CMOS neurostimulation ASIC with 100 channels, scaleable output, and bidirectional radio-frequency telemetry GJ Suaning, NH Lovell IEEE Transactions on Biomedical Engineering 48 (2), 248-260, 2001 | 303 | 2001 |
Substrate dependent stability of conducting polymer coatings on medical electrodes RA Green, RT Hassarati, L Bouchinet, CS Lee, GLM Cheong, FY Jin, ... Biomaterials 33 (25), 5875-5886, 2012 | 242 | 2012 |
Fabrication of implantable microelectrode arrays by laser cutting of silicone rubber and platinum foil M Schuettler, S Stiess, BV King, GJ Suaning Journal of neural engineering 2 (1), S121, 2005 | 207 | 2005 |
Simulating prosthetic vision: I. Visual models of phosphenes SC Chen, GJ Suaning, JW Morley, NH Lovell Vision research 49 (12), 1493-1506, 2009 | 205 | 2009 |
Performance of conducting polymer electrodes for stimulating neuroprosthetics RA Green, PB Matteucci, RT Hassarati, B Giraud, CWD Dodds, S Chen, ... Journal of neural engineering 10 (1), 016009, 2013 | 155 | 2013 |
Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants RGH Wilke, GK Moghadam, NH Lovell, GJ Suaning, S Dokos Journal of neural engineering 8 (4), 046016, 2011 | 133 | 2011 |
Direct activation and temporal response properties of rabbit retinal ganglion cells following subretinal stimulation D Tsai, JW Morley, GJ Suaning, NH Lovell Journal of neurophysiology 102 (5), 2982-2993, 2009 | 127 | 2009 |
Focal activation of the feline retina via a suprachoroidal electrode array YT Wong, SC Chen, JM Seo, JW Morley, NH Lovell, GJ Suaning Vision research 49 (8), 825-833, 2009 | 124 | 2009 |
Method for fabrication of hermetic electrical conductor feedthroughs GJ Suaning US Patent 7,818,876, 2010 | 121 | 2010 |
Bionic vision: system architectures–a review T Guenther, NH Lovell, GJ Suaning Expert review of medical devices 9 (1), 33-48, 2012 | 103 | 2012 |
A study in the mechanical milling of alumina powder CB Reid, JS Forrester, HJ Goodshaw, EH Kisi, GJ Suaning Ceramics International 34 (6), 1551-1556, 2008 | 102 | 2008 |
Evaluation of stimulus parameters and electrode geometry for an effective suprachoroidal retinal prosthesis MN Shivdasani, CD Luu, R Cicione, JB Fallon, PJ Allen, J Leuenberger, ... Journal of neural engineering 7 (3), 036008, 2010 | 100 | 2010 |
Current steering in retinal stimulation via a quasimonopolar stimulation paradigm PB Matteucci, SC Chen, D Tsai, CWD Dodds, S Dokos, JW Morley, ... Investigative ophthalmology & visual science 54 (6), 4307-4320, 2013 | 99 | 2013 |
Retinal neurostimulator for a multifocal vision prosthesis YT Wong, N Dommel, P Preston, LE Hallum, T Lehmann, NH Lovell, ... IEEE Transactions on Neural Systems and Rehabilitation Engineering 15 (3 …, 2007 | 98 | 2007 |
Attaining higher resolution visual prosthetics: a review of the factors and limitations CD Eiber, NH Lovell, GJ Suaning Journal of neural engineering 10 (1), 011002, 2013 | 92 | 2013 |
Visual acuity measurement of prosthetic vision: a virtual-reality simulation study SC Chen, LE Hallum, NH Lovell, GJ Suaning Journal of neural engineering 2 (1), S135, 2005 | 89 | 2005 |
Laser patterning of platinum electrodes for safe neurostimulation RA Green, PB Matteucci, CWD Dodds, J Palmer, WF Dueck, RT Hassarati, ... Journal of neural engineering 11 (5), 056017, 2014 | 78 | 2014 |
Simulating prosthetic vision: II. Measuring functional capacity SC Chen, GJ Suaning, JW Morley, NH Lovell Vision research 49 (19), 2329-2343, 2009 | 78 | 2009 |
In vitro biocompatibility of various polymer-based microelectrode arrays for retinal prosthesis SH Bae, JH Che, JM Seo, J Jeong, ET Kim, SW Lee, K Koo, GJ Suaning, ... Investigative ophthalmology & visual science 53 (6), 2653-2657, 2012 | 74 | 2012 |
The bionic eye (electronic visual prosthesis): A review GJ Suaning, NH Lovell, K Schindhelm, MT Coroneo Australian and New Zealand journal of ophthalmology 26 (3), 195-202, 1998 | 68 | 1998 |