berruyer, ... Journal of Cerebral Blood Flow & Metabolism 25 (2), 145-153, 2005 | 45 | 2005 |