Internal mechanical conditions in the soft tissues of a residual limb of a trans-tibial amputee S Portnoy, Z Yizhar, N Shabshin, Y Itzchak, A Kristal, Y Dotan-Marom, ... Journal of biomechanics 41 (9), 1897-1909, 2008 | 196 | 2008 |
Stress relaxation of porcine gluteus muscle subjected to sudden transverse deformation as related to pressure sore modeling A Palevski, I Glaich, S Portnoy, E Linder-Ganz, A Gefen | 141 | 2006 |
Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting S Portnoy, G Yarnitzky, Z Yizhar, A Kristal, U Oppenheim, I Siev-Ner, ... Annals of biomedical engineering 35, 120-135, 2007 | 108 | 2007 |
Design of a free-floating polycarbonate-urethane meniscal implant using finite element modeling and experimental validation JJ Elsner, S Portnoy, G Zur, F Guilak, A Shterling, E Linder-Ganz | 103 | 2010 |
The association of ankle dorsiflexion range of motion with hip and knee kinematics during the lateral step-down test A Rabin, S Portnoy, Z Kozol Journal of orthopaedic & sports physical therapy 46 (11), 1002-1009, 2016 | 97 | 2016 |
Patient-specific analyses of deep tissue loads post transtibial amputation in residual limbs of multiple prosthetic users S Portnoy, I Siev-Ner, N Shabshin, A Kristal, Z Yizhar, A Gefen Journal of biomechanics 42 (16), 2686-2693, 2009 | 90 | 2009 |
Surgical and morphological factors that affect internal mechanical loads in soft tissues of the transtibial residuum S Portnoy, I Siev-Ner, Z Yizhar, A Kristal, N Shabshin, A Gefen Annals of biomedical engineering 37, 2583-2605, 2009 | 77 | 2009 |
Outdoor dynamic subject-specific evaluation of internal stresses in the residual limb: hydraulic energy-stored prosthetic foot compared to conventional energy-stored prosthetic … S Portnoy, A Kristal, A Gefen, I Siev-Ner Gait & posture 35 (1), 121-125, 2012 | 75 | 2012 |
Real-time subject-specific analyses of dynamic internal tissue loads in the residual limb of transtibial amputees S Portnoy, J van Haare, RPJ Geers, A Kristal, I Siev-Ner, HAM Seelen, ... Medical engineering & physics 32 (4), 312-323, 2010 | 48 | 2010 |
MRI-based characterization of bone anatomy in the human knee for size matching of a medial meniscal implant JJ Elsner, S Portnoy, F Guilak, A Shterling, E Linder-Ganz | 46 | 2010 |
The correlation between upper extremity musculoskeletal symptoms and joint kinematics, playing habits and hand span during playing among piano students Y Kaufman-Cohen, S Portnoy, R Sopher, L Mashiach, L Baruch-Halaf, ... PloS one 13 (12), e0208788, 2018 | 40 | 2018 |
Hemorrhagic versus ischemic stroke: Who can best benefit from blended conventional physiotherapy with robotic-assisted gait therapy? F Dierick, M Dehas, JL Isambert, S Injeyan, AF Bouche, Y Bleyenheuft, ... PloS one 12 (6), e0178636, 2017 | 39 | 2017 |
The association between visual assessment of quality of movement and three-dimensional analysis of pelvis, hip, and knee kinematics during a lateral step down test A Rabin, S Portnoy, Z Kozol The Journal of Strength & Conditioning Research 30 (11), 3204-3211, 2016 | 38 | 2016 |
Postural control of individuals with chronic stroke compared to healthy participants: Timed-Up-and-Go, Functional Reach Test and center of pressure movement S Portnoy, S Reif, T Mendelboim, D Rand Eur J Phys Rehabil Med 53 (5), 685-93, 2017 | 37 | 2017 |
Visuomotor behaviors and performance in a dual-task paradigm with and without vibrotactile feedback when using a myoelectric controlled hand E Raveh, J Friedman, S Portnoy Assistive Technology 30 (5), 274-280, 2018 | 34 | 2018 |
Adding vibrotactile feedback to a myoelectric-controlled hand improves performance when online visual feedback is disturbed E Raveh, S Portnoy, J Friedman Human movement science 58, 32-40, 2018 | 33 | 2018 |
Effects of sitting postures on risks for deep tissue injury in the residuum of a transtibial prosthetic-user: a biomechanical case study S Portnoy, I Siev-Ner, N Shabshin, A Gefen Computer methods in biomechanics and biomedical engineering 14 (11), 1009-1019, 2011 | 33 | 2011 |
Automated 3D-printed finger orthosis versus manual orthosis preparation by occupational therapy students: Preparation time, product weight, and user satisfaction S Portnoy, N Barmin, M Elimelech, B Assaly, S Oren, R Shanan, ... Journal of Hand Therapy 33 (2), 174-179, 2020 | 32 | 2020 |
Myoelectric prosthesis users improve performance time and accuracy using vibrotactile feedback when visual feedback is disturbed E Raveh, S Portnoy, J Friedman Archives of physical medicine and rehabilitation 99 (11), 2263-2270, 2018 | 32 | 2018 |
Prevention of genu recurvatum in poststroke patients using a hinged soft knee orthosis S Portnoy, A Frechtel, E Raveh, I Schwartz PM&R 7 (10), 1042-1051, 2015 | 30 | 2015 |