Följ
Touko Kaasalainen
Touko Kaasalainen
Medical Physicist, HUS Medical Imaging Center, Helsinki, Finland
Verifierad e-postadress på hus.fi
Titel
Citeras av
Citeras av
År
Dental cone beam CT: A review
T Kiljunen, T Kaasalainen, A Suomalainen, M Kortesniemi
Physica Medica 31 (8), 844-860, 2015
2612015
Dental cone beam CT: An updated review
T Kaasalainen, M Ekholm, T Siiskonen, M Kortesniemi
Physica Medica 88, 193-217, 2021
1452021
Effect of patient centering on patient dose and image noise in chest CT
T Kaasalainen, K Palmu, V Reijonen, M Kortesniemi
American journal of roentgenology 203 (1), 123-130, 2014
1252014
Lens dose in routine head CT: comparison of different optimization methods with anthropomorphic phantoms
U Nikupaavo, T Kaasalainen, V Reijonen, SM Ahonen, M Kortesniemi
American journal of roentgenology 204 (1), 117-123, 2015
1152015
Effect of vertical positioning on organ dose, image noise and contrast in pediatric chest CT—phantom study
T Kaasalainen, K Palmu, A Lampinen, M Kortesniemi
Pediatric radiology 43, 673-684, 2013
572013
Cardiovascular magnetic resonance findings in patients with PRKAG2 gene mutations
P Pöyhönen, A Hiippala, L Ollila, T Kaasalainen, H Hänninen, T Heliö, ...
Journal of Cardiovascular Magnetic Resonance 17 (1), 89, 2015
452015
Limiting CT radiation dose in children with craniosynostosis: phantom study using model-based iterative reconstruction
T Kaasalainen, K Palmu, A Lampinen, V Reijonen, J Leikola, R Kivisaari, ...
Pediatric radiology 45, 1544-1553, 2015
442015
Fetal radiation dose in three common CT examinations during pregnancy–Monte Carlo study
A Kelaranta, T Mäkelä, T Kaasalainen, M Kortesniemi
Physica Medica 43, 199-206, 2017
392017
MRI with cardiac pacing devices–Safety in clinical practice
T Kaasalainen, S Pakarinen, S Kivistö, M Holmström, H Hänninen, ...
European Journal of Radiology 83 (8), 1387-1395, 2014
352014
Fetal radiation dose in computed tomography
A Kelaranta, T Kaasalainen, R Seuri, P Toroi, M Kortesniemi
Radiation protection dosimetry 165 (1-4), 226-230, 2015
312015
Clinical experience of magnetic resonance imaging in patients with cardiac pacing devices: unrestricted patient population
AM Vuorinen, S Pakarinen, I Jaakkola, M Holmström, S Kivistö, ...
Acta Radiologica 60 (11), 1414-1421, 2019
302019
Cardiac magnetic resonance imaging reveals frequent myocardial involvement and dysfunction in active rheumatoid arthritis
M Holmström, R Koivuniemi, K Korpi, T Kaasalainen, M Laine, A Kuuliala, ...
Clin Exp Rheumatol 34 (3), 416-23, 2016
302016
Radiation doses to staff in a hybrid operating room: an anthropomorphic phantom study with active electronic dosimeters
JS Santos, J Uusi-Simola, T Kaasalainen, P Aho, M Venermo
European Journal of Vascular and Endovascular Surgery 59 (4), 654-660, 2020
262020
Synthesis and in vitro phantom NMR and MRI studies of fully organic free radicals, TEEPO-glucose and TEMPO-glucose, potential contrast agents for MRI
M Soikkeli, K Sievänen, J Peltonen, T Kaasalainen, M Timonen, ...
Rsc Advances 5 (20), 15507-15510, 2015
232015
Magnetic resonance imaging safety in patients with abandoned or functioning epicardial pacing leads
AM Vuorinen, R Paakkanen, J Karvonen, J Sinisalo, M Holmström, ...
European radiology 32 (6), 3830-3838, 2022
212022
Cardiac MRI in patients with cardiac pacemakers: practical methods for reducing susceptibility artifacts and optimizing image quality
T Kaasalainen, S Kivistö, M Holmström, J Peltonen, S Pakarinen, ...
Acta Radiologica 57 (2), 178-187, 2016
202016
Peak flow measurements in patients with severe aortic stenosis: a prospective comparative study between cardiovascular magnetic resonance 2D and 4D flow and transthoracic …
R Hälvä, SM Vaara, JI Peltonen, TT Kaasalainen, M Holmström, J Lommi, ...
Journal of Cardiovascular Magnetic Resonance 23 (1), 132, 2021
192021
The effect of vertical centering and scout direction on automatic tube voltage selection in chest CT: a preliminary phantom study on two different CT equipments
T Kaasalainen, T Mäkelä, M Kortesniemi
European journal of radiology open 6, 24-32, 2019
192019
Ejection fraction in myocardial perfusion imaging assessed with a dynamic phantom: comparison between IQ-SPECT and LEHR
E Hippeläinen, T Mäkelä, T Kaasalainen, E Kaleva
EJNMMI physics 4, 1-14, 2017
182017
A phantom study comparing technical image quality of five breast tomosynthesis systems
VM Sundell, M Jousi, K Hukkinen, R Blanco, T Mäkelä, T Kaasalainen
Physica Medica 63, 122-130, 2019
152019
Systemet kan inte utföra åtgärden just nu. Försök igen senare.
Artiklar 1–20